Development of Boost Chopper with Built New Renewable Energy in Grid-Connected Distributed Power System (승압 초퍼 기능이 내장된 새로운 태양광 발전용 파워컨디셔너의 개발)

  • Mun, Sang-Pil;Lee, Su-Haeng;Kim, Young-Mun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.361-367
    • /
    • 2014
  • This paper is related to a new solar power conditioner for a built-in step-up chopper function. In the first step-up chopper proposed solar PV power conditioner for mutually connected in series with the input voltage of the bypass diodes are respectively connected to the positive terminal should install the mutual boosting chopper diode connected in series with the boost chopper switching element between the two power supply and at the same time the first and the second was connected to a second diode and a resonance inductor and a snubber capacitor in series with each other. And the common connection point between the bypass diode and the step-up chopper and the step-up chopper diode common connection point of the switching elements of the input voltage was set to the boost inductor for storing energy. In addition, between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point of the first auxiliary diode and the second common connection point of the auxiliary diode was provided, the resonance capacitor. Between the step-up chopper and the step-up chopper diode and a switching element of a joint connection point and the common connection point of the resonance inductor snubber capacitor and connecting the third secondary diode, between two power supply lines is characterized by configuring the DC link capacitor bus lines in parallel. Therefore, it is possible to suppress the switching loss through, DC link bus lines, as well as there could seek miniaturization and weight reduction of the power conditioner itself by using a common capacitor of the non-polar non-polar electrolytic capacitor having a capacitor, the service life of the circuit can be extended and it is possible to greatly reduce the loss can be greatly improve the reliability of the product and the operation of the product itself.

Non-Isolation, High-Efficiency and High-Voltage-Output DC-DC Converter using the Self-Driven Synchronous Switch (자기구동 동기스위치를 이용한 비절연 고효율 고전압출력 DC-DC 컨버터)

  • Jeong, Gang-Youl
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.962-970
    • /
    • 2019
  • In this paper, the non-isolation, high-efficiency and high-voltage-output DC-DC converter using the self-driven synchronous switch is proposed. The proposed converter achieves high-voltage-output by applying a tapped inductor to the conventional boost DC-DC converter structure, and it reduces the voltage stress of main switch applying the lossless capacitor-diode (LCD) snubber to the switch. And the proposed converter applies the synchronous switch instead of the diode to the output part, and thus it resolves the reverse recovery problem and achieves high-efficiency. The synchronous switch of proposed converter uses the self-driven method and has a simple structure. In this paper, the operation principle of proposed converter is explained, and then, a design example of the converter prototype is presented. And the characteristics of the proposed converter are shown through experimental results of the prototype made with the designed circuit parameters.

An examples of a 6-inch GTO inverter drive system applied for rougher mills

  • Kawasaki, Muneo;Okayama, Hideo;Koyama, Masato;Mitsuhashi, Masamichi;Masuda, Hiroyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.25-28
    • /
    • 1996
  • Recently, AC variable-speed motors are used for many steel rolling mill drive systems, because of their low maintenance and enhanced control performance. We have been applied GTO inverters for these AC motor drive systems since 1993. We have developed world largest 6-inch diameter GTO and large capacity 3-level GTO inverter up to 20000(kVA). As an example, in this paper, we describe the main circuit, system arrangement and control features of the 6-inches GTO inverters to drive rougher mills for hot strip mill of Pohang Iron & Steel Co., Ltd. The motor capacity is 6000(kW), and it's overload is 250(%).

  • PDF

Application of Motor Drive System Using Resonant Voltage-Type Inverter (공진형 전압형 인버터의 전동기구동 시스템 응용)

  • Kim, Yong-Joo;Ma, Young-Ho;Kim, Han-Sung;Che, Geou-Ha;Kim, Byung-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.164-166
    • /
    • 1991
  • This paper achieved by Pulse-Withed Modulation of the inverter switchs. But Conventional PWM inverter is employed hard switching by means a switching device. Moreover, this paper presents resonant DC link Voltage type inverter thet it was not necessary snubber circuit and dead time and modeling of motor drive control system and simulating analysis are discussed.

  • PDF

Novel Soft Swithing Three - Phase High Power Factor converter (소프트 스위칭형 삼상 고역율 컨버터의 토포로지)

  • Kang, U.J.;Chung, S.H.;Kim, S.D.;Kwak, D.K.;Chun, J.H.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2221-2223
    • /
    • 1997
  • The proposed converter has a merit of simple controlled circuit because the input current control discontinuously. And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. Specially using the discontinuous current mode in the reactor. This topology is reduced a current /voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations of the proposed topology included in this paper.

