• Title/Summary/Keyword: Soil boring

Search Result 96, Processing Time 0.027 seconds

Investigation and Analysis of Ground Deformation at a Coal Waste Depot in Dogye (도계 석탄폐석 적치장 주변지반의 지형변화 조사 및 분석)

  • Cho, Yong-Chan;Song, Young-Suk;Kim, Kyeong-Su
    • The Journal of Engineering Geology
    • /
    • v.21 no.3
    • /
    • pp.199-212
    • /
    • 2011
  • To investigate the causes of ground deformation around the Dogye coal waste depot in Samcheok city, Gangwon Province, we undertook a field survey and performed boring tests and a topographic analysis using maps compiled in various years. The results of boring tests and analyses of ground fractures indicate that the thickness of the soil layer ranges from 9 to 28.5 m and that ground deformation has occurred to the $240{\sim}250^{\circ}$ direction. The topographic analysis revealed that the topography of the site has changed continuously due to the dumping of coal waste. The causes of ground deformation, investigated by both field surveys and the topographic analysis, were the thick layer of soil at this site, the loading weight of coal waste, and the excavation at the lower part of the slope.

A Case Study on the Design of High Capacity Foundations for High-Rise Buildings (국외 초고층 건축물의 대형기초 적용 사례)

  • Cho, Sung-Han;Han, Byoung-Kwon;Lee, Je-Man;Kim, Tae-Bum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.78-89
    • /
    • 2007
  • Two design examples of deep foundations for high-rise buildings on soft ground are introduced in this paper. The first one is a 54-story building in Ho-Chi-Minh city, Vietnam, which was designed to be founded on $2.8m{\times}1.0m$ barrette foundations with approximately 60m to 75m depth. Based on a number of design guides and existing load test data from the construction sites in Ho-Chi-Minh city, the capacity of a barrette foundation in sand or clay layered ground was calculated to be 17.2MN to 27.8MN depending on the installing depth. The second one is a 40-story building in Baku city, Azerbaijan, which was designed to be supported by 2.0m diameter bored pile foundations with approximately 23m depth. As analytical or empirical guides for the local ground conditions were very limited, the design procedure from the SNiP Code, one of Russian specifications, was adopted and used to calculate the pile capacity. The capacity of bored pile foundation in highly weathered soil was expected to be 14.8MN to 15.5MN depending on the boring depth.

  • PDF

Evaluation of applicability of xanthan gum as eco-friendly additive for EPB shield TBM soil conditioning (친환경 첨가제로서 잔탄검의 토압식 쉴드 TBM 쏘일 컨디셔닝 적용성 평가)

  • Suhyeong Lee;Hangseok Choi;Kibeom Kwon;Byeonghyun Hwang
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.3
    • /
    • pp.209-222
    • /
    • 2024
  • The Earth Pressure Balance (EPB) shield Tunnel Boring Machine (TBM) is widely used for underground tunnel construction for its advantages, such as eliminating the need for additional facilities compared to the slurry shield TBM, which requires Slurry Treatment Plant (STP). During EPB shield TBM excavation, a soil conditioning technique is employed to enhance the physical properties of the excavated soil by injecting additives, thus broadening the range of applicable ground conditions to EPB shield TBMs. This study explored the use of xanthan gum, a type of biopolymer, as an alternative to the commonly used polymer additive. Biopolymers, derived from biological sources, are fully biodegradable. In contrast to traditional polymers such as polyacrylic acid, which contain environmentally harmful components, xanthan gum is gaining attention as an eco-friendly material due to its minimal toxicity and environmental impact. Test conditions with similar workability were established through slump tests, and the rheological characteristics were assessed using a laboratory pressurized vane shear test apparatus. The experiments demonstrated that, despite exhibiting similar workability, the peak strength in the flow curve decreased with increasing the content of xanthan gum. Consequently, a correlation between the xanthan gum content and peak strength was established. Replacing the traditional polymers with xanthan gum could enable stable EPB shield TBM operation by reducing equipment load, in addition to offering environmental benefits.

A Case Study on Design and Consruction for Cut Slope in Pa-ju Local Industrial Complex (파주 지방산업단지 대절토사면 설계 및 시공사례)

  • Lee, Jong-Ku;Kwon, Min-Seok;Paik, Young-Shik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.210-220
    • /
    • 2005
  • We have analyzed the stability for cut-slopes at main street 3-2 line section in Pa-ju local industrial complex. After studying an additional boring test, laboratory test and face mapping etc., we have determined the extent of reinforcement, slope inclinations and soil strength parameter from the analysis of test results. After changing the inclination of slopes for ground limit and carrying out the analysis of slope stability, we applied the Mass Nailing Method to the site because of need for reinforcement to soil and weathered rock slopes. In slope for soft and hard rock sections, we also reinforced the sections that are difficult to obtain the safety without reinforcement in alteration zone.

