• 제목/요약/키워드: Solid Sulfur

검색결과 128건 처리시간 0.029초

Degradation of All-Solid-State Lithium-Sulfur Batteries with PEO-Based Composite Electrolyte

  • Lee, Jongkwan;Heo, Kookjin;Song, Young-Woong;Hwang, Dahee;Kim, Min-Young;Jeong, Hyejeong;Shin, Dong-Chan;Lim, Jinsub
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.199-207
    • /
    • 2022
  • Lithium-sulfur batteries (LSBs) have emerged as a promising alternative to lithium-ion batteries (LIBs) owing to their high energy density and economic viability. In addition, all-solid-state LSBs, which use solid-state electrolytes, have been proposed to overcome the polysulfide shuttle effect while improving safety. However, the high interfacial resistance and poor ionic conductivity exhibited by the electrode and solid-state electrolytes, respectively, are significant challenges in the development of these LSBs. Herein, we apply a poly (ethylene oxide) (PEO)-based composite solid-state electrolyte with oxide Li7La3Zr2O12 (LLZO) solid-state electrolyte in an all-solid-state LSB to overcome these challenges. We use an electrochemical method to evaluate the degradation of the all-solid-state LSB in accordance with the carbon content and loading weight within the cathode. The all-solid-state LSB, with sulfur-carbon content in a ratio of 3:3, exhibited a high initial discharge capacity (1386 mAh g-1), poor C-rate performance, and capacity retention of less than 50%. The all-solid-state LSB with a high loading weight exhibited a poor overall electrochemical performance. The factors influencing the electrochemical performance degradation were revealed through systematic analysis.

Preparation of rGO-S-CPEs Composite Cathode and Electrochemical Performance of All-Solid-State Lithium-Sulfur Battery

  • Chen, Fei;Zhang, Gang;Zhang, Yiluo;Cao, Shiyu;Li, Jun
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권3호
    • /
    • pp.362-368
    • /
    • 2022
  • The application of polymer composite electrolyte in all-solid-state lithium-sulfur battery (ASSLSBs) can guarantee high energy density and improve the interface contact between electrolyte and electrode, which has a broader application prospect. However, the inherent insulation of the sulfur-cathode leads to a low electron/ion transfer rate. Carbon materials with high electronic conductivity and electrolyte materials with high ionic conductivity are usually selected to improve the electron/ion conduction of the composite cathode. In this work, PEO-LiTFSI-LLZO composite polymer electrolyte (CPE) with high ionic conductivity was prepared. The ionic conductivity was 1.16×10-4 and 7.26×10-4 S cm-1 at 20 and 60℃, respectively. Meanwhile, the composite sulfur cathode was prepared with Sulfur, reduced graphene oxide and composite polymer electrolyte slurry (S-rGO-CPEs). In addition to improving the ion conductivity in the cathode, CPEs also replaces the role of binder. The influence of different contents of CPEs in the cathode material on the performance of the constructed battery was investigated. The results show that the electrochemical performance of the all-solid-state lithium-sulfur battery is the best when the content of the composite electrolyte in the cathode is 40%. Under the condition of 0.2C and 45℃, the charging and discharging capacity of the first cycle is 923 mAh g-1, and the retention capacity is 653 mAh g-1 after 50 cycles.

