A solid phase extraction (SPE) method was optimized for the quantitative analysis of perfluorooctanoic acid (PFOA) in serum using hydrophilic-lipophilic balance SPE and LC-MS/MS. Fetal bovine serums spiked with $^{13}C_8$-PFOA before or after SPE were used as test samples for evaluation of the SPE efficiency. Simultaneous evaluation of matrix effects and absolute SPE recovery for $^{13}C_8$-PFOA in serum using different sample pre-treatments and SPE conditions allowed optimization of SPE process efficiency with minimal matrix effect and decent SPE recovery. Introduction of protein precipitation as a sample pre-treatment procedure for serum samples before SPE generally decreased matrix effect in LC-MS/MS analysis and provided more stable recovery of PFOA.
Park, Deok-Hie;Youn, Yeu-Young;Choi, Jae-Won;Lim, Young-Hee;Cho, Hye-Sung
Mass Spectrometry Letters
/
제2권1호
/
pp.12-15
/
2011
The Korean government has regulated emission of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in waste water of manufacturing facilities producing chlorinated compounds since 2009. As this regulation is expected to be reinforced in 2013 to 50 pg I-TEQ/L, a large sample volume is required for the analysis of trace amounts of PCDD/Fs in waste water. Liquid-liquid extraction (LLE) is used to extract PCDD/Fs from aqueous samples; however, its low efficiency makes it inadequate for analyzing large sample volumes. Herein, we present a disk-type solid-phase extraction (SPE) method for the analysis of dioxin at a part per quadrillion level in waste water. This SPE system contains airtight glass covers with a decompression pump, which enables continuous semi-automated extraction. Small (0.5 L) and large (7 L) samples were extracted using LLE and SPE methods, respectively. The method detection limits (MDLs) were 0.001.0.25 and 0.015.4.1 pg I-TEQ/L for the SPE and LLE methods, respectively. The concentrations of detected congeners with both methods were similar. However, the concentrations of several congeners that were not detected with the LLE method were quantified using the SPE method.
An analytical method based on solid-phase extraction and gas chromatography / mass spectrometry has been developed for measurement of acaricides (amitraz, bromopropylate, coumaphos, cymiazole, and tetradifon) in honey sample. In the stability test of acaricides in honey, amitraz underwent a rapid degradation into 2,4-dimethylaniline (DMA), 2,4-dimethylphenylformamide (DMPF), and N-(2,4-dimethylphenyl)-N'-methylformamidine (DMPMF), whileas other acaricides were found to be stable even for over three months. Extraction of five acaricides from 5g of honey sample was carried out by liquid-liquid extraction using 20mL of ethylacetate. For purification, Florisil-SPE cartridge with elution of 5mL of n-hexane/ acetone (55:45, v/v) was found to remove interferences effectively. Quantification was performed using gas chromatography / mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery values from honey spiked at 0.02 and 0.20 ${\mu}g/g$ levels, respectively, were found to be greater than 75% for all acaricides. The method detection limits for acaricides were ranged from 0.1 to 3 ppb. The developed method in this study was applied for the monitoring of acaricides in honey products collected from urban markets in Korea.
The field of synthetic biology has emerged in response to the ongoing progress in the life sciences. Advances have been made in medicine, farming, eating, making materials, and more. Synthetic biology is the exploration of using living organisms to create new organisms. By manipulating specific genes to express targeted proteins, proteins can be created that are both productive and cost-effective. Solid-phase extraction (SPE) and liquid-liquid extraction (LLE) are employed for protein separation during the production process involving microorganisms. This study centers on Scanning Probe Microscopy (SPM) to showcase its utility in the food industry and food management. SPE is predominantly utilized as a pretreatment method to eliminate impurities from samples. In comparison to LLE, this method presents benefits such as decreased time and labor requirements, streamlined solvent extraction, automation capabilities, and compatibility with various other analytical instruments. Anion exchange chromatography (AEC) utilizes a similar methodology. Pharmaceutical companies utilize these technologies to improve the purity of biopharmaceuticals, thereby guaranteeing their quality. Used in the food and beverage industry to test chemical properties of raw materials and finished products. This exemplifies the potential of these technologies to enhance industrial development and broaden the scope of applications in synthetic biology.
