• Title/Summary/Keyword: Small-scale water supply

Search Result 71, Processing Time 0.026 seconds

Experimental Study on the Extinguishing Characteristics of Twin-fluid Nozzle using a Small-scale Hexane Pool Fire (소규모 헥산 풀화재를 이용한 2유체노즐의 소화 특성에 대한 실험적 연구)

  • Jeong, Chan Seok;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.35-41
    • /
    • 2018
  • Experiments were performed on 140 ml hexane pool fire extinguishment using a twin-fluid nozzle. For this pool fire, the area of the fire source (round shape of 80 mm in diameter) was $0.005027m^2$ and the measured heat release rate was 2.81 kW. The flow rates of water and gas (air and nitrogen) supplied to the twin-fluid nozzle were 156-483 g/min (~0.156-0.483 l/min) and 30-70 l/min, respectively. In the present experimental ranges, the high gas flow rate conditions led to the successful extinguishing of the pool fire. Under the low gas flow rate conditions in the extinguishment regime, the extinguishment time was long and the estimated water consumption was high. Under high gas flow rate conditions, however, the water flow rate conditions did not appear to have a great impact on the extinguishment time and estimated water consumption. On the other hand, in the present experimental ranges, the types of supply gas did not appear to affect the extinguishable flow rate condition, extinguishment time, and estimated water consumption. Finally, using the present experimental results with previous ones using a single-fluid nozzle, the water consumption of twin-fluid and single-fluid nozzles for extinguishing a 140 ml hexane pool fire were preliminarily compared and discussed.

Survey for Farmland Development in Western Coast of North Korea Using Satellite Image Data (인공위성 화상데이터를 이용한 북한 서해안지역의 농지기반조성 현황조사)

  • An, Gi Won;Jo, Byeong Jin;Seo, Du Cheon;Lee, Jeong Cheol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.1
    • /
    • pp.96-96
    • /
    • 2001
  • The aim of this study was to find out and confirm the project formulation, feasibility, scale and locations on the farmland development projects such as planned and ongoing tideland reclamation and irrigation facilities along the western coast of North Korea using satellite image data, Landsat TM, JERS OPS and SPOT PAN and aged maps. In order to apply to the study, remote sensing technologies such as geometric correction. digital mosaicking, image merging, linear extraction and land cover classification were studied. As the results of the study, the reclaimable tidal flats are recognized at about 178,000 ha equivalent to 59% of announced 300,000ha. and 16,000 ha of completed, 17,000 ha of ongoing project areas although 27,000 ha were revealed to be completed during 1987-1993. Almost planned projects are appeared to be shortage of water supply due to their small watersheds, however, most projects are connected with 2000 mile canal system.

Survey for Farmland Development in Western Coast of North Korea Using Satellite Image Data (인공위성 화상데이터를 이용한 북한 서해안지역의 농지기반조성 현황조사)

  • 안기원;조병진;서두천;이정철
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.1
    • /
    • pp.95-106
    • /
    • 2001
  • The aim of this study was to find out and confirm the project formulation, feasibility, scale and locations on the farmland development projects such as planned and ongoing tideland reclamation and irrigation facilities along the western coast of North Korea using satellite image data, Landsat TM, JERS OPS and SPOT PAN and aged maps. In order to apply to the study, remote sensing technologies such as geometric correction. digital mosaicking, image merging, linear extraction and land cover classification were studied. As the results of the study, the reclaimable tidal flats are recognized at about 178, 000 ha equivalent to 59% of announced 300, 000ha. and 16, 000 ha of completed, 17, 000 ha of ongoing project areas although 27, 000 ha were revealed to be completed during 1987-1993. Almost planned projects are appeared to be shortage of water supply due to their small watersheds, however, most projects are connected with 2000 mile canal system.

  • PDF

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

A Study on the Safety Code Development of Gas Engine Micro Combined Heat and Power System (소형 가스엔진 열병합 발전시스템 안전기준 개발)

  • Kwon, Jun-Yeop;Kim, Min-Woo;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2021
  • Recently, as a solution to the sharp drop in "power reserve ratio", it is being converted to a microgrid that enables bi-directional transmission and distribution. A microgrid is composed of a small-scale distributed power supply and a load. As a representative technology of distributed power generation, there is a Micro Combined Heat and Power system applied to homes and buildings. In this study, a safety standard was developed by dividing the power generation system, cooling system, lubrication system, and exhaust system to derive safety standards for a small gas engine power generation system with a gas consumption less than 232.6kW (200,000 kcal/h). In the case of the power generation system, a filter was installed and the system was stopped by detecting gas leakage and abnormalities in engine speed or output and the cooling system is stipulated to stop the system in case of insufficient cooling water or overheating. The lubrication system monitors the pressure and temperature of the lubricating oil and stops the system when an abnormality occurs, and the exhaust gas emission concentration regulation value was specified in accordance with domestic and foreign standards. Through the results of this study, it is judged that the safety of the gas engine power generation system can be improved and it can contribute to the commercialization of products.