Degradation Mechanisms of a Li-S Cell using Commercial Activated Carbon

  • Norihiro Togasaki;Aiko Nakao;Akari Nakai;Fujio Maeda;Seiichi Kobayashi;Tetsuya Osaka
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.361-368
    • /
    • 2023
  • In lithium-sulfur (Li-S) batteries, encapsulation of sulfur in activated carbon (AC) materials is a promising strategy for preventing the dissolution of lithium polysulfide into electrolytes and enhancing cycle life, because instead of solid-liquid-solid reactions, quasi-solid-state (QSS) reactions occur in the AC micropores. While a high weight fraction of sulfur in S/AC composites is essential for achieving a high energy density of Li-S cells, the deterioration mechanisms under such conditions are still unclear. In this study, we report the deterioration mechanisms during charge-discharge cycling when the discharge products overflow from the AC. Analysis using scanning electron microscopy and energy-dispersive X-ray spectrometry confirms that the sulfur in the S/AC composites migrates outside the AC as cycling progresses, and it is barely present in the AC after 20 cycles, which corresponds to the capacity decay of the cell. Impedance analysis clearly shows that the electrical resistance of the S/AC composite and the charge-transfer resistance of QSS reactions significantly increase as a result of sulfur migration. On the other hand, the charge-discharge cycling performance under limited-capacity conditions, where the discharge products are encapsulated inside the AC, is extremely stable. These results reveal the degradation mechanism of a Li-S cell with micro-porous carbon and provide crucial insights into the design of a S/AC composite cathode and its operating conditions needed to achieve stable cycling performance.

분말형 및 액상형 개질유황의 첨가율에 따른 경량체의 밀도 및 흡수율 특성 (Density and Absorption Properties of the Lightweight Material According to the addition ratio of the Powdery and Liquid Type Modified Sulfur)

  • 이용;김헌태;배기선;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.158-159
    • /
    • 2015
  • Worldwide refinery industry is a large amount of sulfur is produced by development. what that sulfur, it is produced through the desulfurization process and sulfur recover process. And it is made with the liquid state or solid-state. Also, the trend for structure is being changed from wall construction to rhamen construction. The amount of lightweight panels uesd in rhamen construction is also increasing. Therefore, In this study, it is intended to study density and absorption rate of the blast furnace slag lightweight material by using a sulfur lowered melting point. The plain has highest density and the density is lower when adding modified sulfur more. The plain has the lowest absorption and the absorption is higher according to adding modified sulfur more.

  • PDF

황산화세균 Thiobacillus thiooxidans에 의한 fly ash의 중금속 제거 특성:고형물 농도의 영향 (Characterization of Heavy Metals Bioleaching from Fly Ash by a Sulfur-Oxidizing Bacterium Thiobacillus thiooxidans: Effect of Solid Concentrations)

  • 조경숙;문희선;이인숙
    • 환경생물
    • /
    • 제17권2호
    • /
    • pp.183-190
    • /
    • 1999
  • The bioleaching of heavy metals from fly ash was performed by Thiobacillus thiooxidans MET isolated from the enrichment culture of an anaerobically digested sludge. The effect of solid concentrations on the efficiency of metal leaching was studied in shaken flasks. In the range of solid concentrations 20 g.L­$^1$to 100 g.L­$^1$T. thiooxidans MET oxidized S$^{0}$ to sulfate without any lag period. The final pH of slurry solution was decreased to below pH 1, and the final oxide-redox potential (ORP) was increased to over 420 mV in the solid concentrations below 100 g.L­$^1$. However, the initial lag period of 4 to 8 days was required to obtain the pH reduction and ORP increase of the slurry solutions in the range of solid concentrations 150 g.L­$^1$to 300 g.L­$^1$. The sulfur oxidation rate of T. thiooxidans MET in 20~100 g.L­$^1$solid concentrations was 0.70~0.75 g-S.L­$^1$ㆍ d­$^1$, but its sulfur oxidation activity was remarkably inhibited with increasing solid concentration over 150 g.L­$^1$. Increasing fly ash solids concentration in the range of solids concentration 20 g.L­$^1$ to 200 g.L­$^1$decreased the removal efficiency of Zn, Cu, Mn, Cr and Pb. The solubilization of heavy metals from fly ash was strongly correlated with the pH value of slurry solution. When the pH of slurry solution was reduced to 3, the solubilization process of Zn, Cu and Mn started, and their solubilization efficiency of Zn, Cu and Mn was progressively increased below pH 2. However, the solubilization process of Cr and Pb started at pH 2.5 and 2.0, respectively.

