• Title/Summary/Keyword: Software Reliability Measurement

Search Result 155, Processing Time 0.026 seconds

Development of a Measurement Model of Personal Information Competency in Information Environment (정보 환경하에서 개인정보역량 측정모형 개발에 관한 연구)

  • Yoon, Chui-Young
    • The KIPS Transactions:PartD
    • /
    • v.14D no.1 s.111
    • /
    • pp.131-138
    • /
    • 2007
  • This study developed an efficient model for measuring personal information competency in an enterprise of the information environment. This model includes four measurement domains, twelve factors and feasible measurement items. This verified the validity and reliability of the developed model by factor analysis and reliability analysis through a pilot test with the application of SPSS software, and presented the concrete measurement items that tn efficiently gauge personal information competency. The developed model was applied to the measurement of 264 workers in an enterprise in order to testify its practicability and utilization, and the measurement results were presented. This model will contribute to improving the information competency of human resources in industrial fields.

A Study on the Validity and Test-Retest Reliability of the Measurement of the Craniovertebral Angle of the Smart Phone Application 'Angles Video Goniometer'

  • Hyeon-Seong Joo;Byeong-Soo Kim;Myung-Mo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.454-463
    • /
    • 2022
  • Objective: The purpose of this study was to compare concurrent validity and test-retest reliability based on Craniovertebral angle of 'Angles video goniometer', a smart phone application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity. This was conducted to find out whether 'Angle video goniometer' can be used clinically. Design: Cross-sectional study Methods: Fifty subjects were imaged laterally, and the angle of the head and spine was measured using Image J and the Angles video goniometer, respectively, in a resting posture and a chin in posture. The level of concurrent validity between the two measurement methods and the level of inter-rater reliability and intra-rater reliability were analyzed. Results: For forty participants, the concurrent validity between Image J and Angles video goniometer showed very high validity with ICC of 0.997(0.995~0.999) and 0.994(0.994~0.998), CVME% 0.71~0.72%, SEM% 0.31~0.34, MDC% 0.86~0.94. The test-retest intra-rater reliability showed very high reliability ICC 0.994(0.991~0.996), CVME% 0.71%, SEM% 0.31~0.43, MDC% 0.86~1.19%. The test-retest inter-rater showed very high reliability ICC 0.995(0.992~0.997), CVME% 0.71%, SEM% 0.43~0.59%, MDC% 1.20~1.62% Conclusions: Angles video goniometer', a smartphone application, is a device with very high reliability and validity for craniovertebral angle measurement in healthy adults, and it is a device that can be easily used in clinical practice.

A Study on the Validity and Test-retest Reliability of the Measurement of the Head Tilt Angle of the Smart Phone Application 'KPIMT Torticollis Protractor'

  • Seong Hyeok Song;Ji Su Park;Ki Yeon Song;Ki Hyun Baek;Seung Hak Yoo;Ju Sang Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2023
  • Purpose: The purpose of this study was to compare the concurrent validity and test-retest reliability of 'KPIMT Torticollis Protractor', a smart phone and I-pad application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity, according to head tilt and active cervical rotation angle. This was done to determine the clinical utility of 'KPIMT Torticollis Protractor'. Methods: Head tilt and active cervical spine rotation angles of 40 children with congenital muscular torticollis were measured using Image J and KPIMT Torticollis Protractor, respectively. The level of concurrent validity and inter-rater and intra-rater reliability between the two measurement methods were analyzed. Results: For forty participants, the concurrent validity between Image J and KPIMT Torticollis Protractor showed very high validity with ICC of ICC 0.977 (0.995-0.999), 0.994 (0.994-0.998), CVME% 0.71-0.72%, SEM% 0.31-0.34%, MDC% 0.86-0.94%. The test-retest intra-rater reliability showed very high reliability ICC 0.911 (0.911-0.966), CVME% 0.71%, SEM% 0.34-0.36%, MDC% 0.81-0.94%. The test-retest inter-rater showed very high reliability ICC 0.936 (0.933-0.957), CVME% 0.70%, SEM% 0.34-0.35%, MDC% 0.81-0.83%. Conclusion: The KPIMT Torticollis Protractor, a smart phone and IPD application, is a highly reliable and valid device for angle measurement in children with congenital myotonia and can be easily used in clinical practice.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

A Study on the Optimum Release Model of a Developed Software with Weibull Testing Efforts (웨이블 시험노력을 이용한 개발 소프트웨어의 최적발행 모델에 관한 연구)

  • Choe, Gyu-Sik;Jang, Yun-Seung
    • The KIPS Transactions:PartD
    • /
    • v.8D no.6
    • /
    • pp.835-842
    • /
    • 2001
  • We propose a software-reliability growth model incoporating the amount of testing effort expended during the software testing phase. The time-dependent behavior of testing effort expenditures is described by a Weibull curve. Assuming that the error detection rate to the amount of testing effort spent during the testing phase is proportional to the current error content, a software-reliability growth model is formulated by a nonhomogeneous Poisson process. Using this model the method of data analysis for software reliability measurement is developed. After defining a software reliability, we discuss the relations between testing time and reliability and between duration following failure fixing and reliability are studied in this paper. The release time making the testing cost to be minimum is determined through studying the cost for each condition. Also, the release time is determined depending on the conditions of the specified reliability. The optimum release time is determined by simultaneously studying optimum release time issue that determines both the cost related time and the specified reliability related time.