  • PDF

A study on the Heat Transfer Performance according to Ground Heat Exchanger Types (지중열교환기의 종류에 따른 열전달 성능에 관한 연구)

  • Hwang, SuckHo;Song, Doosam
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.75-80
    • /
    • 2010
  • Generally, ground-source heat pump (GSHP) systems have a higher performance than conventional air-source systems. However, the major fault of GSHP systems is their expensive boring costs. Therefore, it is important issue that to reduce initial cost and ensure stability of system through accurate prediction of the heat extraction and injection rates of the ground heat exchanger. Conventional analysis methods employed by line source theory are used to predict heat transfer rate between ground heat exchanger and soil. Shape of ground heat exchanger was simplified by equivalent diameter model, but these methods do not accurately reflect the heat transfer characteristics according to the heat exchanger geometry. In this study, a numerical model that combines a user subroutine module that calculates circulation water conditions in the ground heat exchanger and FEFLOW program which can simulate heat/moisture transfer in the soil, is developed. Heat transfer performance was evaluated for 3 different types ground heat exchanger(U-tube, Double U-tube, Coaxial).

An Analytical Study of Slope Stability to Reinforcement Stage in Cut Slope (절개사면에서의 보강단계별 사면안정성에 대한 해석적 연구)

  • Kang, Ki-Chun;Song, Young-Suk;Hong, Won-Pyo;Kim, Tae-Hyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.724-731
    • /
    • 2006
  • The purpose of this study is to estimate a landslide using the SLOPILE program from the slope reinforced by slope stability systems such as soil nailing and pile. To do this, cutting slope located at Donghae-Highway in Kwangwon-Do was considered. The behavior of slope was monitored for a long term by using instrumentation according to the reinforcement stages. The sequence of reinforcement stages was followed as pile installation, boring, soil nailing installation, anchoring and embankment. The result from this case study shows that the safety factor of slope depends on the reinforcement stage more or less.

  • PDF

Geotechnical Characteristics of Soft Clayey Soil in South Korea (국내 연약 점성토 지반의 지반공학적 특성)

  • Oh, Seo-Hyun;Ha, Tae-Gyun;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.922-929
    • /
    • 2009
  • In this paper, 4 representative soft clayey soils in south Korea are selected to estimate the geotechnical characteristics and provide the instructions avaliable for construction works; Inchon Coast, Kum River Estuary, Kwangyang Bay, and Nakdong River Estuary. Total 2250 boring data are collected to construct the data base system on selected areas from Korea geotech DB system, scientific journals, theses, and site investigation reports. Considering the geological, topographical and regional features, geotechnical properties, deformation and strength characteristics of 4 soft clayey soils are evaluated by analyzing the constructed DB system statistically.

  • PDF

Reliability Analysis of Geotechnical Properties in Incheon Port Area (인천항 지역의 지반정수 신뢰성 분석)

  • Shin, Eun-Chul;Jeon, Jae-Ku;Kim, Hyoung-Jun;Lee, Chung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.952-960
    • /
    • 2009
  • Foundation soils are greatly influenced on the stability of structures. The soft clay deposited in Incheon Port area is named either nomally consolidated clay or unconsolidated clay. New harbor structures will be constructed in Incheon Port area. Not sufficient soil boring datum are obtained from the filed soil exploration due to limited time and cost. The harbor construct site is pretty large area and the soils are not homogenous. This paper presented the result of reliability analysis which was performed by both Bayesian approach and analysis of variance.

  • PDF

표준관입시험 수행 과정에서의 문제점과 개선방향

  • 백세환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.275-280
    • /
    • 2001
  • Although important developments have taken place since ESOPT 1974 both with respect to the test method as well as the interpretation of the results, many uncertainties still remain in the Standard Penetration Test(SPT). The main pitfall of SPT is that it has not been standardized differing from its terminology and further, the possibility of standardization is very low in practice. Therefore, lack of knowledge on the equipment and method of SPT tends to cause some errors in interpretation of the results. It Is especially important to understand this tendency in domestic design, because most foundations are designed based on SPT results only. Many researchers have made an effort to minimize the uncertainties of SPf in Korea, it is not cleary defined what the most effective method of execution and interpretation of SPT Some uncertainties which many geotechnical engineers encounter in practice are introduced to discuss about improvement of test procedure and interpretation.

  • PDF

Site Investigations for Design Parameter Determination (설계정수 산정을 위한 지반조사)

  • Cho, Wan-Jei
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.785-789
    • /
    • 2009
  • It is essential to carry out appropriate site investigations for the accurate prediction of the geo-structure. However, the importance of the site investigation is often overlooked due to the time and expense constraints. In this study, several cases of geotechnical design perfromed in United States are introduced with the lessons about how the site investigations are planned, performed and applied for the actual design parameter determination. Based on the case studies presented herein, experienced geotechnical engineer should participate in site investigations from the planning stage through the final boring logs and utilize all the laboratory and field tests to have consistent input parameters for the soil constitutive models. Furthermore, it is also desired to have close relationship between construction industry and the academia to compensate their needs.

  • PDF