  • PDF

Solid phase microextraction-gas chromatograph/pulsed flame photometric detector(SPME-GC/PFPD)와 static headspace-gas chromatograph/pulsed flame photometric detector(SH-GC/PEPD)를 이용한 황 함유 화합물들의 분석 방법 비교 (Comparison of Solid Phase Microextraction-Gas Chromatograph/Pulsed Flame Photometric Detector (SPME-GC/PFPD) and Static Headspace-Gas Chromatograph/Pulsed Flame Photometric Detector (SH-GC/PEPD) for the Analysis of Sulfur-Containing Compounds)

  • 양지연;김영석
    • 한국식품과학회지
    • /
    • 제37권5호
    • /
    • pp.695-701
    • /
    • 2005
  • 각각의 황 함유 화합물의 표준곡선을 그렸을 때, linear range의 범위는 $10^2$부터 $10^4$까지의 범위를 보였다. Dimethyl trisulfide가 가장 작은 limit of detection(LOD) 값과 가장 넓은 linear range $(10^4)$를 보이는 반면, methional은 가장 큰 LOD 값과 가장 좁은 linear range$(10^2)$를 가졌다. 각 황 함유 화학물의 분자구조와 PFPD의 황 함유 화합물 분석 원칙에 영향을 받는 것으로 사료된다. 서로 다른 세 종류의 fiber를 사용시, 미세 고체상 추출법(SPME)을 사용했을 때, CAR/PDMS fiber는 가장 좋은 추출 효율을 보였고, 반대로 PDMS/DVB fiber는 가장 낮은 효율을 나타내었다. SPME 방법을 사용하면, 시료에 포함되어 있는 6개의 황 함유 화합물들 중, 최대 5개까지 분석이 가능하였다. 그러나 본 실험에서 사용하지 않은 황 함유 화합물들도 다수 동정 되었는데, 이렇게 추출과정 중 artifacts로 생성된 황 함유 화합물들은 분석 시 오차를 작용할 수 있다. 고정상 기체추출법(SH)은 SPME와 비교했을 때 더 적은 수의 황 함유 화합물을 감지해냈다. SPME와 비교 시 SH의 추출 효율은 낮았지만, artifact로 생성되는 화합물의 수는 적었다.

사료내 다양한 첨가제가 넙치 (Paralichthys olivaceus) 치어의 성장 및 비특이적 면역반응에 미치는 영향 (Effects of Dietary Inclusion of Various Additives on Growth Performance and Immune Responses in Juvenile Olive Flounder(Paralichthys olivaceus))

  • 김강웅;김경덕;이봉주;이진혁;배승철;최윤희;한현섭
    • 수산해양교육연구
    • /
    • 제25권6호
    • /
    • pp.1285-1293
    • /
    • 2013
  • This study was conducted to investigate the effects of dietary inclusion of various additives Solid sulfur, fucoidan, and glucan on growth performance and immune responses in Juvenile olive flounder paralichthys olivaceus. Six experimental diets supplemented with : no additives (CON); 0.5 and 1.0% solid sulfur (S); 0.2 and 0.4% fucoidan (F); 0.1% glucan (G) of these additives diet on a dry-matter basis. Fish averaging $8.2{\pm}0.17g$ were fed one of six experimental diets in triplicate groups for 6 weeks. By the end of the feeding trial, weight gain, feed efficiency, specific growth rate, protein efficiency ratio, hepatosomatic index and condition factor of fish fed diet CON were significantly lower then those of fish fed the all additives diets (P < 0.05). In challenge test, fish were infected by intraperitonel injection of 0.1 ml bacterial suspension with Edwardsiella tarda per fish after the feeding trial. As a result fish fed All additive diet showed a lower cumulative mortality then did fish fed CON diet throughout the challenge test. In conclusion, these results indicated that solid sulfur, fucoidan and glucan enhanced the growth, feed efficiency and non-specific immune activity of juvenile flounder and protect the fish against microbial infections.

