대심도 지하역사에서의 화재시 플랫폼 스크린 도어에 의한 열, 연기 거동 영향 분석 (The Analysis of the effects of the platform screen door on the fire driven flow in The Deeply Underground Subway Station)

  • 장용준;김학범;이창현;정우성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.1984-1989
    • /
    • 2008
  • In this study, fire simulations were performed to analyze the characteristics of the fire driven flow and the effects of the platform screen door on the smoke flow in the station, when the fire occurred in the center of the platform. Soongsil Univ. station (line number 7, 47m in depth underground) was chosen which was the one of the deepest underground subway stations in the Seoul metro, SMRT. The parallel computational method was employed to compute the heat and mass transfer eqn's with 6 CPUs of the linux clustering machine. The fire driven flow was simulated with using FDS code in which LES method was applied. The Heat release rate was 10MW and The Ultrafast model was applied for the growing model of the fire source. The 10,000,000 structured grids were used.

  • PDF

다중이용시설 바닥마감재의 연소가스 독성평가에 관한 실험 연구 (The Experimental Study on the Toxic Gases Released from the Floor Finishing Materials in Entertainment Service Industry Buildings)

  • 강성동;이창우;현성호;윤명오
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.14-21
    • /
    • 2002
  • 다중이용시설에서 많이 사용중인 바닥마감재를 대상으로 연소가스의 독성을 NES 713의 방법에 의해 평가하였다. 또한, 공기가 공급되지 않는 밀폐된 공간에서의 연소시 각 시료에 따라 발생할 수 있는 유독성가스를 가스분석기를 이용하여 시간변화에 따라 연속적으로 측정하여 비교·분석함으로서 화재 시 내포하고 있는 바닥마감재의 위험성을 평가하였다. NES 713 방법에 의한 각 제품의 유독가스의 독성지수를 살펴본 결과 2~9.7의 값을 갖고 있으며, 화재시 유독가스에 의한 매우 큰 위험성을 내포하고 있다.

수직 배연구의 자연배연 성능에 관한 수치해석연구 (A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-10
    • /
    • 2008
  • 본 연구에서는 미국 NFPA 204 기준에 의해 설계된 수직 배연구에 대하여 배연구의 위치, 외기 온도, 풍속 및 화재크기가 자연배연 성능에 미치는 영향과 화재특성을 CFAST 프로그램을 사용하여 수치 해석적으로 조사하였다. 배연구는 외벽의 최고 상부에 위치한 경우와 외기온도가 낮은 경우 및 풍속이 작은 경우 배연성능기준을 만족하였다. 또 화재크기가 클수록 배출량은 증가하나 연기층 높이는 낮아져 배연성능기준을 만족하지 못하였다. 직접 외기와 통하는 수직 자연배연구의 설계시 해당지역의 최고 온도와 최대 풍속을 고려하고, 설계화재를 정확히 결정하여 배연성능기준이 만족되도록 주의가 요망된다.

A Study on Fire Characteristics in a Tall and Narrow Atrium

  • Sugawa, Osami;Takahashi, Wataru;Ohtake, Masanori;Satoh, Hiroomi
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.353-360
    • /
    • 1997
  • The modeling on fire safety assessment for a tall and narrow atrium is carried out using a reduced and full scale atrium models based on the performances of flow behavior in and near comer fire and smoke ventilation system. The comer (or wall) effects on the flame behavior considering air entrainment into a flame was evaluated theoretically and experimentally. Temperature, upward velocity, inlet air velocity, and pressure difference between the atrium space and atmosphere were measured systematically in a reduced scale model. The performance of the modeling to estimate temperature rise and natural air ventilation volume was verified based on the experimental results. Smoke filling rate from a model fire source set at the center of a tall and narrow atrium is fastest in the other cases in which fire source set in or near a corner. This suggested that the centering of the fire source is acceptable as the fire source position to assess the fire safety design for a tall and narrow atrium.

  • PDF

가솔린 직접분사식 압축착화 엔진의 가능한 운전영역에 관한 기초실험 연구 (A Basic Experimental Study on Potential Operating Range in Gasoline Direct-Injection Compression Ignition (GDICI) Engine)

  • 차준표;윤성준;이석훤;박성욱
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.33-35
    • /
    • 2013
  • The present work is an experimental investigation on potential operating range using directly injected gasoline fuel in a single-cylinder compression ignition (CI) engine. The objectives of present study were to apply auto-ignited combustion to gasoline fuel and to evaluate potential operating range. In order to auto-ignite gasoline fuel in CI engine, the fuel direct-injection system and the intake air system were modified that a flow rate and temperature of intake air were regulated. The heat-release rate (HRR), net indicated mean effective pressure (IMEP), start of combustion (SOC), and combustion duration were derived from in-cylinder pressure data in a test engine, which has 373.33cc displacement volume and 17.8 compression ratio. The exhaust emission characteristics were obtained emission gas analyzer and smoke meter on the exhaust line system.

  • PDF

레인지후드 역류 저감 시스템 개발 (Range Hood Backflow Reduction Device Development)

  • 이원섭
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.906-911
    • /
    • 2018
  • This study was conducted to develop an efficient high performance range hood and exhaust system for quickly discharging flue gas, smoke, and odor generated when food is cooked in the kitchen, and the following results were obtained. Reverse current rate of 1.53 m/s of the range exhaust system was improved to achieve the inlet speed of 0.3 m/s or less. An efficient range system was constructed by improving the hood exhaust flow by 5.6 m/s at the existing 4.5 m/s.

