• 제목/요약/키워드: Solid phase cartridge

검색결과 98건 처리시간 0.024초

Application of On-Line SPE-LC/MSD to Measure Perfluorinated Compounds (PFCs) in Water (On-Line SPE-LC/MSD 시스템을 이용한 수중의 과불화 화합물(PFCs) 분석)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Jung, Jong-Moon;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제35권2호
    • /
    • pp.75-83
    • /
    • 2013
  • We applied a sensitive method based on on-line solid-phase extraction (SPE) and liquid chromatography/mass spectrometry (LC/MSD) using an electrospray interface for the determination of eleven perfluorinated compounds (PFCs) in water. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 mL water samples, recoveries were between $80.4{\pm}5.2%{\sim}109.5{\pm}1.4%$ and limit of quantification (LOQ) were 3.6~15.9 ng/L for the PFCs. The total PFCs concentrations of the tributaries and main stream of Nakdong River water samples were in the range of $8.0{\sim}678.6{\mu}g/L$.

Simultaneous Determination of Tin, Nickel, Lead, Cadmium and Mercury in Cigarette Material by Solid Phase Extraction and HPLC

  • Hu, Qun;Yang, Guangyu;Ma, Jing;Liu, Jikai
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권10호
    • /
    • pp.1433-1436
    • /
    • 2003
  • A new method for the simultaneous determination of heavy metal ions in cigarette material by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The cigarette material was digested by microwave digestion. Lead, cadmium, mercury, nickel and tin ions in the digested samples were pre-column derivatized with tetra-(2-chlorophenyl)-porphyrin ($T_2$-CPP) to form color chelates, which were then enriched by solid phase extraction with a $C_{18}$ cartridge. The chelates were separated on a Waters Xterra$^{TM}RP_{18}$ column by gradient elution with methanol (containing 0.05 mol/L pyrrolidine-aceticacid buffer salt, pH = 10.0) and acetone (containin0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0)as mobile phase at a flow rate of 0.5mL/min and analyzed with a photodiode array detector from 350-600 nm. The detection limits of lead, cadmium, mercury, nickel and tin were 4,3,3,8 and 5 ng/L, respectively, in the original samples. This method was afforded good results.

Determination of Pyribencarb and Its Metabolite KIE-9749 in Agricultural Commodities by High-Performance Liquid Chromatography (액체크로마토그래피를 이용한 농산물중 pyribencarb와 대사물 KIE-9749의 잔류 분석법)

  • Kwon, Hyeyoung;Hong, Su-Myeong;Kim, Taek-Kyum;Kim, Hyung-Jin;Moon, Byeong-Chul;Kyung, Kee-Sung
    • The Korean Journal of Pesticide Science
    • /
    • 제20권3호
    • /
    • pp.236-246
    • /
    • 2016
  • The aim of this study was to develop an analytical method for the determination of pyribencarb and its metabolite KIE-9749 in agricultural commodities. The experiment was performed with a range of concentrations $0.05{\sim}2.5{\mu}g/g$ in apple, green pepper, potato, hulled rice, soybean, pear, peach, grape and cucumber. Each samples were extracted with acetone and cleaned by dichloromethane/saline water partition and purified with Florisil solid phase extraction (SPE) cartridge and aminopropyl SPE cartridge. Pyribencarb and KIE-9749 were separated and quantified by HPLC/UVD at 265nm using acetonitrile and water as mobile phase. The recoveries of pyribencarb and KIE-9749 were within 78.3~108.4% and 73.9~113.7% with RSD below 12.2% and 15.0%, respectively. The limits of quantification (LOQ) were both $0.05{\mu}g/g$. LC/ESI-MS/MS was optimized for confirmation of residue identity.

Optimization of Automated Solid Phase Extraction-based Synthesis of [18F]Fluorocholine (고체상 추출법을 기반으로 한 [18F]Fluorocholine 합성법의 최적화 연구)