본 연구는 지하수 중 라듐(226Ra) 분석을 위해 고상추출디스크(solid phase extraction disk)를 이용한 감마선분광분석법(이하 고상추출디스크법)을 제안하고 액체섬광계수기를 이용한 액체섬광계수(liquid scintillation counter, LSC)법 및 마리넬리비커(Marinelli beaker)를 이용한 감마선분광분석기(gamma ray spectrometer)법(이하 마리넬리비커법)과의 회수율 비교를 통해 적용성을 검토하였다. 226Ra을 회수한 고상추출디스크는 딸핵종의 방출을 방지하기 위해 폴리에틸렌 필름으로 밀봉 후 감마선분광분석기로 분석하였다. 24일 경과 후, 226Ra과 딸핵종인 214Bi과 214Pb이 방사평형 된 것으로 확인되었다. 라듐 표준물질을 이용하여 고상추출디스크법으로 분석한 딸핵종 214Bi와 214Pb의 회수율은 각각 80% (295.21 Kev)와 104% (351.92 Kev)로 액체섬광계수법보다 높게 나타났다. 바탕시료(blank) 측정시 감마선분광분석기 챔버내 질소를 주입했을 경우는 주입하지 않았을 경우보다 간섭치가 약 10% 이하로 낮아지는 것을 확인하였으며, 5 L 시료를 8만초 동안 측정한 검출한계는 0.17~0.40 pCi/L로 분석되어 미국 EPA 기준치인 1pCi/L를 만족하였다. 고상추출디스크법과 액체섬광계수법을 이용한 7개 지하수 시료 분석 결과, 두 방법의 상관계수(correlation coefficient)는 0.987로 나타나 추가적인 분석을 통해 통계적 유의성을 확보한다면 고상추출디스크법의 적용가능성이 높을 것으로 판단된다. 결과적으로, 고상추출디스크법을 이용한 지하수 중 226Ra 농도 분석은 전처리 과정이 비교적 단순하여 분석시간이 절약되고 높은 회수율과 낮은 검출한계치 등의 장점을 가지고 있는 것으로 분석되었다. 또한 고상추출디스크법은 액체섬광계수법과 마리넬리비커법에 비해 많은 양의 시료를 전처리하기 쉽기 때문에 저준위 시료 분석에 유용할 것으로 판단된다.
A multiple solid-phase extraction (SPE) method was used with liquid chromatography, coupled with mass spectrometry (LC/MS), for the analysis of heterocyclic amines (HCAs) in human urine. Separation efficiencies based on the pH of the mobile phase and the types of columns were compared. An amide column showed better baseline separation and narrower HCA peak widths at pH 5.0 for the mobile phase than a $C_8$ column. Each SPE step, HLB, MCX, and HybridSPE, was optimized by controlling the pH conditions. The combined method with the three SPEs effectively removed interfering species that cause ion-suppression during HCA detection. Validation of the method, performed with SIM and SRM detection, showed correlation coefficients above 0.991 in the range 0.3 - 16.7 ng/mL. Recovery rates were 45.4 - 97.3% on the $C_8$ column and 71.8 - 101.4% on the amide column, and method detection limits were 0.11 - 0.65 ng/mL on the $C_8$ column and 0.12 - 0.48 ng/mL on the amide column. This method using multiple SPEs offers significant benefits for high-throughput determination of HCAs in urine.
A new method for the simultaneous determination of heavy metal ions in cigarette material by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The cigarette material was digested by microwave digestion. Lead, cadmium, mercury, nickel and tin ions in the digested samples were pre-column derivatized with tetra-(2-chlorophenyl)-porphyrin ($T_2$-CPP) to form color chelates, which were then enriched by solid phase extraction with a $C_{18}$ cartridge. The chelates were separated on a Waters Xterra$^{TM}RP_{18}$ column by gradient elution with methanol (containing 0.05 mol/L pyrrolidine-aceticacid buffer salt, pH = 10.0) and acetone (containin0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0)as mobile phase at a flow rate of 0.5mL/min and analyzed with a photodiode array detector from 350-600 nm. The detection limits of lead, cadmium, mercury, nickel and tin were 4,3,3,8 and 5 ng/L, respectively, in the original samples. This method was afforded good results.