고체산화물 연료전지의 운전 조건에 따른 니켈 전극 황 피독 현상 (Sulfur Poisoning of Ni Anode as a Function of Operating Conditions in Solid Oxide Fuel Cells)

  • 이호성;이현미;임형태
    • 대한금속재료학회지
    • /
    • 제56권12호
    • /
    • pp.893-899
    • /
    • 2018
  • In the present study, we investigated the sulfur poisoning of the Ni anode in solid oxide fuel cells (SOFCs) as a function of operating conditions. Anode supported cells were fabricated, and sulfur poising tests were conducted as a function of current density, $H_2S$ concentration and humidity in the anode gas. The voltage drop was significant under the higher current density (${\sim}714mA/cm^2$) condition, while it was much reduced under the lower current density (${\sim}389mA/cm^2$) condition, at 100 ppm of $H_2S$. A secondary voltage drop, which occurred only at the high current density, was attributed to Ni oxidation in the anode. Thus, operation at high current density with high $H_2S$ concentration may lead to permanent deterioration in the anode. The effect of water content (10%) on the sulfur poisoning was also investigated through a constant current test (${\sim}500mA/cm^2$) at 10 ppm of $H_2S$. The cell operating with 10% wet anode gas showed a much smaller initial voltage drop, in comparison with a dry anode gas. The present study indicates that operating conditions, such as gas humidity and current density, should be carefully taken into account, especially when fuel cells are operated with $H_2S$ containing fuel.

$WS_2$ 고체 윤활제의 합성 (Synthesis of $WS_2$ Solid Lubricant)

  • 신동우;윤대현;황영주;김성진;김인섭
    • Tribology and Lubricants
    • /
    • 제13권4호
    • /
    • pp.60-65
    • /
    • 1997
  • The tungsten disulfide $(WS_2)$ solid lubricant was synthesized by two different reaction processes, i.e., the reaction between $CS_2$ gas phase and solid $WO_3$powder, and the vapour phase transport method of tungsten and sulfur in a high vacuum. The chemical and physical characteristics of synthesized $WS_2$powder were analyzed in terms of the average particle size, morphology, crystalline phase etc. in comparison with those of commercial $WS_2$powder. The solid $WO_3$ powder with the average size of 0.2 ${\mu}{\textrm}{m}$ was reacted with $CS_2$gas flowed with$N_2$or 96%$N_2{\times}4%H_2$forming gas for 36 h and 24 h at 90$0^{\circ}C$ respectively. $WS_2$ crystalline phase was then formed through the intermediate phase of .$W_{20}O_{58}$ In the case of vapour phase transport method, the 3.5 wt% iodine was added as a vapour transport reagent into the composition of tungsten and sulfur powders maintaining a constant molar ratio of W:S=1:2.2. The mixture was then heat treated at 85$0^{\circ}C$ for 2 weeks in vacuum. The reaction product obtained showed the average size of 12 ${\mu}{\textrm}{m}$ and the hexagonal plate shape of typical solid lubricant with 2H-$WS_2$crystalline phase.

상온용 나트륨/유황전지의 방전 특성 (Discharge Properties of Sodium-sulfur Batteries at Room Temperature)

  • 김태범;안효준;허보영
    • 한국재료학회지
    • /
    • 제16권3호
    • /
    • pp.193-197
    • /
    • 2006
  • The sodium/sulfur(Na/S) battery has many advantages such as high theoretical specific energy(760Wh/kg), and low material cost based on the abundance of electrode material in the earth. It has been reported that the electrochemical properties of sodium/sulfur cell above $300^{\circ}C$, utilized a solid ceramic electrolyte and liquid sodium and sulfur electrodes. A lot of researches have been performed in this field. Recently, Na/S battery system was applied for electricity storage system for load-leveling. One of severe problems of sodium/sulfur battery was high operating temperature above $300^{\circ}C$, which could induce the explosion and corrosion by molten sodium, sulfur and polysulfides. In order to develop sodium battery operated at low temperature, sodium ion battery has been studied using carbon anode, and sodium oxides cathodes. However, the energy densities of the sodium ion batteries were much lower than high temperature sodium/sulfur cell. In this study, the sodium/sulfur battery with 1M $NaCF_3SO_3$ is tested at room temperature. The charge-discharge mechanism was discussed based on XRD, DSC, SEM and EDS results.