  • Jun Young PARK;Jeongmin SON;Won Jun KANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • 제55권4호
    • /
    • pp.261-268
    • /
    • 2023
  • [18F]Fluorocholine is a radiopharmaceutical used non-invasively in positron emission tomography to diagnose parathyroid adenoma, prostate cancer, and hepatocellular carcinoma by evaluating the choline metabolism. In this study, a radiolabeling method for [18F]fluorocholine was optimized using a solid phase extraction (SPE) cartridge. [18F]Fluorocholine was labeled in two steps using an automated synthesizer. In the first step, dibromomethane was reacted with [18F]KF/K2.2.2/K2CO3 to obtain the intermediate [18F]fluorobromomethane. In the second step, [18F]fluorobromomethane was passed through a Sep-Pak Silica SPE cartridge to remove the impurities and then reacted with N,N-dimethylaminoethanol (DMAE) in a Sep-Pak C18 SPE cartridge to label [18F]fluorocholine. The reaction conditions of [18F]fluorocholine were optimized. The synthesis yield was confirmed according to the number of silica cartridges and DMAE concentration. No statistically significant difference in the synthesis yield of [18F]fluorocholine was observed when using four or three silica cartridges (P>0.05). The labeling yield was 11.5±0.5% (N=4) when DMAE was used as its original solution. On the other hand, when diluted to 10% with dimethyl sulfoxide, the radiochemical yield increased significantly to 30.1±5.2% (N=20). In conclusion, [18F]Fluorocholine for clinical use can be synthesized stably in high yield by applying an optimized synthesis method.

Determination of Ursodeoxycholic Acid in Crude Drug Formulations by HPLC and SPE Using Selective Pre-column Derivatization with 2-Bromoacetyl-6-methoxynaphthalene (2-Bromoacetyl-6-methoxynaphthalene을 형광유도체화제로 HPLC와 SPE를 이용한 생약제제 중 Ursodeoxycholic acid의 정량)

  • 진창화;임수희;이기진;심형섭;조의환;염정록
    • YAKHAK HOEJI
    • /
    • 제46권6호
    • /
    • pp.392-397
    • /
    • 2002
  • A simple and sensitive high performance liquid chromatographic method to quantitate ursodeoxycholic acid in crude drug pharmaceuticals was investigated. Ursodeoxycholic acid react with 2-bromoacetyl-6-methoxynaphthalene (Br-AMN) in the presence of triethylamine to form highly fluorescent derivative. The derivatization procedure was performed at 7$0^{\circ}C$ and completed within 30 min. The optimal wavelength of the fluorescence detector are λ$_{ex}$=300 nm and λ$_{em}$ = 460 nm. The LOD of the ursodeoxycholic acid was 25 ng/mι based on the S/N =3, and the LOQ was 80 ng/mι based on S/N = 10. Crude drug pharmaceuticals pretreated by solid phase extraction (Sep-pak $C_{18}$ cartridge) which were shown very good separation and recovery values for the compound.d.

Determination of Acaricides in Honey by Solid-Phase Extraction and Gas Chromatography / Mass Spectrometry

  • Hong, Joo-Yeon;Jung, Ok-Sang;Ryoo, Jae-Jeong;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.61-66
    • /
    • 2009
  • An analytical method based on solid-phase extraction and gas chromatography / mass spectrometry has been developed for measurement of acaricides (amitraz, bromopropylate, coumaphos, cymiazole, and tetradifon) in honey sample. In the stability test of acaricides in honey, amitraz underwent a rapid degradation into 2,4-dimethylaniline (DMA), 2,4-dimethylphenylformamide (DMPF), and N-(2,4-dimethylphenyl)-N'-methylformamidine (DMPMF), whileas other acaricides were found to be stable even for over three months. Extraction of five acaricides from 5g of honey sample was carried out by liquid-liquid extraction using 20mL of ethylacetate. For purification, Florisil-SPE cartridge with elution of 5mL of n-hexane/ acetone (55:45, v/v) was found to remove interferences effectively. Quantification was performed using gas chromatography / mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery values from honey spiked at 0.02 and 0.20 ${\mu}g/g$ levels, respectively, were found to be greater than 75% for all acaricides. The method detection limits for acaricides were ranged from 0.1 to 3 ppb. The developed method in this study was applied for the monitoring of acaricides in honey products collected from urban markets in Korea.

