• Title/Summary/Keyword: Slip measurement

Search Result 133, Processing Time 0.023 seconds

Mechanical Bar Anchorage of the PC Beam in Beam-Column Joint Using Plates and Bolts (지지대 및 제결볼트를 이용한 프리캐스트 콘크리트 골조구조의 보 하단 철근 정착공법 개발)

  • 유영찬;최근도;김긍환;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.539-544
    • /
    • 2000
  • The purpose of this study is to develop the mechanical anchorage, namely MAB-BOP (Mechanical Anchorage of 90$^{\circ}$ Hooked Bars with BOlt nad Plate) of the beam-column joint in precast concrete framed structures. Six specimens simulating typical interior beam-column joints were tested to investigate the mechanical characteristics of MAB-BOP. Of primary interest was the measurement of the slip of the anchored bar. Th load-slip curve obtained from this test were used to compare the mechanical performances of the different anchoring methods. Based on the test results, it was found that MAB-BOP showed sufficient anchoring strength capacity compared to 90$^{\circ}$ hooked bar method. So, MAB-BOP can be used as the anchoring methods of the reinforcing bars in PC beam-column joint.

  • PDF

Investigating loading rate and fibre densities influence on SRG - concrete bond behaviour

  • Jahangir, Hashem;Esfahani, Mohammad Reza
    • Steel and Composite Structures
    • /
    • v.34 no.6
    • /
    • pp.877-889
    • /
    • 2020
  • This work features the outcomes of an empirical investigation into the characteristics of steel reinforced grout (SRG) composite - concrete interfaces. The parameters varied were loading rate, densities of steel fibres and types of load displacement responses or measurements (slip and machine grips). The following observations and results were derived from standard single-lap shear tests. Interfacial debonding of SRG - concrete joints is a function of both fracture of matrix along the bond interface and slippage of fibre. A change in the loading rate results in a variation in peak load (Pmax) and the correlative stress (σmax), slip and machine grips readings at measured peak load. Further analysis of load responses revealed that the behaviour of load responses is shaped by loading rate, fibre density as well as load response measurement variable. Notably, the out-of-plane displacement at peak load increased with increments in load rates and were independent of specimen fibre densities.

Experimental Setup for Dynamic Analysis and Verification of Model Trains (모형기차의 동역학 해석 검증을 위한 실험장치 구성)

  • Tak, Tae-Oh;Kim, Suc-Tae
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.95-103
    • /
    • 2000
  • A model trains must have similitude with its original model not only in shape but also in motion. Motion characteristics of a model train under considerations are maximum velocity in straight and circular tracks and stopping distance. Equations of motions are derived to obtain maximum speed and stopping distance based on the Newton's Second Law and the energy principal. To accurately predict traction and resistance force between wheel and rail. wheel slip, or creepage, is taken into consideration. To verify the equations of motion, various experiments have been carried out including measurement of gear efficiency, location of mass center, rolling resistance force, traction force, slip, maximum velocity and stopping distance. This paper addresses how the experiments are setup and carried out in detail. Also the results of experiments are compared with the analytical prediction, which showed good agreements with each other.

  • PDF

A Study on the Design Verification by Using Finite Elements Method and Quality Improvement of Radar by Managing Change Points of 4M (유한요소 기법을 활용한 설계검증 및 4M 변경점 관리를 통한 레이더장비 품질 신뢰성 확보에 관한 연구)

  • Jo, Hee Jin;Pak, Se Jin;Lee, Nam Ho;Jung, Won Yong
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.437-451
    • /
    • 2019
  • Purpose: The purpose of this study is to improve the quality of the PGM system by improving the structure and production process of slip-ring rotary joint for radar. Methods: The improvement measures for each cause are established through failure analysis of broken items. Specifically, changing in the housing to improve the heating system. Changing the transportation method to prevent damage to equipment during transport. Changing work process of the attenuator ring to prevent damage. etc. Results: The results of this study are as follows; improving the heating system reduces heat generated by the attenuator by about 7 degrees and obtain additional temperature margins. Reduction of defect rate because of adding X-band rotary joint run-out measurement test, ESS of slip-ring rotary joint and Transportation improvement(reinforced flight boxes, tube protection, etc). Getting stable VSWR values by improving work process of attenuator overheating due to a bad bonding process. Conclusion: Through this study, improvements were made to slip-ring rotary joint that failed repeatedly for various reasons. As a result of the application of the improvements, the same fault does not occur until now, so we can see that the quality of PGM has improved.

