• 제목/요약/키워드: Slit Plate

검색결과 96건 처리시간 0.024초

슬릿 유전체 장벽을 갖는 선대 평판형 방전장치의 방전 및 오존 발생특성 (Discharge and Ozone Generation Characteristics of a Wire-Plate Discharge System with a Slit Barrier)

  • 문재덕;정재승
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.421-426
    • /
    • 2005
  • A wire-plate discharge system with a slit barrier has been proposed and investigated experimentally by focusing on the discharges on the slit barrier and ozone generation characteristics. This wire-plate discharge system with a slit barrier can generate an intensive corona discharges, and produce corona discharge twice, once from the corona wire electrode and second time from the surface and the slits of the slit dielectric barrier. As a result this propose wire-plate discharge system with the slit barrier can produce greatly increased ozone than without the slit barrier. This type of wire-plate discharge system with the slit barrier could be used for effective ozone generation as a means with retard to the removal of pollutant gas

평행평판도파관의 좁은 슬릿을 통한 결합에 있어서 등가어드미턴스 및 복소전력 (Equivalent Admittance and Complex Powers in a Coupling through a Narrow Slit in a Parallel-Plate Waveguide)

  • 이종익
    • 한국정보통신학회논문지
    • /
    • 제13권10호
    • /
    • pp.2059-2065
    • /
    • 2009
  • 본 연구에서는 윗면에 횡방향 슬릿을 갖는 단락종단된 평행평판도파관에 TEM파가 입사되는 경우를 고려하였다. 슬릿의 폭이 좁은 경우에 대한 슬릿의 등가어드미턴스를 구하고 슬릿영역근처에서 복소전력의 변화를 관찰하였다. 특히, 슬릿근처에 존재하는 근접 도체산란체와의 결합에 의해 도파관 외부로의 결합전력이 최대가 되는 경우에 있어서 슬릿 양단의 전압과 도파관 내외부 복소전력에 관한 조건을 점검하였다.

플랜지된 평행평판도파관으로 급전된 슬릿의 등가 어드미턴스 및 좁은 슬릿을 통한 최대결합 메커니즘 (Equivalent Admittance of a Slit Fed by a Flanged Parallel-Plate Waveguide and Maximum Coupling Mechanism through a Narrow Slit)

  • 이종익;김강욱;조영기
    • 한국전자파학회논문지
    • /
    • 제15권11호
    • /
    • pp.1116-1122
    • /
    • 2004
  • 플랜지된 평행 평판 도파관의 슬릿을 통한 전자기적인 결합문제를 고려하였다. 결합 슬릿 근처 도파관 내 $.$외부의 무효전력을 반영한 슬릿의 등가 어드미턴스를 구하고, 슬릿의 폭이 매우 좁은 경우에서의 최대결합 메커니즘을 규명하였다. 도파관의 높이, 슬릿의 폭 및 슬릿의 변위 등과 같은 구조적인 파라미터들이 복사 특성에 미치는 영향을 관찰하였다.

직립 슬릿판에 의한 반사율과 투과율 해석 (On an Analysis of Reflection and Transmission Coefficients by a Vertical Slit Plate)

  • 조일형;김남형
    • 한국해양공학회지
    • /
    • 제16권3호
    • /
    • pp.1-7
    • /
    • 2002
  • In this paper, a numerical model to analyze the performance of a vertical slit-type wave absorber is developed under the assumption of inviscid water waves. The formulation combines the linear potential theory with a semi-empirical description of the eddy-shedding at a slit-type wave absorber. We investigated the reflection coefficients over a wide frequency range for a vertical slit-type wave absorber both with and without a solid rear wall. Model test was conducted at KRISO' s two dimensional wave tank to validate the theoretical results. It is found that the agreement between theoretical results and experimental data is surprisingly good. We found that the wave absorbing system using a vertical slit plate has sufficient potentials for breakwaters for ocean development.

3전극이 부설된 틈새 장벽방전형 플라즈마장치의 코로나 방전 및 오존발생 특성 (Corona Discharge and Ozone Generation Characteristics of a Slit Dielectric Barrier Discharge Type Plasma Reactor with a Third Electrode)

  • 문재덕;정재승
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.583-587
    • /
    • 2007
  • Corona discharge and ozone generation characteristics of a slit dielectric barrier discharge type wire-plate plasma reactor with a third electrode have been investigated. When a third electrode is installed on a slit of the slit barrier, where an intense corona discharge occurs, it is found that a significantly increased ozone output could be obtained. This, however, indicates that the third electrode can activate the corona discharges both of the discharge wire and the slit of the slit barrier in the plasma reactor. As a result, a thin stainless wire, used as the third electrode has a strong effect to influence the corona discharge of the slit and corona wire, especially to the negative corona discharge. Higher amounts of the output ozone and ozone yield, about 1.27 and 1.29 times for the negative corona discharge, can be obtained with the third electrode, which reveals the effectiveness of the third electrode.

