• Title/Summary/Keyword: Slurry flow

Search Result 217, Processing Time 0.021 seconds

Slurry Flow Simulation in the Separation Stage of Screw Decanter (스크류 데칸트 분리단 내부에서의 유동 해석)

  • Baek, Yeong-Su;Na, Eun-Su;Park, Jae-Deok
    • 연구논문집
    • /
    • s.31
    • /
    • pp.53-63
    • /
    • 2001
  • Numerical investigation based on the control-volume using finite-difference method has been made by the development of computer program in order to figure out the pattern of the flow field inside screw decanter. The typical flow pattern inside screw decanter is characterized by the two strong recirculation zones separated by the main stream from slurry discharge hole to exit. These recirculation regions and flow pattern are strongly influenced by the centrifugal force and the change of the value of slurry viscosities, that is,500, 1,000 and 3,000cp respectively. The wear of screw decanter appeared experimentally in two spots; one is near the circumferential area of the slurry discharge hole and the other is on the decanter blades at a certain height from the bottom to a different degree after the continuous long-term operation. These wears are partly explained by the flow pattern and the strong turbulence intensity near the recirculation attachment region.

  • PDF

The Heat Exchangers Performance Experiment for a Field Application Ice Slurry Cooling System (현장 적용 아이스슬러리 시스템의 열교환기 성능 실험)

  • Lee, Sang-Hoon;Yoo, Ho-Seon;Lee, Yoon-Pyo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1002-1007
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$). Three kinds of heat exchanger are selected, such as, plate, spiral and shell & tube type, to apply to the ice slurry systems. Experiment was done in the two cases. The first case, circulation water flow fixed at the design conditions for the state to change the flow of the supply of ice slurry. The second case, Ice slurry flow fixed at the design conditions for the state to change the flow of circulation water. Both side of Energy balance was calculated. The performance of plate heat exchanger is higher than others and it's enthalpy effectiveness is higher too.

  • PDF

Heat Transfer Characteristics of Plastic Particle Slurry in a Circular tube Flow (관내 유동 플라스틱 슬러리의 열전달 특성)

  • 김명환;김명준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.451-456
    • /
    • 2004
  • This present experimental study has dealt with the heat transfer characteristics of plastic particle slurry which flows in a circular tube. This type of slurry is suggested for heat transfer enhancement effect cause by random and vortex effect of plastic particle dispersed in water. As a result, the thermal boundary layer becomes thin so the heat transfer coefficient on the tube wall more increase compare to pure water flow. This experimental test section was composed with stainless pipe which has the length of 2000mm, inner pipe diameter of 14mm and outer pipe diameter of 60mm. The most effective and important parameter of this experiment is plastic packing factor(PPF). The focuses of these results are pressure drop and heat transfer coefficient. As results, the friction factor of plastic particle slurry becomes higher at laminar flow region than pure water because of buoyancy effect of plastic particle but the local heat transfer coefficient becomes higher.

Laminar Convective Heat Transfer from a Horizontal Flat Plate of Phase Change Material Slurry Flow

  • Kim Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.779-784
    • /
    • 2005
  • This paper presents the theory of similarity transformations applied to the momentum and energy equations for laminar, forced, external boundary layer flow over a horizontal flat plate which leads to a set of non-linear, ordinary differential equations of phase change material slurry(PCM Slurry). The momentum and energy equation set numerically to obtain the non-dimensional velocity and temperature profiles in a laminar boundary layer are solved. The heat transfer characteristics of PCM slurry was numerically investigated with similar method. It is clarified that the similar solution method of Newtonian fluid can be used reasonably this type of PCM slurry which has low concentration. The data of local wall heat flux and convective heat transfer coefficient of PCM slurry are higher than those of water more than 150$\~$200$\%$, approximately.

Numerical Analysis of a Slurry Flow on a Rotating CMP Pad Using a Two-phase Flow Model

  • Nagayama, Katsuya;Sakai, Tommi;Kimura, Keiichi;Tanaka, Kazuhiro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.8-10
    • /
    • 2008
  • Chemical mechanical polishing (CMP) is a very precise planarization technique where a wafer is polished by a slurry-coated pad. A slurry is dropped on the rotating pad surface and is supplied between the wafer and the pad. This research aims at reducing the slurry consumption and removing waste particles quickly from the wafer. To study the roles of grooves, slurry flows were simulated using the volume of fluid method (two-phase model for air and slurry) for pads with no grooves, and for pads with circular grooves.