  • PDF

A case study of 6sigma application for the reliability in SPI based on SPICE (SPI 신뢰성 확보를 위한 SPICE 기반 6시그마 적용 사례 연구)

  • Kim Jong-Ki;Seo Jang-Hoon;Park Myeong-Kyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.4
    • /
    • pp.141-163
    • /
    • 2005
  • The international SPICE (Software Process Improvement and Capability determination) Project ISO/IEC 15504(SPICE : Software Process Improvement and Capability determination) is an emerging International Standard on SPA(Software Process Assessment). A prime motivation for developing this standard has been the perceived need for an internationally recognized software process assessment framework that pulls together the existing public and proprietary models and methods. A SPICE assessment can be considered as one of representative SPA model since assessors assign ratings to indicators and metrics to measure the capability of software process. But this models doesn't provide a systematic measurement procedures and dynamic method for SPI(Software Process Improvement). Through the evaluation of SPICE is capable of providing a substantiated basis for using the notion of capability, as well as providing information for nacessary improvements to the standard using 6sigma process. As a result, this paper propose a measurement procedure and guidelines for application of 6sigma process to guarantee the reliability in SPI and suggest the structure to support SPI on overall organization.

Performance estimation for Software Reliability Growth Model that Use Plot of Failure Data (고장 데이터의 플롯을 이용한 소프트웨어 신뢰도 성장 모델의 성능평가)

  • Jung, Hye-Jung;Yang, Hae-Sool;Park, In-Soo
    • The KIPS Transactions:PartD
    • /
    • v.10D no.5
    • /
    • pp.829-836
    • /
    • 2003
  • Software Reliability Growth Model that have been studied variously. But measurement of correct parameter of this model is not easy. Specially, estimation of correct model about failure data must be establish and estimation of parameter can consist exactly. To get correct testing, we calculate the normal score and describe the normal probability plot. Use the normal probability plot, we estimate the distribution for failure data. In this paper, we estimate the software reliability growth model for through the normal probability plot. In this research, we applies software reliability growth model through distribution characteristics of failure data. If we see plot, we determine the software reliability growth model, we can make sure superior in model's performance estimation.

Reasonability of Logistic Curve on S/W (로지스틱 곡선을 이용한 타당성)

  • Kim, Sun-Il;Che, Gyu-Shik;Jo, In-June
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • The Logistic cone is studied as a most desirable for the software testing effort. Assuming that the error detection rate to the amount of testing effort spent during the testing phase is proportional to the current error content, a software-reliability growth model is formulated by a nonhomogeneous Poisson process. Using this model the method of data analysis for software reliability measurement is developed. After defining a software reliability, This paper discusses the relations between testing time and reliability and between duration following failure fixing and reliability are studied SRGM in several literatures has used the exponential curve, Railleigh curve or Weibull cure as an amount of testing effort during software testing phase. However, it might not be appropriate to represent the consumption curve for testing effort by one of already proposed curves in some software development environments. Therefore, this paper shows that a logistic testing- effort function can be adequately expressed as a software development/testing effort curve and that it gives a good predictive capability based on real failure data.

A Study on Temperature Characteristics of Electric Apparatuses for High Speed Train (고속철도차량용 전기장치의 온도특성에 관한 연구)

  • 한영재;양도철;장호성;최종선;김정수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1210-1216
    • /
    • 2003
  • Recently, as the road capacity reaches the limit and environmental problems becomes serious, there is gradually increased a need for railroad vehicles that are environment-friendly and have time regularity, reliability, and safety. Accordingly, in addition to conventional railroad vehicles, lots of vehicles are being newly developed. We developed the hardware and software of the measurement system for on-line test and evaluation of korean high speed train. The software controls the hardware of the measurement system and acts as interface between users and the system hardware. In this paper, practical experiment are performed to verify mechanical performance of motor and main transformer for Korean high speed rail. The experimental test carried out by using new temperature measurement method and verify the temperature performance of motor and transformer is verified.

Modeling for Measurement of Class Reusability in Object-Oriented Programs (객체 지향 프로그램에서 클래스 재사용성 측정 모델링)

  • Yun, Hui-Hwan;Gu, Yeon-Seol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.3
    • /
    • pp.580-588
    • /
    • 1999
  • The reuse of software components from existing software system enhances productivity and reliability, decreases the cost of production in software development. The extraction of software components with high reusability from existing software system is very important in software reuse. The reuse of a class is classified into white-box reuse to reuse with modification and black-box reuse to reuse without modification. A class has the property of procedural language and object-oriented language. Therefore, it must measure reusability in consideration of two properties. In black-box reuse, independence of class is important quality. It can quantify through information hiding, coupling between objects, cohesion, etc. In white-box reuse, modification is the best important quality. It can quality through class complexity, coupling, cohesion, documentation, etc. We propose a new model for measurement of class reusability and the measure criteria in object-oriented program. A class that is measured by proposed model can judge whether the reuse with modification has the advantage or the reuse without modification has the advantage.

  • PDF