Convergence of Remote Sensing and Digital Geospatial Information for Monitoring Unmeasured Reservoirs (미계측 저수지 수체 모니터링을 위한 원격탐사 및 디지털 공간정보 융합)

  • Hee-Jin Lee;Chanyang Sur;Jeongho Cho;Won-Ho Nam
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_4
    • /
    • pp.1135-1144
    • /
    • 2023
  • Many agricultural reservoirs in South Korea, constructed before 1970, have become aging facilities. The majority of small-scale reservoirs lack measurement systems to ascertain basic specifications and water levels, classifying them as unmeasured reservoirs. Furthermore, continuous sedimentation within the reservoirs and industrial development-induced water quality deterioration lead to reduced water supply capacity and changes in reservoir morphology. This study utilized Light Detection And Ranging (LiDAR) sensors, which provide elevation information and allow for the characterization of surface features, to construct high-resolution Digital Surface Model (DSM) and Digital Elevation Model (DEM) data of reservoir facilities. Additionally, bathymetric measurements based on multibeam echosounders were conducted to propose an updated approach for determining reservoir capacity. Drone-based LiDAR was employed to generate DSM and DEM data with a spatial resolution of 50 cm, enabling the display of elevations of hydraulic structures, such as embankments, spillways, and intake channels. Furthermore, using drone-based hyperspectral imagery, Normalized Difference Vegetation Index (NDVI) and Normalized Difference Water Index (NDWI) were calculated to detect water bodies and verify differences from existing reservoir boundaries. The constructed high-resolution DEM data were integrated with bathymetric measurements to create underwater contour maps, which were used to generate a Triangulated Irregular Network (TIN). The TIN was utilized to calculate the inundation area and volume of the reservoir, yielding results highly consistent with basic specifications. Considering areas that were not surveyed due to underwater vegetation, it is anticipated that this data will be valuable for future updates of reservoir capacity information.

The Business Model & Feasibility Analysis of the Han-Ok Residential Housing Block (한옥주거단지 사업모델구상 및 타당성 분석)

  • Choi, Sang-Hee;Song, Ki-Wook;Park, Sin-Won
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.453-461
    • /
    • 2011
  • This study is to derive a project model based on potential demand for Korean-style houses, focusing on new town detached housing sites that LH supplies and to test validity of the derived model and to present the direction and supply methods of the projects. The existing high-class new town Korean-style housing developments that have been considered were found to have little business value due to problems in choice of location and discordance of demand, so 6 types of projects were established through the methods of changes in planned scale, combined use, and subdivision of plot of land based on the results of survey. The type that has the highest business value among the project models was block-type multifamily houses, and this can be interpreted as the increase in total construction area leading to increase inrevenues of allotment sales due to economies of scale. The feasibility of mass housing model in which small-scale Korean-style houses are combined with amenities was found to be high, and if the same project conditions as those of the block-type multifamily houses are applied, the business value of the Korean-style tenement houses was found to be high. Besides, the high-class housing models within block-type detached housing areas are typical projects that the private sector generally promotes, and the construction cost was found to be most expensive with 910 million won per house. In order to enhance the business value of the Korean-style housing development, collectivization such as choice of location, diversification of demand classes, optimization of house sizes, and combination of uses is needed. And in order to adopt Korean-style houses in the detached housing sites, the adjustments and division of the existing planned plots are needed, and the strategies to cope with new demand through supplying Korean-style housing types of sites can be suggested. Also breaking away from the existing uniform residential development methods, the development method through supplying original land that is natural land not yet developed besides basic infrastructures (main roads and water and sewage) can be considered, and as the construction of more than 1~2 stories building is impossible due to the structure of Korean-style house roof and furniture. So it can be suggested that original land in the form of hilly land is considered to be most suitable to large-scale development projects.