식품 중 HCAs을 검출하기 위한 최적 전처리 방법을 확립하기 위해 가열 조리된 돼지고기 패티를 이용하여 서로 다른 4가지 SPE(solid-phase extraction)방법을 비교하였다. 4가지 전처리 방법을 통해 얻은 15가지 HCAs 회수율은 3.0%(방법 A, Tri-P-1)-74.7%(방법A, Tri-P-2)이었다. 그 중 $MeA{\alpha}C$가 평균적으로 73.4%로 가장 높은 회수율을 보였으며 Tri-MeIQx가 15.2%의 가장 낮은 회수율을 보였다. 4가지 전처리 방법 중 방법A와 방법D가 가장 높은 회수율과 검출빈도를 보였으며 방법B와 방법C는 Harman(14.8%)을 제외하고는 전혀 검출되지 않았고 회수율을 구할 수 없었다 발암 가능 물질인 IQ, $A{\alpha}C$, $MeA{\alpha}C$, Glu-P-1, Glu-P-2, MeIQ, MeIQx, PhIP 등을 검출하는 방법에는 방법A(48.7-74.6%)가 4가지 방법 중 가장 유리하다. HCAs는 극성에 따라 polar amines과 less-polar amines으로 구분할 수 있는데 방법A는 less-polar amines검출에 유리하고 방법D는 polar amines검출에 유리하다. 방법A와 방법D의 chromatogram을 비교한 결과 방법A와 방법D 모두 15가지 HCAs가 깨끗하게 분리되었지만 Tri-MeIQx 등을 검출하는데 방법A가 더욱 유리하다. SPE 전처리 방법 및 LC/MS 분석방법에 대한 유효성을 확인하기 위해 LOD(0.2-2.1 ng/mL)와 LOQ(0.8-9.7 ng/mL), 표준 편차(0.2-8.6)를 구하였다.
Lima, Bruna R. De;Silva, Felipe M.A. Da;Koolen, Hector H.F.;Almeida, Richardson A. De;Souza, Afonso D.L. De
Mass Spectrometry Letters
/
제5권4호
/
pp.115-119
/
2014
The Brazil nut (Bertholletia excelsa - Lecythidaceae) is considered a product with high economic value, being a food widely appreciated for its nutritional qualities. Although previous studies have reported the biochemical composition of Brazil nut oil, the knowledge regarding the phospholipid composition exhibits a disagreement: the composition of fatty acids present in the structures of phospholipids is reported as being different from the composition of the free fatty acids present in the oil. In this work, solid phase extraction (SPE) was employed to provide a fast extraction of the phospholipids from Brazil nuts, in order to compare the phospholipid profile of the in nature nuts and their fatty acids precursor present in the oil. The major phospholipids were characterized by mass spectrometry approach. Their fragmentation pattern through direct infusion electrospray ionization ion-trap tandem mass spectrometry ($ESI-IT-MS^2$) proved to be useful to unequivocal characterization of these substances. High resolution (HR) experiments through ESI using a quadruple time of flight mass spectrometry (QTOF) system were performed to reinforce the identifications.
This paper reports a method using molecularly imprinted polymers that are grafted onto the surface of carboxyl-modified multi-walled carbon nanotubes as the solid-phase extraction adsorbents to detect Rhodamine B in chili powder samples. The polymers were characterized by FTIR and TGA. Various parameters which probably influence efficiency of extraction were optimized. The analytical parameters such as precision, accuracy and linear working range were also determined in optimal experimental conditions. And the proposed method was applied to analysis of Rhodamine B in chili powder samples. The limits of detection and quantification were 2.57 and 8.56 ${\mu}g/g$, respectively. The recoveries for analytes were higher than 95% and relative standard deviation values were found to be in the range of 0.83-4.15%. This method was successfully applied for the determination of Rhodamine B.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.