A Study on the Coupling of a Flanged Parallel-Plate Waveguide to a Slit In a Nearby Conducting Screen for Near-Field Scanning Microscopy

  • Lee, Jong-Ig;Cho, Young-Ki
    • Journal of electromagnetic engineering and science
    • /
    • 제9권2호
    • /
    • pp.105-109
    • /
    • 2009
  • The problem of electromagnetic coupling between a slit fed by a flanged parallel-plate waveguide(PPW) and a slit in an infinite nearby conducting screen parallel to the flanged ground conductor is studied as a simplified problem for a near-field scanning microscopy(NSM). The method of moments isused to solve the coupled integral equations for the electric field distributions over the slits. The performance of the proposed apparatus as an NSM is tested by examining the effects of some geometrical parameters on the equivalent slit admittance and coupled powers through the slits.

도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구 (A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels)

  • 구태용;김용민;홍정희;황정호
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

Seismic behavior of beam-to-column connections with elliptic slit dampers

  • Shahri, Saeed Farahi;Mousavi, Seyed Roohollah
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.289-301
    • /
    • 2018
  • The rigid steel connections were suffered severe damage because of low rotational capacity during earthquakes. Hence, many investigations have been conducted on the connections of steel structures. As a solution, steel slit dampers were employed at the connections to prevent brittle failure of connections and damage of main structural members. Slit damper is a plate or a standard section with a number of slits in the web. The objective of this paper is to improve the seismic performance of steel slit dampers in the beam-to-column connection using finite element modeling. With reviewing the previous investigations, it is observed that slit dampers were commonly fractured in the end parts of the struts. This may be due to the low participation of struts middle parts in the energy dissipation. Thus, in the present study slit damper with elliptic slits is proposed in such a way that end parts of struts have more energy absorption area than struts middle parts. A parametric study is conducted to investigate the effects of geometric parameters of elliptic slit damper such as strut width, strut height and plate thickness on the seismic performance of the beam-to-column connection. The stress distribution is improved along the struts in the proposed slit damper with elliptic slits and the stress concentration is decreased in the end parts of struts. The average contributions of elliptic slit dampers, beam and other sections to the energy dissipation are about 97.19%, 2.12% and 0.69%, respectively.

Optimal distribution of steel plate slit dampers for seismic retrofit of structures

  • Kim, Jinkoo;Kim, Minjung;Eldin, Mohamed Nour
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.473-484
    • /
    • 2017
  • In this study a seismic retrofit scheme for a building structure was presented using steel plate slit dampers. The energy dissipation capacity of the slit damper used in the retrofit was verified by cyclic loading test. Genetic algorithm was applied to find out the optimum locations of the slit dampers satisfying the target displacement. The seismic retrofit of the model structure using the slit dampers was compared with the retrofit with enlarging shear walls. A simple damper distribution method was proposed using the capacity spectrum method along with the damper distribution pattern proportional to the inter-story drifts. The validity of the simple story-wise damper distribution procedure was verified by comparing the results of genetic algorithm. It was observed that the capacity-spectrum method combined with the simple damper distribution pattern leaded to satisfactory story-wise distribution of dampers compatible with the optimum solution obtained from genetic algorithm.

근접주사현미경의 관점에서 플랜지된 평행평판 도파관과 근접도체스트립과의 결합에 관한 연구 (A Study on the Coupling of a Flanged Parallel-Plate Waveguide to a Nearby Conducting Strip from the Viewpoint of Near-Field Scanning Microscopy)

  • 이종익;고지환;조영기
    • 한국정보통신학회논문지
    • /
    • 제13권11호
    • /
    • pp.2260-2266
    • /
    • 2009
  • 본 논문에서는 플랜지된 평행평판도파관으로 급전된 슬릿과 이에 평행하고 근접하는 도체 스트립과의 전자기적인 결합문제를 단순화된 근접주사현미 경의 관점에서 연구하였다. 슬릿의 등가어드미턴스, 슬릿근처 도파관 내부 및 외부의 무효전력, TEM파 전압반사계수의 크기 및 위상 등의 변화결과로부터 플랜지된 평행평판도파관의 특성을 조사하였다. 제안된 구조의 근접주사현미경으로서의 성능을 다양한 구조적인 파라미터들(도파관 높이, 슬릿의 폭, 스트립의 폭, 슬릿과 스트립 간격, 슬릿 폭과 도파관 높이의 비)이 TEM파 전압반사계수의 크기와 위상에 미치는 영향을 관찰하여 점검하였다. 슬릿으로부터 스트립의 변위에 따른 전압반사계수의 변화결과로부터 도파관의 높이가 작을 때 보다 높은 주사해상도를 얻을 수 있음과 반사계수의 크기 변화에 비해 위상변화가 훨씬 민감함을 확인하였다.