Multisample Extraction system for Solid Phase Extraction of Dissolved Organic Compounds from Sea Water (해수로부터 용존 윤기물의 Solid Phase Extraction을 위한 다수 시료 처리 장치)

  • Cho Ki Woong;Jung Kyungwha;Shin Jongheon;Kim Suk Hyun;Hong Gi-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • 제3권3호
    • /
    • pp.34-40
    • /
    • 2000
  • A multisample extraction device was newly designed for efficient extraction of dissolved lipophillic organic compounds from sea water sample. This device allowed extraction of organic compounds from up to 96 sample at a time using 96 multifolder on the principle of solid phase extraction with commercially available octadecyl silane (ODS) cartridges. The recovery yield of the new divice was higher than 90 % while that of conventional liquid-liquid extraction process are only 60 - 70 %. The amount of solvent required for the new device could be reduced to less than 20㎖ per 1ℓ of sample while 1 - 2 ℓ of solvent were used in the conventional liquid-liquid extraction process. The usefulness of this novel method was demonstrated with sea water samples collected from Yellow sea, and the qualitative and quantitative analyses results of the dissolved hydrocarbon showed this method was superior to that of conventional liquid-liquid extraction process in efficiency and reliability.

  • PDF

New Analytical Method of Cyclosporine A in Human Serum by High -performance Liquid Chromatography/Diode Array Detector and Its Application to Pharmacokinetics of Cyclosporine A in Human Volunteers

  • Kim, Eun-Young;Chung, Yeon-Bok;Kwon, Oh-Seung
    • Proceedings of the PSK Conference
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.423.1-423.1
    • /
    • 2002
  • A simple. specific and sensitive method for the determination of cyclosporine A (CsA) in human serum has been developed by a high performance liquid chromatography/diode array detector (DAD) and applied to pharmacokinetic study of CsA. This method involves the use of solid phase extraction procedure following rapid protein precipitation with zinc sulphate from 1 $m\ell$ of human serum, using a disposable $C_{18}$ extraction cartridge. (omitted)

  • PDF

Simultaneous Determination of the Water Soluble Vitamins in Multi-Nutrient Tablets by Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Preventive Nutrition and Food Science
    • /
    • 제7권1호
    • /
    • pp.12-17
    • /
    • 2002
  • Simultaneous determination of nine water-soluble vitamins contained in multi-nutrient tablets was carried out by reversed phase high-performance liquid chromatography (RP-HPLC) equipped with analytical $C_{18}$ column and UV (270 nm) detector. Those standard vitamins were successfully separated within 23 minutes by gradient elution with solvent A (0.5 M potassium phosphate monobasic) and solvent B (0.25 M potassium phosphate monobasic-methanol, 1:1). Calibration curves showed good linealities with correlation coefficients (> 0.92) in tested ranged respectively. The detection limits were considered to be 2.1 ng for ascorbic acids 60 ng for Vit B$_{6}$ 3 ng for p-aminobenzoic acid, 9 ng for niacinamide, 9 ng for thiamin, 5.0 ng for folic acid and 1.5 ng for riboflavin at 0.05 a.u.f.s. Solid phase extraction through Sep-Pak (C$_{18}$ ) cartridge was successfully applied for purification of water soluble vitamins in commercial multi-nutrient tablets.ts.

Study on New Extraction Method of Microcystins from Cyanobacteria (남조류로부터 마이크로시스틴을 추출하는 새로운 추출법 연구)

  • Pyo, Dong Jin;Shin, Hyun Du
    • Journal of the Korean Chemical Society
    • /
    • 제45권2호
    • /
    • pp.149-155
    • /
    • 2001
  • A new analytical method of cyanobacterial toxins, i, e, microcysins was deveeloped using supercritical fluid extraction(SFE). The microcystins mcluded in the study are sparsely soluble in neat supercritical fluid CO$_2$ However, the microcystins were successfully extracted with a temary mixture(90% CO$_2$,9.0% methanol 1.0% water) at 40$^{\circ}$C and 250 atm. The SFE method developed in this study has several advantages over solid-phase extraction(SPE) sample preparation for the analysis of microcystins. Sample handling steps are minimized thus reducing possible losses of analytes and saving analysis time. No clean-up steps are employed in this SFE method. Althouhgh many methods have been described for microcystim RR and LR, the method using solid-phase extraction with ODS cartridges is the most commonly used. However, the adsorbing power of ODS caridges for microcystins is weak, so we have attempted to use a more polar CN cartridge, to increase the adsorbing power for microcystins. Lyophilized cells(100mg) were wxtracted with 5% (v/v) acetic acid. The extract was centrifuged and then the supernatant was applied to a CN cartridge. The cartridge which contained microcystins was rinsed with 5 ml of water and 5 ml of 0.5 M acetic acid. followed by 5 ml of 5% acetonitrile in water , and were determined by HPLC. Better recoveries and chromatogram were observed than with ODS cartridge.

  • PDF