  • PDF

A valve test system for series connected power semiconductor using resonant circuit (공진회로를 이용한 직렬연결 전력용 반도체 소자의 밸브 시험 시스템)

  • Yoo, H.H.;Han, Y.S.;Han, S.H.;Choi, J.Y.;Kim, J.M.;Kim, S.Y.;Yoon, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.203-205
    • /
    • 2006
  • 대용량 인버터의 기본 구성요소인 밸브를 시험하는 방식에 대해 제안하였다. 대용량 인버터를 구성하기 위해서는 전력용 반도체 소자를 직렬로 연결하여 고전압을 스위칭할 수 있는 밸브가 필요하다. 이 밸브의 Snubber 회로의 적정성, 정격전압, 정격전류에서 정상적으로 스위칭이 이루어지는지 등의 검증이 필요하다. 본 본문에서는 전력용 반도체 소자에 이러한 시험조건을 제공하는 시험방식을 제안하였다.

  • PDF

The design of on-board inverter using IGBT (IGBT를 이용한 탑재형 인버터 설계)

  • Kim, In-Soo;Kim, Seong-Shin;Lee, Kyung-Seok;Hwang, Yong-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1126-1128
    • /
    • 1992
  • The object of this study is the design of 3 phase on-board inverter. The key point in the inverter design is the selection of switching device, and its performance effects that of total system. In this study, six-step square wave inverter was designed using IGBT ( Insulated Gate Bipolar Transistor ) which has the advantages of MOSFET and bipolar transistor as switching device. The condition of being small and light which is the one of requirements for on-board equipment was accomplished by using IGBT module and optimising the snubber circuit, and the reliablity was increased. It is confirmed that the designed inverter satisfies the required performance through the performance and environment test.

  • PDF

High Step-Up Converter with Hybrid Structure Based on One Switch

  • Hwu, K.I.;Peng, T.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1566-1577
    • /
    • 2015
  • A novel high step-up converter is presented herein, which combines the conventional buck-boost converter, the charge pump capacitor and the coupling inductor. By doing so, a quite high voltage conversion ratio due to not only the turns ratio but also the duty cycle, so as to increase design feasibility. It is noted that the denominator of the voltage conversion ratio is the square of one minus duty cycle. Above all, there is no voltage spike across the switch due to the leakage inductance and hence no passive or active snubber is needed, and furthermore, the used switch is driven without isolation and hence the gate driving circuit is relatively simple, thereby upgrading the industrial application capability of this converter. In this paper, the basic operating principles and the associated mathematical deductions are firstly described in detail, and finally some experimental results are provided to demonstrate the effectiveness of the proposed high step-up converter.

Boost Converter with Low-Loss Snubber Circuit (저손실 스너버 회로를 적용한 승압형 컨버터)

  • Ryu M. H.;Baek J. W.;Kim J. H.;Yoo D. W.;Min B. D.;Rim G. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.700-703
    • /
    • 2004
  • 본 논문에서는 승압형 컨버터의 온/오프 스위칭 손실을 줄이기 위한 새로운 저손실 스너버 회로를 제안한다 제안하는 회로는 인덕터의 보조 권선을 통해 회로를 구성하며 부가되는 소자의 수가 작은 장점을 갖는다 제안하는 회로는 턴온 때에는 인덕터 보조 권선에 의해 스위치로 흐르는 전류의 상승을 제한하는 효과가 나타나므로 다이오드 역회복 전류에 의한 스위치 손실을 줄여준다. 동시에 턴오프시에는 스너버 회로를 통한 스위치 전압의 상승을 완만히 해주므로 역시 손실을 줄여준다. 본 논문에서는 1kW급의 단상 역률보상회로에 제안하는 회로를 구성하여 이의 동작을 검증하였다.

  • PDF

Power Conditioning Inverter Controlled by Sinewave Tracking Boost Chopper without DC Smoothing Capacitor Stage

  • Ahmed, Nabil A.;Miyatake, Masafumi;Kang, Tae-Kyung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.179-185
    • /
    • 2005
  • This paper presents a novel circuit topology of a high efficiency single-phase power conditioner. This power conditioner is composed of time-sharing sinewave absolute pulse width modulated boost chopper with a bypass diode in the first power processing stage and time-sharing sinewave pulse width modulated full-bridge inverter in the second power processing stage operated by time-sharing dual mode pulse pattern control scheme. The unique operating principle of the two power processing stage with time-sharing dual mode sinewave modulation scheme is described with a design example. This paper proposes also a sinewave tracking voltage controlled soft switching PWM boost chopper with a passive auxiliary edge-resonant snubber. The new conceptual operating principle of this novel power conditioner related to new energy utilization system is presented and discussed through the experimental results.