• Title/Summary/Keyword: Solar radiation rate

Search Result 200, Processing Time 0.011 seconds

Numerical Analysis of Heat Transfer in Multichannel Volumetric Solar Receivers (다채널 체적식 태양열 흡수기에서 열전달 수치해석)

  • Lee, Hyun-Jin;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1383-1389
    • /
    • 2011
  • The current study focuses on the consistent analysis of heat transfer in multichannel volumetric solar receivers used for concentrating solar power. Changes in the properties of the absorbing material and channel dimensions are considered in an optical model based on the Monte Carlo ray-tracing method and in a one-dimensional heat transfer model that includes conduction, convection, and radiation. The optical model results show that most of the solar radiation energy is absorbed within a very small channel length of around 15 mm because of the large length-to-radius ratio. Classification of radiation losses reveals that at low absorptivity, increased reflection losses cause reduction of the receiver efficiency, notwithstanding the decrease in the emission loss. As the average temperature increases because of the large channel radius or small mass flow rate, both emission and reflection losses increase but the effect of emission losses prevails.

A Study on the Improvement of the Accuracy of Photovoltaic Facility Location Using the Geostatistical Analysis (공간통계기법을 이용한 태양광발전시설 입지 정확성 향상 방안)

  • Kim, Ho-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.2
    • /
    • pp.146-156
    • /
    • 2010
  • The objective of this study was to improve the accuracy of calculation and estimation of solar radiation and duration of sunshine, which are the most important variables of photovoltaic power generation in deciding the location of photovoltaic facilities efficiently. With increasing interest in new and renewable energies, research on solar energy is also being conducted actively, but there have not been many studies on the location of photovoltaic facilities. Thus, this study calculated solar duration and solar radiation based on geographical factors, which have the most significant effect on solar energy in GIS environment, and corrected the results of analysis using diffuse radiation. Moreover, we performed ordinary kriging, a spatial statistical analysis method, for estimating values for parts deviating from the spatial resolution of input data, and used variogram, which can determine the spatial interrelation and continuity of data, in order to estimate accurate values. In the course, we compared the values of variogram factors and estimates from applicable variogram models, and selected the model with the lowest error rate. This method is considered helpful to accurate decision making on the location of photovoltaic facilities.

The inference about the cause of death of Korean Fir in Mt. Halla through the analysis of spatial dying pattern - Proposing the possibility of excess soil moisture by climate changes - (한라산 구상나무 공간적 고사패턴 분석을 통한 고사원인 추정 - 기후변화에 따른 토양수분 과다 가능성 제안 -)

  • Ahn, Ung San;Kim, Dae Sin;Yun, Young Seok;Ko, Suk Hyung;Kim, Kwon Su;Cho, In Sook
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.1
    • /
    • pp.1-28
    • /
    • 2019
  • This study analyzed the density and mortality rate of Korean fir at 9 sites where individuals of Korean firs were marked into the live and dead trees with coordinates on orthorectified aerial images by digital photogrammetric system. As a result of the analysis, Korean fir in each site showed considerable heterogeneity in density and mortality rate depending on the location within site. This make it possible to assume that death of Korean fir can occur by specific factors that vary depending on the location. Based on the analyzed densities and mortality rates of Korea fir, we investigated the correlation between topographic factors such as altitude, terrain slope, drainage network, solar radiation, aspect and the death of Korean fir. The density of Korean fir increases with altitude, and the mortality rate also increases. A negative correlation is found between the terrain slope and the mortality rate, and the mortality rate is higher in the gentle slope where the drainage network is less developed. In addition, it is recognized that depending on the aspect, the mortality rate varies greatly, and the mean solar radiation is higher in live Korean fir-dominant area than in dead Korean fir-dominant area. Overall, the mortality rate of Korean fir in Mt. Halla area is relatively higher in areas with relatively low terrain slope and low solar radiation. Considering the results of previous studies that the terrain slope has a strong negative correlation with soil moisture and the relationship between solar radiation and evaporation, these results lead us to infer that excess soil moisture is the cause of Korean fir mortality. These inferences are supported by a series of climate change phenomena such as precipitation increase, evaporation decrease, and reduced sunshine duration in the Korean peninsula including Jeju Island, increase in mortality rate along with increased precipitation according to the elevation of Mt. Halla and the vegetation change in the mountain. It is expected that the spatial patterns in the density and mortality rate of Korean fir, which are controlled by topography such as altitude, slope, aspect, solar radiation, drainage network, can be used as spatial variables in future numerical modeling studies on the death or decline of Korean fir. In addition, the method of forest distribution survey using the orthorectified aerial images can be widely used as a numerical monitoring technique in long - term vegetation change research.

