• Title/Summary/Keyword: Smart Metering

Search Result 107, Processing Time 0.023 seconds

Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway (도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Jongyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

Research Regard to Necessity of Smart Water Management Based on IoT Technology (IoT 기술을 활용한 스마트 물관리 필요성에 관한 연구)

  • Choi, Young Hwan;Kim, Yeong Real
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.4
    • /
    • pp.11-18
    • /
    • 2017
  • The Objective of this Study is to Prove the Effectiveness of a Smart Water Management(SWM) Technology. The SWM Technology can Reduce the Production Cost using Internet of Thing(IoT) Technology that Utilizes Remote Metering of Consumer's Water usage and Reduce the Leakage of Supply Facilities. The SWM Demonstration Model Installed a Remote Water Leakage Sensor, Smart Metering and Micro Multi Sensor in Water Supply Facility, and Provided Real-Time Monitoring of the Operation Status. Consumers can be Provided the usage of Tap Water and the Water Puality through a Smart Phone Application. At this Time, we Surveyed Whether Consumers save the Tap Water or Drinking Directly using the Tap Water usage Information. Also, this Study is to Verify the Degree of Improvement of Water Supply Rates and Drinking Water Rate, and to Decrease Consumer's Complaints, Operating Costs, and Water Consumption by the SWM Technology. It is also Established a SWM Model Combined with the IoT Sensor at Supply Facilities, operator monitoring system and explored recovery solution detected events. It means the upbringing of the domestic water industry by developing the related technologies and spreading the SWM to advanced levels.

Development of Low Voltage AMI(Advanced Metering Infrastructure) System using PLC (PLC를 이용한 저압 AMI(Advanced Metering Infrastructure) 시스템 구축)

  • Jung, Joon-Hong;Kim, Sung-Man;Jung, Su-Mi;Kim, Kwang-Young;Kim, Hong-San
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.743-744
    • /
    • 2011
  • Currently, the major issue in power system is construction of smart grid. Unlike conventional electricity grids, smart grid allows two-way communication between electricity suppliers and consumers, as well as enabling more dispersed generation and storage of power. The AMI(advanced metering infrastructure) system is the core technology of smart grid and this paper deals with the design methodology of AMI System using PLC(power line communication) networks.

  • PDF

A Wireless Network Structure and AKA(Authentication and Key Agreement) Protocol of Advanced Metering Infrastructure on the Smart Grid based on Binary CDMA (스마트 그리드를 위한 Binary CDMA 기반의 AMI 무선 네트워크 구조 및 AKA 프로토콜)

  • Jeon, Jae-Woo;Lim, Sun-Hee;Yi, Ok-Yeon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.5
    • /
    • pp.111-124
    • /
    • 2010
  • AMI (Advanced Metering Infrastructure) is a core infrastructure of Smart Grid, and is promoting in various country. Wireless network is considered for cost savings and operational efficiencies in AMI. But various security problems are expected in wireless networks of AMI, so we should solve these problems. In this paper, we suggest a wireless network of AMI by using Binary CDMA and security countermeasures of AMI wireless network. Proposed security architecture is using BSIM (Binary Subscriber Identity Module) to perform user authentication and key agreement for the encryption and decryption over radio network to reduce security threats.

A Study on Metering Data De-identification Method for Smart Grid Privacy Protection (스마트그리드 개인정보보호를 위한 미터링 데이터 비식별화 방안 연구)

  • Lee, Donghyeok;Park, Namje
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.6
    • /
    • pp.1593-1603
    • /
    • 2016
  • In the smart grid environment, there are various security threats. In particular, exposure of smart meter data can lead to serious privacy violation. In this paper, we propose a method for de-identification method of metering data. The proposed method is to de-identify the time data and the numeric data, respectively. Therefore, it can't analyze the pattern information from the metering data. In addition, there is an advantage that the query is available, such as the range of search in the database for statistical analysis.

Implement of a Watt-Hour Meter Monitoring System using Powerline Communication (전력선 통신을 이용한 전력량계 모니터링 시스템 구현)

  • Park, Keun-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1143-1148
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system with applying a Power Line Communication (PLC) modem and a Data Concentrator Unit (DCU). PLC modem uses the power line, so there is no need to install dedicated wiring. This system makes it possible to monitor the amount of electricity of previous current month metering data, so it can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.

A Development of Intelligent Metering and Control System for Energy Management of Electric Cabinet Panel (분전반 전력관리용 지능형 계측 제어 시스템 개발)

  • Park, Byung-Chul;Park, Jae-Sung;Song, Sung-Kun;Shin, Joong-Rin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.90-97
    • /
    • 2013
  • In recent years, the many electric saving methods are studied because of difficulty of meeting the demand. The electric energy management such as monitoring of branch power consumption, demand control, metering, power quality monitoring, electric safety monitoring can make energy saving. The purpose of this paper is to develop a system which can provide the integrated management of various functions required for energy management by consumers. In this system all functions which were embodied into each devices are integrated into intelligent meter. The developed systems are tested and implemented by installing at consumer electric distribution panel.

Analysis of Data Processing Efficiency using Duplicated Data Removal in AMI (AMI의 중복데이터 제거를 통한 데이터처리효율성 분석)

  • Oh, Do Hwan;Park, Jae Hyung
    • Smart Media Journal
    • /
    • v.10 no.2
    • /
    • pp.9-15
    • /
    • 2021
  • Due to widespread construction of AMI(Advanced Metering Infrastructure), various service tends to increase, which are not only remote metering service collection measuring data but also demand management and energy saving using measuring data. In order to support a stable management of such services, it is necessary for measuring data to be processed efficiently. In this paper, we analyze a performance of measured data processing efficiency using duplicated data removal according to AMI construction purpose on real environments.

The Integrated SCADA Data Gateway Platform based on SmartGrid (스마트 그리드 기반 통합 SCADA Data Gateway 플랫폼)

  • Song, Byung-Kwen
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.140-145
    • /
    • 2014
  • OPC UA(IEC62541) is a communication protocol for SG(Smart Grid) application platform. It was standardized by IEC TC57 group in December 2012. The IEC61850 has been used in Digital Substation Systems and Smart Distributed Systems. The DNP3.0 has been used for device's data collection/control in Distributed Systems. The DLMS/COSEM has been used to control metering and collect information in the Smart Metering. The top-level SG management platform needs an independent middleware to manage transparently the Power Information Technology, including the IEC61850, DNP3.0, DLMS/COSEM. In this paper, we propose the SDG(Scada Data Gateway) platform. It manages Power Information Technology based Digital Substation Systems and Smart Distributed systems, Smart Metering through OPC UA.