• 제목/요약/키워드: Solid phase Extraction

검색결과 542건 처리시간 0.032초

A Study on the Analytical Methods Using Solid-phase Extraction for the Determination of Phenols in Water

  • Jeon, Chi-Wan;Lee, Jung-Hwa;Lee, Sang-Hak
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.135-138
    • /
    • 2003
  • Based on solid phase extraction, gas chromatography and mass spectrometry procedure for determining phenol and its derivatives in natural water was presented. In solid phase extraction, three types of techniques using solid phase adsorption material were treated with acid and salt, and converted second portion of acetyl derivatives. Under the these condition, extraction efficiency and detection ability dependent on extraction methods were discussed. Obtained results using optimized solid phase extraction techniques showed more convenience, simplifier and lower cost than the conventional analytical methods with holding wide dynamic range and lower detection limits.

  • PDF

Solid-Phase Extraction of Caffeine and Catechin Compounds from Green Tea by Caffeine Molecular Imprinted Polymer

  • Jin, Yinzhe;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권2호
    • /
    • pp.276-280
    • /
    • 2007
  • In this work, caffeine and some catechin compounds + C, EC, EGC, and EGCG were extracted from green tea by using molecular imprinted polymers (MIP) as sorbent materials in a solid-phase extraction (SPE) process known as MISPE (molecular imprinted solid-phase extraction). For synthesis of MIP, caffeine was employed as the template, MAA as the monomer, EGDMA as the crosslinker, and AIBN as the initiator. A solution of caffeine (0.2 mg/mL in methanol) was utilized in the solid extraction cartridges following loading, washing, and elution procedures with acetonitrile, methanol, and methanol-acetic acid (90/10, %v/v) as the solvents, respectively. This solid-phase extraction protocol was applied for the extraction of caffeine and some catechin compounds from green tea. A comparison was made between the results obtained with the MIP cartridges and a traditional C18 reversed-phase cartridge. It was thereupon found that the recovery of caffeine by the MIPbased sorbent used in this work was almost two and four times greater than that by a commercially available C18 material. A quantitative analysis was conducted by high performance liquid chromatography (HPLC) using a C18 column (5 μm, 250 × 4.6 mm) with methanol/water (40/60, %v/v) as the mobile phase at a flow rate of 0.5 mL/min.

생체시료로부터 미량 $\beta$-Blockers의 동시고상추출에 사용될 흡착제들의 특성 (Characterization of Adsorbents for the Simultaneous Solid-Phase Extraction of Trace $\beta$-Blockers from Biological Samples)

  • 김경례;김도정
    • 분석과학
    • /
    • 제6권4호
    • /
    • pp.375-381
    • /
    • 1993
  • 생체시료 중 ${\beta}$-blockers의 동시분석을 위한 시료 전처리 과정에서 고상추출법을 사용하기 위해 4가지 흡착제의 흡착 및 탈착 효율을 조사하였다. 용출 용매로서 methanol을 사용하였을 때 Chromosorb 107이 가장 높은 회수율을 보였다. ${\beta}$-Blockers의 breakthrough 조사를 하여 Chromosorb 107 컬럼의 우수한 흡착 및 탈착 성질을 혈청 중 2~8 ppm 농도 범위의 ${\beta}$-blockers를 동시에 고상추출하는 데 Chromosorb 107/methanol의 유용성을 조사하였다.

  • PDF

Solid Phase Micro Extraction을 이용한 산초의 휘발성 성분 분석 (Analysis of Volatile Components of Sancho(Zanthoxylum schinifolium)by Solid Phase Micro Extraction)

  • 장희진
    • 한국식품영양학회지
    • /
    • 제12권2호
    • /
    • pp.119-123
    • /
    • 1999
  • Test of the optimum condition of solid phase micro extraction(SPME) was performed by use of 5 vol-atile components in dilute aqueous solution. Volatile components of Sancho(Zanthoxylum schinifolium) were isolated by SPME method and were analyzed by GC/MSD and compared with volatile compone-nts isolated by simultaneous distillation extraction (SDE) method. Total 31 components were identified by comparing gas chromatography retention time and mass spectral data. The major compounds were limonene geranyl acetate $\beta$-phellandrene phellandral mycene linalool rose oxide caproic acid and caprylic acid SPME sampling procedure was found to be a good method for qualitative analysis of the volatile components.