Solar District Heating System (지역난방용 태양열시스템)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yoon, Eung-Sang;Yoon, Suk-Man;Sin, U-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation (파사드 일체형 자연순환 태양열온수기 유동해석)

  • Baek, Nam-Choon;Lee, Wang-Je;Lim, Hee-Won;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

The Evaluation of Geotextiles by Ultraviolet(UV) Effect during the Landfill Construction (폐기물 매립지의 부직포 포설시 UV 영향에 대한 평가)

  • 고재학;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.206-215
    • /
    • 1998
  • Using of geosynthetics with linear materials(sand, gravel, clay soil) is rapidly increased in landfill. With geosynthetics, geotextiles often expose to solar radiation(Ultraviolet) on long terms during the installation. In this paper, the results will represent the strength retention rate and tensile retention rate of geotextiles between outdoor exposed and protected by 15cm thickness of soil. As a result of cumulating solar radiation in geotextiles was increased, the strength retentions rate of P.P(500g/$m^2$), P.P(700g/$m^2$) and P.P(1000g/$m^2$) were decreased and the lower weight of unit area of geotextiles, the faster decrease of strength retention rate. P.E.T(600g/$m^2$) was showed a distinctive trend that the strength retention rate increased. The tensile retention rate of tested geotextiles was decreased during the simulation. However, the strength and tensile retention rate of geotextiles covered by soil had changed insignificantly. Therefore, it can surmise that the soil covering will help geotextiles to be protected from UV effecting

  • PDF

Frozen Orbits Construction for a Lunar Solar Sail

  • Khattab, Elamira Hend;Radwan, Mohamed;Rahoma, Walid Ali
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • Frozen orbit is an attractive option for orbital design owing to its characteristics (its argument of pericenter and eccentricity are kept constant on an average). Solar sails are attractive solutions for massive and expensive missions. However, the solar radiation pressure effect represents an additional force on the solar sail that may greatly affect its orbital behavior in the long run. Thus, this force must be included as a perturbation force in the dynamical model for more accuracy. This study shows the calculations of initial conditions for a lunar solar sail frozen orbit. The disturbing function of the problem was developed to include the lunar gravitational field that is characterized by uneven mass distribution, third body perturbation, and the effect of solar radiation. An averaging technique was used to reduce the dynamical problem to a long period system. Lagrange planetary equations were utilized to formulate the rate of change of the argument of pericenter and eccentricity. Using the reduced system, frozen orbits for the Moon sail orbiter were constructed. The resulting frozen orbits are shown by two 3Dsurface (semi-major, eccentricity, inclination) figures. To simplify the analysis, we showed inclination-eccentricity contours for different values of semi-major axis, argument of pericenter, and values of sail lightness number.

Experimental Studies for Solar Drying System of Agricultural Products(I) - Solar drying characteristics for radish - (태양열 건조 시스템에 관한 실험적 연구(I) - 무우절편의 태양열 건조 특성 -)

  • Koh, Hak-Kyun;Kim, Yong-Hyeon;Song, Dae-Bin;Kim, Man-Soo
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.9-20
    • /
    • 1991
  • Experiments for drying radish were carried out to analyze the drying characteristics and quality evaluation between solar heated-air drying and natural air drying system. Solar heated-air drying system consists of a small fan, a solar air heater and a tunnel dryer. Simulation model for thermal environments of solar collector was developed to investigate the effect of solar radiation and airflow rate on thermal performance.

  • PDF

Pulmonary and Cutaneous Evaporative Water Losses in Sahiwal and Sahiwal × Holstein Cattle During Solar Exposure

  • Aggarwal, Anjuli;Upadhyay, R.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.318-323
    • /
    • 1997
  • In order to assess the effect of solar exposure on pulmonary functions and evaporative losses from skin and pulmonary surfaces, in six healthy Sahiwal (S) and six Sahiwal ${\times}$ Holstein ($S{\times}H$) cattle were exposed to direct sun during summer. Breed differences were observed during exposure. Increase in sweating rate was higher in crossbreds (222%) than in Sahiwal (125%). Pre-exposure (ambient temperature, $32.6{\pm}0.85^\circ}C$, solar radiation, $0.9cal\;cm^{-2}min^{-1}$) evaporative loss from skin accounted for about 90% of the losses and remaining losses were contributed by pulmonary surfaces in Sahiwal. The contribution of evaporation through skin increased to 92% (ambient temperature $39.4{\pm}0.68^\circ}C$, solar radiation, $1.35cal\;cm^{-2}min^{-1}$). In crossbreds 80% of the evaporative losses were through skin before exposure which increased to 87% after exposure to solar radiations. Rectal temperature increase was higher in crossbreds ($1.5^{\circ}C$) than in Sahiwal ($0.8^{\circ}C$). With the increase in pulmonary evaporative losses, respiratory frequency increased to 2 fold in Sahiwal and pulmonary ventilation increased 1.6 times the resting value in Sahiwal due to solar exposure. In $S{\times}H$ crossbreds the respiratory frequency increased 3.5 times and pulmonary ventilation increased only to 1.8 times due to decrease in tidal volume. There was about 2 fold increase in alveolar ventilation in both the breeds, the increase in dead space ventilation was more in crossbreds than in Sahiwal. Behavioral symptoms exhibited by animals after exposure were profuse salivation, open mouth panting, tongue protrusion and general restlessness.

Performance Analysis of R-134a Rankine Cycle to Apply for a Solar Power Generation System Using Solar Collector Modeling (태양열 집열기 모델링을 활용한 발전용 R134a 랭킨사이클의 성능해석)

  • Joung, Jinhwan;Kang, Byun;Tong, Yijie;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.57-65
    • /
    • 2014
  • As the environmental regulations is more strengthened, the study of the renewable energy system and waste heat for electricity production is being accelerated. In this study, the performance and power generation rate of solar power generation by using R134a Rankine cycle was analyzed with solar radiation and mass flow rate of R134a. As a result, the maximum and minimum collected heat of solar collector was 20.4 kW and 13.6 kW at October and December, respectively. Besides, the highest generator power was generated at October and it was 0.91 kW/day, while the lowest generator power is occurred at December and it was about 0.85 kW/day.