• 제목/요약/키워드: Solar system design

검색결과 902건 처리시간 0.025초

국내의 태양열발전 기술개발 동향 및 설계 (Design and Development Trends of Solar Thermal Power Generation in Korea)

  • 강용혁;김진수;김종규;이상남;유창균;윤환기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.658-661
    • /
    • 2007
  • KIER have been developing high-temperature solar technology, especially the solar thermal power generation system, since the early of 1990s. In 1994, the first research on high temperature solar technology started with PTC technology. At the moment the most advanced 10kW dish system is under demonstration for 10kW solar thermal power generation. Test results showed about 19.2% solar to electricity average efficiency. Another research activities of KIER is hybrid power generation. For hybridization, solar and LFG(landfill gas) are used. Another hybrid solar system is with solar chemical reaction. In this system, power unit is gas turbine, and the heat content of fuel(like natual gas) is upgraded by solar energy through chemical reaction. The latest project on solar thermal power generation is for 1 MW power tower system. This is the Korea-China Joint project.

  • PDF

주택용 PV 시스템의 발전성능에 대한 연구 (A Study on Generation Capacity of Residence PV System)

  • 김병만;이길송;신현우;양연원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.190-192
    • /
    • 2008
  • The government plans to deploy 100,000 photovoltaic system in residential houses by 2012. In this paper, I described how to design the Residence PV System and how to simulated which predict the efficiency of its electrical generation. AS comparing the simulated data and actual installed 3kW photovoltaic power generation system. I analyze the condition of the Residence PV system and suggest the best way to design in best condition.

  • PDF

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

LEED 인증 받은 학교건축사례에서 재생에너지 활용 연구 분석 - 태양광 및 태양열 에너지를 중심으로 - (A Study on the Applications of Renewable Energy in LEED (Leadership in Energy and Environmental Design) Certified School Projects - Focused on Solar and Thermal Energy -)

  • 윤혜경;우승현;최효식
    • 교육시설 논문지
    • /
    • 제20권2호
    • /
    • pp.25-32
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art solar energy system design cases among LEED(Leadership in Energy and Environmental Design) certified school projects and to explore the feasibilities for their applications in domestic school design. Investigating the sold wattages in some kinds of buildings, the wattages per an educational facility is the second-largest after that per an industrial facility. That shows that our attention should be actively directed to the utilization of New and Renewable Energy in school facilities. Therefore photovoltaics systems, lighting systems and solarthermal facilities of solar energy systems were analyzed in the LEED cases. Findings demonstrate that applications of solar energy systems in K-12 educational facilities have been executed more than those in higher educational facilities. However, K-12 educational facilities and higher educational facilities by private funds are not categorized as Green Buildings by Support for Making Green Buildings Act. That fact is needed to be amended. Besides that, design developments are needed for building integrated photovoltaics systems and solarthermal facilities in domestic educational facilities.

A Simulation on the Performance of Durability in a Polymer Solar Glazing Design

  • Cahyono, Sukmaji Indro;Eom, Han-Saem;Ryu, Nam-Jin;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.331-336
    • /
    • 2012
  • Nowaday the conventional solar collector material prices are rising up because of pricy metal material over the world. The solar collector is too expensive to recycle to save the earth. Advanced polymer research is founded a high thermal resistant polymer and also it has high sun energy transmission. It also has cheaper material and easy manufacturing process, compare with conventional solar collector material. This paper is focussing on glazing simulation of polymer solar collector against wind pressure. The modeling geometry of polymer solar glazing are purposed by single layer, double layer hollow, zig-zag and tower. A simulation by using the Finite Volume was conducted to get Factor of Safety (FoS). The purpose of this paper is to find the best polymer glazing design, which can be as reference for the solar collector company to build Polymer. Hope fully new model of polymer solar collector has cheap, light, high sun energy transmitter, easy to be made and strong against wind force characteristics.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

국내 기상 측정결과를 이용한 일사량 예측 방법 기초 연구 (A Basic Study to Predict Solar Insolation using Meteorological Observation Data in Korea)

  • 황보성;김하양;김정배
    • 융복합기술연구소 논문집
    • /
    • 제4권2호
    • /
    • pp.27-33
    • /
    • 2014
  • To well design the solar energy system using solar energy, the correlation to calculate solar irradiation is basically needed. So, this study was performed to reveal the relationships between the solar irradiation and four meteorological observation data(dry bulb temperature, relative humidity, sunshine duration, and cloud cover) which are different from previous other researches. And then, we finally proposed the first order non-linear correlation from the measured solar irradiation using four meteorological observation data with MINITAB. To show the deviation of the solar irradiation between measured and calculated, this study compared using the daily total solar irradiance and the maximum peak value. From those results, the calculation error was estimated about maximum 25.4% for the daily total solar irradiance. The error of the solar irradiation between measured and calculated was made from the curve fitting error. So, solar irradiation prediction correlation with higher accuracy can be obtained using 2nd or higher order terms with four meteorological observation data.

진동 저감을 위한 복합재료 태양전지판의 최적설계 (Optimal Design of a Composite Solar Panel for Vibration Suppression)

  • 김용하;김휘엽;박정선
    • 항공우주시스템공학회지
    • /
    • 제12권6호
    • /
    • pp.50-57
    • /
    • 2018
  • 본 논문에서는 고기동 위성의 진동 저감을 위해 지지대를 복합재료 태양전지판에 적용하였다. 또한 리츠 법을 이용하여 지지대를 포함한 복합재료 태양전지판의 동역학적 모델을 정의하였으며, 지지대가 포함되지 않은 복합재료 태양전지판과 비교하여 지지대의 진동 흡수 성능을 확인하였다. 제한된 질량 내에서 진동 흡수 성능을 최대화하기 위해 정의된 동역학적 모델을 이용하여 지지대를 포함한 복합재료 태양전지판의 설계변수에 대한 최적설계를 수행하였으며, 최적화된 전개 고정형 복합재료 태양전지판의 설계안을 도출하였다.

액체식 태양열난방계통에 관한 연구 (A Study on the liquid Type Solar Heating System)

  • 남평우
    • 대한설비공학회지:설비저널
    • /
    • 제8권4호
    • /
    • pp.221-236
    • /
    • 1979
  • The three years Performance of a liquid type solar heating system has been determined for a system which has been determined for a system which has been operating continuously since 1976 in Seoul with no serious maintenance. A flat plate collector is used to transform incident solar radiation into thermal energy. This energy is stored if the form of sensible energy and used as needed to supply the space heating loads. An electric auxiliary heaters are provided to supply energy for space heating load when the energy in the storage tank is depleted. The ratio of useful collected solar heat divided by the total solar radiation on the collector was obtained about 84 per cent. It is also obtained the relation between ratio of solar collector area to the heating area and the ratio of useful collected solar energy to the heating load for the useful design data. A comparison between the measured and simulated results with the solar space heating system is described. Hour by hour simulation is made on unsteady state basis using the system parameters and meteorological data at the experiment site. The result of comparison turned out satisfactory for the solar heating system, though the simulation was formed somewhat higher than by experimental.

  • PDF