  • PDF

물리적 가공법을 이용한 강황으로부터 Curcuminoid의 고체상추출 (Solid-Phase Extraction of Curcuminoid from Turmeric Using Physical Process Method)

  • 이광진;양혜진;정상원;마진열
    • 생약학회지
    • /
    • 제43권3호
    • /
    • pp.250-256
    • /
    • 2012
  • In order to extract the curcuminoid such as curcumin, demethoxycurcumin (DMC), and bisdemethoxycurcumin (BDMC) in turmeric (Curcuma longa), solvent extraction methods (dipping and ultrasonic extraction method) and solid-phase extraction (SPE) were used. RP-HPLC (reverse-phase high-performance liquid chromatography) and TLC (thin-layer chromatography) were used for identification and analysis the three curcuminoid. From the experimental results, it is evident that the percentage of curcuminoid extracted from turmeric by ultrasonic extraction method was higher than dipping method. The percentage of curcumin extracted from turmeric by pure methanol was higher than any aqueous methanolic composition. Moreover, the total peak area of three curcuminoid was above 92% in RP-HPLC using solid-phase extraction. These results will form a database for investigating the constituents of natural products and the resources of pharmaceutical, nutrition, and cosmetic products.

해수로부터 용존 윤기물의 Solid Phase Extraction을 위한 다수 시료 처리 장치 (Multisample Extraction system for Solid Phase Extraction of Dissolved Organic Compounds from Sea Water)

  • 조기웅;정경화;신종헌;김석현;홍기훈
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제3권3호
    • /
    • pp.34-40
    • /
    • 2000
  • 지용성 용존 유기물을 해수로부터 효율적으로 추출할 수 있는 고체상 추출 (solid phase extraction)장치를 새로이 고안하였다. 본 장치는 octadecyl silane (ODS) cartridge와 압력 평형 마개, 96 multifolder, 아스피레타 형 진공 펌프로 구성하였다. 본 장치는 기존의 액체-액체 추출법보다 회수 효율은 1.4 배 이상 증대시켰으며, 최소 시료량을 8 배 이상 감소 시켰다. 따라서 용매의 사용을 5 배 이상 감소시킬 수가 있으므로 나중에 사용된 용매를 제거하는 노력도 크게 감소시켰다. 뿐만 아니라 96 개의 시료(각 1ℓ)를 동시에 처리할 수 있으므로 지용성 용존 유기물의 추출 과정을 반자동화시킨 획기적인 장치이다. 본 장치를 통하여 황해 해수 시료에서 추출된 용존 탄화수소의 정성 및 정량 분석 결과 본 장치가 효율성과 신뢰성에서 기존의 액체-액체 추출법을 대체할 수 있을 것으로 사료된다.

  • PDF

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).

Molecularly Imprinted Polymers for Solid-Phase Extraction of Sarcosine as Prostate Cancer Biomarker from Human Urine

  • Hashemi-Moghaddam, Hamid;Rahimian, Majid;Niromand, Bahman
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2330-2334
    • /
    • 2013
  • A highly selective molecularly imprinted polymer (MIP) for sarcosine, a cancer marker, was prepared and its use as solid-phase extraction (SPE) sorbent material was demonstrated. The MIP was prepared by a very simple procedure using methacrylic acid as functional monomer and a mixture acetonitrile/water (4/1, v/v) as porogen, overcoming in this way the problems usually related to the imprinting of biological polar compounds. The MIP was tested in batch experiments in order to evaluate its binding properties and then used as SPE sorbent for the selective clean-up and pre-concentration of sarcosine. The extraction protocol was successfully applied to the direct extraction of sarcosine from spiked human urine indicating that the MIP allowed sarcosine to be pre-concentrated while simultaneously interfering compounds were removed from the matrix.