가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구 (A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System)

  • 유우준;남준석;김동준;이정균;유홍선
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.53-58
    • /
    • 2012
  • 본 연구에서는 가연성 물질을 고려한 워터커튼 시스템(Water Curtain System)의 열 및 연기유동 제어 특성을 실험적으로 분석하였다. 이를 위해서 Room Corner Tester(RCT)를 사용하여 연료의 종류가 소나무(PineWood)와 가솔린(Gasoline)인 경우 각각의 발열량(Heat Release Rate)을 구하였으며, 워터커튼용 화재실험 장치를 제작하여 화원근방에서 5m 떨어진 지점의 천장 부근에 분사각도 $180^{\circ}$, 오리피스 직경 8.2 mm의 노즐(Nozzle)을 설치한 후 목재와 가솔린 각각에 대해서 화재실험을 실시하여 워터커튼 전후의 온도분포와 가시도를 측정하였다. 그결과 워터커튼 시스템의열및연기유동 제어는 가연성 물질의 연소특성에 따른 고온의 연기발생량과 분사 노즐에 의한 유동현상이 중요한 상관관계를 갖고 있음을 확인하였다.

저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구 (Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels)

  • 홍기배;나준영;유홍선
    • 한국산학기술학회논문지
    • /
    • 제20권4호
    • /
    • pp.619-625
    • /
    • 2019
  • 저심도 터널에서는 온도차에 의한 부력을 이용한 자연배기시스템이 많이 사용되고 있지만 이는 연기배출을 인위적으로 조절할 수 없다. 그러므로 자연배기시스템에서는 수직환기구에서 연기 배출량이 설계된 연기 배출량보다 적어지는 Plug-holing 현상을 고려한 설계가 필수적이다. Plug-holing 현상은 터널과 수직환기구의 형상 위치, 화원의 위치와 발열량 등에 영향을 받는다. 본 연구에서는 터널과 자연 환기구의 단면적 비와 화원의 열방출률이 자연배기시스템에서 발생하는 Plug-holing 현상에 미치는 영향에 대하여 실험적으로 분석하였다. 1/20 크기로 축소시킨 실험모델에서 터널과 수직환기구의 종횡비는 고정시키고 터널과 수직환기구의 단면적 비를 달리하여 Plug-holing 현상에 미치는 영향을 확인하였다. 화원의 열방출율은 0.55 kW, 0.98 kW, 1.67 kW로 고정시켰다. 실험결과, 연기 경계층온도와 수직환기구 내의 온도와의 비교를 통한 Plug-holing 발생을 판단하였고, 터널과 수직환기구의 단면적 비가 증가함에 따라서 수직환기구 하부의 유동과 온도분포 특성이 변함을 확인하였다. 터널 화재 시 Plug-holing 현상은 터널과 수직환기구의 단면적 비에 영향을 받으며 단면적 비가 클수록 Plug-holing 발생 가능성이 증가하였다.

삼각형 멀티 탭을 이용한 충돌제트 열전달 향상 연구 (Enhancement of Impinging Jet Heat Transfer Using Triangular Multi-Tabs)

  • 이정욱;이상준
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1139-1146
    • /
    • 2004
  • The effect of triangular tabs attached at the perimeter of jet nozzle on heat transfer enhancement was investigated experimentally. The modified flow structure was visualized using a smoke-wire method. Four different types of jet nozzle having 0, 4, 6 and 8 tabs were tested at jet Reynolds number Re=15,000 to investigate the effect of tabs on the variation of heat transfer rate. The local and average Nusselt numbers are increased with increasing the number of tabs. At nozzle-to-plate distance of L/D=4, the average Nusselt number was increased about 9.9% at Re=15,000 in the impingement region for the case of 8 tabs attachment. As the nozzle-to-plate distance increases, however, the heat transfer enhancement effect of triangular tabs is reduced. For the case of 4 tabs, the heat transfer enhancement is not so distinctive at L/D=8. As the protrusion depth of tabs into the jet flow increases, the heat transfer rate is also enhanced when the nozzle-to-plate distance is smaller than L/D=6.

공동주택 화재 시 화재크기 및 실내 개구부 크기가 화재풍속에 미치는 영향에 관한 수치해석적 연구 (Numerical Study on the Effect of Heat Release Rate and Interior Opening on Fire Flow Velocity in the Case of Interior Fire in an Apartment Building)

  • 서찬원;신원규
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.37-43
    • /
    • 2014
  • 재실자가 부속실로의 피난 시 부속실 송풍기가 작동하기 전단계에서는 실내화재로 인한 풍속이 발생하여 부속실 개방과 더불어 연소생성물이 부속실을 오염시켜 피난장애의 결과를 가져올 수 있다. 이로인한 화재크기 및 실내 개구부 크기가 화재풍속에 미치는 영향을 확인하기 수치해석 연구를 수행하였다. 수치해석에서는 화재크기 및 실내 개구부 크기를 달리하였고, 실제의 공동주택 형상과 치수를 반영하였다. 수치해석 결과, 화재크기별 실내의 개구부 크기에 따라서 중성대 높이가 변화하여 부속실로 흐르는 화재풍속 특성이 다르게 나타남을 확인할 후 있었다. 또한, 실내 중성대가 높은 곳에 형성된 경우에는 방화문 상 하부에서 화재풍속의 차이가 나타남을 확인할 수 있었다.