• 제목/요약/키워드: Small signal analysis

검색결과 585건 처리시간 0.026초

GTO 제어 STATCOM을 포함하는 이산 전력시스템의 RCF 해석법에 의한 진동모드 해석 (Analysis of Oscillation Modes in Discrete Power Systems Including GTO Controlled STATCOM by the RCF Method)

  • 김덕영
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.829-833
    • /
    • 2007
  • In this paper, the RCF method is applied to analyze small signal stability of power systems including GTO controlled parallel FACTS equipments such as STATCOM. To apply the RCF method in power system small signal stability problems, state transition equations of generator, controllers and STATCOM are presented. In eigenvalue analysis of power systems, STATCOM is modelled as the equivalents voltage source model and the PWM switching circuit model. As a result of simulation, the RCF method is very powerful to calculate the oscillation modes exactly after the switching operations, and useful to analyze the small signal stability of power systems with periodically operated switching devices such as STATCOM.

발전량 변화와 미소신호안정도 상정사고 해석 (Contingency Analysis of Small Signal Stability for MW Changes)

  • 심관식;송성근;문채주;김용구;남해곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.139-141
    • /
    • 2002
  • This paper describes a new contingency analysis methods for small signal security assessment based on the eigenvalue perturbation. The eigenvalue perturbation with respect to MW changes can be used to find possible sources of the low frequency oscillation, and to select contingency for small signal stability. The proposed algorithm has been successfully tested on the KEPCO systems.

  • PDF

LLC 공진형 컨버터의 소신호 모델링 분석 및 실험적 검증 (Small Signal Modeling Analysis and Experimental Verification of LLC Resonant Converter)

  • 김진우;이태영;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.365-366
    • /
    • 2017
  • LLC resonant DC-DC converter is widely used in many kinds of applications such as battery energy storage systems, wireless power transfer and high voltage power supply. It is because of characteristics like high efficiency, power density, isolation, wide power level and stability enhancement at high switching frequency. Small signal modeling helps to design controller of the converter by approximating the behavior of nonlinear system with linear state equations. This paper presents comparison between small signal modeling analysis and experimental results of LLC resonant converter.

  • PDF

SOI MOSFET's의 소신호 등가 모델과 변수 추출 (Small signal model and parameter extraction of SOI MOSFET's)

  • 이병진;박성욱;엄우용
    • 전자공학회논문지 IE
    • /
    • 제44권2호
    • /
    • pp.1-7
    • /
    • 2007
  • CMOS 소자의 높은 주파수 특성의 증가로 인하여 높은 주파수 범위에서의 RF와 아날로그 회로 설계가 가능하게 되었다. RF와 아날로그 회로 설계는 실수와 허수의 쌓인 S-파라미터의 특성 분석으로 가능하다. 높은 성능을 활용한 CMOS 기술들은 신뢰도와 밀접한 관계가 있으며, 소자의 열화로 인한 S-파라미터의 변화가 소신호 모델 파라미터들에 미치는 영향을 정확하게 분석하는데 매우 중요하다. S-파라미터의 열화로 인한 다양한 물리적인 현상들 특히 트랜스컨덕턴스와 게이트 커패시턴스의 성능 저하를 자세히 분석하였다. 측정에 사용된 H-gate와 T-gate 소자의 S-파라미터를 0.5GHz에서 40GHz 주파수 범위에서 측정하였으며, 소자의 모든 내부와 외부 파라미터들은 포화영역인 하나의 전압 조건에서 추출하였다. 이 논문은 게이트 구조가 다른 소자에 스트레스를 인가하여 소신호 등가 모델을 추출하였으며, 파라미터들의 변화를 비교 분석한 것이다.

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

초소형 고집적 모바일 커넥터부품 구조해석 (Structural Analysis of High-Density Mobile Micro-Connector)

  • 전용준;신광호;허영무
    • Design & Manufacturing
    • /
    • 제9권2호
    • /
    • pp.1-5
    • /
    • 2015
  • Recently, as small-sized display products such as mobile phones and digital cameras have become lighter and smaller, the size of electric signal delivery part, connector for the mobile display products, also, needs to become smaller, so high-density integration like shortening the distance between signal delivery media, conductors is necessary. With the micro and high-density integration of the connector, it is necessary to maintain contact to a certain degree for keeping intensity and delivering electric signal smoothly to prevent a defect with a specific impact. Accordingly, this study carried out a structural analysis according to the operating mechanisms of 0.16CHP Class Bottom Contact FPC Connector and 0.24CHP Class BTB Connector mostly used in small-sized mobile display products such as mobile phones and digital cameras. As a result of the analysis, both connectors had lower than 997MPa, yield strength of connector material C5240-XSH, so it is judged that permanent plastic deformation would not occur, and that a contact force between the connector and FPC film occurs to a certain degree, so that there would not be any defect in electric signal delivery.