PROPAGATION OF GRASS CARP AND SILVIR CARP, 1971 (초어 및 백련의 종묘 생산에 관한 연구, 1971)

  • KIM In-Bae;PAIk Eui In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.4 no.3_4
    • /
    • pp.113-120
    • /
    • 1971
  • In 1971, about 150,000 fingerlings of grass and silver carps were produced and distributed from the Fishculture Laboratory of Pusan fisheries College. The adults Were those transplanted from Japan in 1963. Findings during the process of this production are summarized as following : 1. Brood fish must be handled with a great care during the catching, hormone injection and maturity inspection so as the fish are not injured, otherwise, the eggs would not mature perfectly. Scale fall also affects significantly. 2. The amount of pituitary to be injected is preferable to be 2 to 3 times or more in donor's body weight to obtain good results. 3. The eggs should be spawned or stripped and inseminated as soon as mature. If the spawning is delayed the eggs become overmature and the hatching rate decreases significantly. 4. The water once used for the incubation of eggs should not be reused. The eggs under hatching process were melted away when water once used for incubation was reused. 5. A great care must be paid to keep water in quality when the net cage culture system is employed for raising fry or early fingerlings of Chinese carps. The best method to keep water in quality is to supply water in the cage continuously through a pipe or hose. 6. Heavy outbreaks of Spirogyra occured when clear well water was supplied into the cage, and a great number of fry or fingerlings were trapped or entangled resulting in a significant decrease of fish under rearing. It was prevented when moderately bloom-ed pond water was supplied into the cage. 7. Silver carp fry are usually captured and transported in the cool season because they can not be handled in the warm season owing to a high mortality, but cage cultured small size fingerlings ranging from 1.5 to 2 cm in total length are easily handled and transported even in the hot summer season, thus it enables the fish farmers to start growing them one season earlier.

  • PDF

The Error Analysis of Scale Effect for Dam Submerged Area and the Surrounded Regions (댐 수몰 및 주변지역의 축척 규모에 따른 오차분석)

  • Lee, Geun-Sang;Choi, Yun-Woong;Hwang, Eui-Ho;Chae, Young-Gang
    • Spatial Information Research
    • /
    • v.18 no.4
    • /
    • pp.43-53
    • /
    • 2010
  • A dam is effective in stable supply of water required in daily life and reduction of damage from floods. hut a lot of land or houses arc submerged due to the construction of a darn heavily affecting environment in surrounding areas. In order to improve and support daily life environment. surrounding a dam, many projects have been conducted. and the study has focused on analyzing bow to calculate error characteristics of scale effect for submerged area by using GIS spatial overlay. First, as a result of areal error in submerged area by scale based on a 1/3,000 digital topographic map, it was found that the 1/5,000 digital topographic map is 9.5 times, 9.0 times and 10.5 times more accurate than the 1/25,000 digital topographic map, respectively, in the total of areal error, standard error and areal error for submerged area. Second, as a result of analysis on areal error in areas surrounding a dam, it has been found that Jinan-eup in Jinan-gun registered the largest difference in area within 2km and 2~5km catchment area by recording 13.8 times and 20.6 times, respectively, in the 1/5,000 digital topographic map compared to the 1/25,000 digital topographic map. In addition, in areas out of catchment area within 2km, the area of occupation was very small, so there were no characteristics in error. The out of catchment area, Nami-myeon in Geumsan-gun recorded the largest errors of 31.8 times. Finally, it was found that the ratio of the total areal error in area surrounding a dam, standard error and the total areal error in the entire area using 1,5000 digital topographic map is 7.4 times, 11.8 times and 7.4 times more accurate than the 1/25,000 digital topographic map.

Optimum Management Plan of Swine Wastewater Treatment Plant for the Removal of High-concentration Nitrogen (고농도 질소제거를 위한 축산폐수 처리시설 적정관리 방안)

  • Shin, Nam-Cheol;Jung, Yoo-Jin;Sung, Nak-Chang
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.3
    • /
    • pp.194-200
    • /
    • 2000
  • The amount of swine wastewater reaches about $197,000m^3$ per day at live-stock houses in the whole country. A half of the swine wastewater resources are too small to be restricted legally. This untreated wastewater causes the eutrophication in the water bodies. In case of swine wastewater treatment, the solid-liquid separation must be performed because feces(solid phase) and urine(liquid phase) have large differences in nitrogen and phosphorus concentration. It is necessary to assess exactly the concentration of the pollutants in swine wastewater for planning the wastewater treatment facilities. A full-scale operation was carried out in K city and the plant is consists of conventional plant, the supplementary flocculation basin of chemical treatment process and $anaerobic{\cdot}aerobic$ basin for nitrogen removal. The improved full-scale swine wastewater treatment plant removed the $1,500{\sim}3,000mg/l$ of total-nitrogen(T-N) to 120mg/l of T-N and $131{\sim}156mg/l$ of total-phosphorus(T-P) to $0.15{\sim}1.00mg/l$ of T-N. Accordingly, as a results of operational improvement, the removal efficiencies of T-N and T-P were over $92{\sim}96%$, 99%, respectively. The continuous supply of organic carbon sources and the state of pH played important roles for the harmonious metabolism in anaerobic basin and the pH value of anaerobic basin maintained at about 9.0 for the period of the study.

  • PDF