Measurement of the Slurry Flow-Field during Chemical Mechanical Polishing (Particle Image Velocimetry 기법을 이용하여, Chemical Mechanical Polishing 공정시 Slurry 유동장 측정)

  • Shin, Sang-Hee;Kim, Mun-Ki;Koh, Young-Ho;Kim, Ho-Young;Lee, Jae-Dong;Hong, Chang-Ki;Yoon, Young-Bin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.125-128
    • /
    • 2004
  • Chemical Mechanical Polishing(CMP) in semiconductor production is characterized its output property by Removal Rate(RR) and Non-Uniformity(NU). Some Previous works shows that RR is determined by production of pressure and velocity and NC is also largely affected by velocity of flow-field during CMP. This study is about the direct measurement of velocity of slurry during CMP and reconstruction whole flow-field by Particle Image Velocimetry(PIV) Techniques. Typical PIV system is tuned adequately for inspecting CMP and Slurry Flow-field is measured by changing both Pad RPM and Carrier RPM. The results show that velocity is majorly determined not by Carrier RPM, but by Pad RPM.

  • PDF

Combined bi-borehole technology for grouting and blocking of flowing water in karst conduits: Numerical investigation and engineering application

  • Pan, Dongdong;Zhang, Yichi;Xu, Zhenhao;Li, Haiyan;Li, Zhaofeng
    • Geomechanics and Engineering
    • /
    • v.29 no.4
    • /
    • pp.391-405
    • /
    • 2022
  • A newly proposed grouting simulation method, the sequential diffusion solidification method was introduced into the numerical simulation of combined bi-borehole grouting. The traditional, critical and difficult numerical problem for the temporal and spatial variation simulation of the slurry is solved. Thus, numerical simulation of grouting and blocking of flowing water in karst conduits is realized and the mechanism understanding of the combined bi-borehole technology is promoted. The sensitivity analysis of the influence factors of combined bi-borehole grouting was investigated. Through orthogonal experiment, the influences of proximal and distal slurry properties, the initial flow velocity of the conduit and the proximal and distal slurry injection rate on the blocking efficiency are compared. The velocity variation, pressure variation and slurry deposition phenomenon were monitored, and the flow field characteristics and slurry outflow behavior were analyzed. The interaction mechanism between the proximal and distal slurries in the combined bi-borehole grouting is revealed. The results show that, under the orthogonal experiment conditions, the slurry injection rate has the greatest impact on blocking. With a constant slurry injection rate, the blocking efficiency can be increased by more than 30% when using slurry with weak time-dependent viscosity behavior in the distal borehole and slurry with strong time-dependent viscosity behavior in the proximal borehole respectively. According to the results of numerical simulation, the grouting scheme of "intercept the flow from the proximal borehole by quick-setting slurry, and grout cement slurry from the distal borehole" is put forward and successfully applied to the water inflow treatment project of China Resources Cement (Pingnan) Limestone Mine.

The Effect of Slurry flow Rate and Temperature on CMP Characteristic (슬러리 온도 및 유량에 따른 CMP 연마특성)

  • 정영석;김형재;최재영;정해도
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.46-52
    • /
    • 2004
  • CMP (Chemical-Mechanical Polishing) is a process in which both chemical and mechanical mechanisms act simultaneously to produce the planarized wafer. CMP process is an extensive usage and continuing high growth rates in the semiconductor industry. The understanding of the process, however, is much slower. The nature of material removal from the wafer is still undefined and ambiguous. Material removal rate according to the slurry flow rate is also undefined and ambiguous. Thus, in this study, the basic mechanism of material removal rate as slurry flow rate is defined in terms of energy supply and energy loss.

Experimental Study on Flow Patterns and Pressure Drop Characteristics of Ice Slurry In Small Size Pipe (1) (소구경 배관내 아이스슬러리의 유동형상 및 압력강하 특성에 관한 실험적 연구(1))

  • 이동원;윤찬일;윤응상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.385-390
    • /
    • 2002
  • To clarify the hydraulic characteristics of ice slurry which made from 6.5% ethylene glycol-water solution flowing through circular pipes of small diameter, experimental studies were performed. The flow pattern was observed and the pressure drop was measured in acrylic pipes with inner diameter of 24 mm. The results of flow visualization revealed that ice particles flowed along the top of pipes in the ranges of small ice fraction and low flow rate, while Ice particles diffused into the whole region of pipes flowed like a homogeneous flow for high flow rate and high ice fraction. An increase in frictional pressure drop was measured as the ice fraction increased in all pipes and unstable flow was observed for up-ward vertical pipe.

Ice slurry transporting and branching characteristics for the district cooling (지역냉방을 위한 아이스슬러리 시스템의 수송 및 분기 특성)

  • Lee, Sang-Hoon;Yoo, Ho-Seon;Lee, Yoon-Pyo;Lee, Chang-Jun;Kwon, Hyeok-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.662-667
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$), and the pumping power and branching characteristics are measured by transporting of the ice slurry. The ice slurry transporting pipe is as long as 200 m. For the same cooling load, the higher IPF is, the lower the transporting flow rate and the pumping power are. But when the IPF is higher than 15%, no less decrease of the pumping power does happen. For the branching characteristics, through the branch pipe where the flow resistance is higher, the higher IPF is measured. A little higher IPF is measured at the thermal expansion branch.

  • PDF