  • PDF

대규모 전력계통의 미소신호 안정도 해석을 위한 Hessenberg법 (Hessenberg Method for Small Signal Stability Analysis of Large Power Systems)

  • 남해곤;송성근;심관식;문채주;김동준;문영환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.168-176
    • /
    • 2000
  • This paper presents the Hessenberg method, a new sparsity-based small signal stability analysis program for large interconnected power systems. The Hessenberg method as well as the Arnoldi method computes the partial eigen-solution of large systems. However, the Hessenberg method with pivoting is numerically very stable comparable to the Householder method and thus re-orthogonalization of the krylov vectors is not required. The fractional transformation with a complex shift is used to compute the modes around the shift point. If only the dominant electromechanical oscillation modes are of concern, the modes can be computed fast with the shift point determined by Fourier transforming the time simulation results for transient stability analysis, if available. The program has been successfully tested on the New England 10-machine 39-bus system and Korea Electric Power Co. (KEPCO) system in the year of 2000, which is comprised of 791-bus, 1575-branch, and 215-machines. The method is so efficient that CPU time for computing five eigenvalues of the KEPCO system is 3.4 sec by a PC with 400 MHz Pentium IIprocessor.

  • PDF

Performance Analysis and Evaluation of Deployment in Small Cell Networks

  • Zheng, Kan;Li, Yue;Zhang, Yingkai;Jiang, Zheng;Long, Hang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권3호
    • /
    • pp.886-900
    • /
    • 2015
  • Small cells are deployed in Heterogeneous Networks (HetNet) to improve overall performance. These access points can provide high-rate mobile services at hotspots to users. In a Small Cell Network (SCN), the good deployment of small cells can guarantee the performance of users on the basis of average and cell edge spectrum efficiency. In this paper, the performance of small cell deployment is analyzed by using system-level simulations. The positions of small cells can be adjusted according to the deployment radius and angle. Moreover, different Inter-Cell Interference Coordination (ICIC) techniques are also studied, which can be implemented either in time domain or in frequency domain. The network performances are evaluated under different ICIC techniques when the locations of Small evolved Nodes (SeNBs) vary. Simulation results show that the average throughput and cell edge throughput can be greatly improved when small cells are properly deployed with the certain deployment radius and angle. Meanwhile, how to optimally configure the parameters to achieve the potential of the deployment is discussed when applying different ICIC techniques.

Modeling and Feedback Control of LLC Resonant Converters at High Switching Frequency

  • Park, Hwa-Pyeong;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.849-860
    • /
    • 2016
  • The high-switching-frequency operation of power converters can achieve high power density through size reduction of passive components, such as capacitors, inductors, and transformers. However, a small-output capacitor that has small capacitance and low effective series resistance changes the small-signal model of the converter power stage. Such a capacitor can make the converter unstable by increasing the crossover frequency in the transfer function of the small-signal model. In this paper, the design and implementation of a high-frequency LLC resonant converter are presented to verify the power density enhancement achieved by decreasing the size of passive components. The effect of small output capacitance is analyzed for stability by using a proper small-signal model of the LLC resonant converter. Finally, proper design methods of a feedback compensator are proposed to obtain a sufficient phase margin in the Bode plot of the loop gain of the converter for stable operation at 500 kHz switching frequency. A theoretical approach using MATLAB, a simulation approach using PSIM, and experimental results are presented to show the validity of the proposed analysis and design methods with 100 and 500 kHz prototype converters.

평균전류모드제어의 전류응답예측을 위한 새로운 이산시간 소신호 모델 (New Discrete-time Small Signal Model of Average Current Mode Control for Current Response Prediction)

  • 정영석
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.219-225
    • /
    • 2005
  • 본 논문에서는 평균전류모드제어를 이용하는 컨버터의 전류응답을 예측할 수 있는 새로운 이산시간 소신호 모델을 구한다. 평균전류모드제어는 최대전류모드제어와 달리 전류제어를 위해 복잡한 보상기 회로를 사용하므로 컨버터의 동작 특성 해석이 어렵다. 평균전류모드제어를 사용하는 컨버터의 소신호 전류응답을 예측하기 위해 샘플러모델을 제안하고, 이 모델로부터 새로운 이산시간 소신호 모델을 구한다. 제안된 방식은 기존 방식과 달리 복잡한 형태의 보상기를 사용하는 컨버터에도 적용 가능하다. 제안한 새로운 이산시간 소신호 모델을 이용한 예측 결과를 스위칭 모델 시뮬레이션 프로그램인 PSIM을 이용한 시뮬레이션 결과 및 실험결과와 비교하여 제안한 새로운 이산시간 소신호 모델의 우수성을 보인다.