A Study on the Design of a Double Cantilever Structure Friction Tester for Precision Friction Measurement (정밀 마찰측정을 위한 이중 캔틸레버 구조 마찰시험기의 설계에 관한 연구)

  • Kang, Won-Bin;Kim, Hyun-Joon
    • Tribology and Lubricants
    • /
    • v.34 no.4
    • /
    • pp.125-131
    • /
    • 2018
  • A precision tribometer consisting of a cantilever was designed to measure frictional forces in the micro-Newton range. As frictional forces are measured based on the bending of the cantilever, vibration of the cantilever is the most significant factor affecting the quality of the friction measurement. Therefore, improved design of the tribometer with double cantilevers and a connecting plate that united the two cantilevers mechanically was suggested. For the verification of the modified design of the tribometer, numerical analysis and experiments were conducted. Examination using the finite element method revealed that the tribometer with a double cantilever and a connecting plate exhibited faster damping characteristics than the tribometer with a single cantilever. In the experiment, effectiveness of the double cantilever and connecting plate for vibration reduction was also confirmed. Vibration of the tribometer with double cantilever decreased eight times faster than that of the tribometer with a single cantilever. The faster damping of the double cantilever design is attributed to the mechanical interaction at the contacting surfaces between the cantilever and the connecting plate. Tribotesting using the tribometer with a single cantilever resulted in random fluctuation of frictional forces due to the stick-slip behavior. However, using the tribometer with a double cantilever and connecting plate for the tribotest gave relatively uniform and steady measurement of frictional forces. Increased stiffness owing to using a double cantilever and mechanical damping of the connecting plate were responsible for the stable friction signal.

An Experimental Study on Selecting the Diameter of Probe Stylus of a Coordinate Measuring Machine in Measuring the Edge Profile of High Pressure Compressor (압축기 블레이드의 Edge 형상 측정시 3차원 측정기의 탐침 볼 직경 선정을 위한 실험적 연구)

  • Joung, Soo-Ho;Byun, Jai-Hyun
    • IE interfaces
    • /
    • v.15 no.4
    • /
    • pp.432-438
    • /
    • 2002
  • When the trailing edge and leading edge of an airfoil contour of high pressure compressor blades are measured, there exists a measurement error due to the size of the probe stylus ball diameter. In the paper an experimental study is provided to determine the optimum diameter of the probe stylus in inspecting the airfoil of the high pressure compressor blade. The measurement and analysis procedure suggested in this paper will be helpful to those who are involved in measuring and inspecting various types of blades.

Image Quality Evaluation for the Railway Abrasion Measurement with a High Resolution (고해상도 레일 마모도 측정을 위한 영상 평가)

  • Ahn, Sung-Hyuk;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.887-894
    • /
    • 2009
  • There is no standard rule for the test of the railway abrasion measurement system composed of the line laser and the camera. This paper is proposed of the method to estimate the performance of the railway abrasion measurement system. The performance estimation is achieved by the quantitative analysis parameters such as MTF, NPS and DQE.

Effect of Wall Groove Characteristics on Yield Stress Measurement of Magnetorheological Fluid

  • Tian, Zuzhi;Guo, Chuwen;Chen, Fei;Wu, Xiangfan
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.281-285
    • /
    • 2017
  • To suppress the wall slip effect and improve the yield stress measurement precision of magnetorheological fluid, measurement disks with different grooves are first manufactured. Then, the influence of groove characteristics on the yield stress of magnetorheological fluid is investigated by the method of experiments. Finally, the optimization wall grooves of measurement disks are obtained, and the yield stress of a self-prepared magnetorheological fluid is measured. Results indicate that the groove type and groove width have a slight influence on the shear yield stress, whereas the measured yield stress increases with enhanced groove density, and the optimized groove depth is 0.3 mm. The measured shear yield stress of self-prepared MR fluid can be improved by 18 % according to the optimized grooved disks, and the maximum yield stress can reach up to 65 kPa as the magnetic flux density is 0.5 T.

Reduction of Current Ripples due to Current Measurement Errors in a Doubly Fed Induction Generator

  • Park, Gwi-Geun;Hwang, Seon-Hwan;Kim, Jang-Mok;Lee, Kyo-Beum;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.313-319
    • /
    • 2010
  • This paper proposes a new compensation algorithm for the current measurement errors in a DFIG (Doubly Fed Induction Generator). Generally, current measurement path with current sensors and analog devices has non-ideal factors like offset and scaling errors. As a result, the dq-axis currents of the synchronous reference frame have one and two times ripple components of the slip frequency. In this paper, the main concept of the proposed algorithm is implemented by integrating the 3-phase rotor currents into the stationary reference frame to compensate for the measured current ripples in a DFIG. The proposed algorithm has several beneficial features: easy implementation, less computation time, and robustness with regard to variations in the electrical parameters. The effectiveness of the proposed algorithm is verified by several experiments.

Measurement of the Dynamic Transmission Error of Helical Gears by the Accelerometers (가속도계에 의한 헬리컬 기어의 동적 전달오차의 측정)

  • Kim, Dae-Sik;Cho, Do-Hyun;Park, Chan-Il;Choi, Deo-Kki;Park, Chan-Gook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1720-1727
    • /
    • 2003
  • The object of this work is to develop the measurement method of the transmission error of the helical gears. For this purpose, experimental set up is designed by 3D CAD software. It consists of the motor, inverter, powdered brake equipment, torque sensor and helical gearbox. In this study, tangential linear accelerometers were used as the methods for the transmission error measurement. the acceleration signals are transmitted to the signal conditioners through the slip rings and the transmission errors are obtained by a specially designed circuit board. The transmission errors are analyzed in the frequency domain. As a result, The periodicity of the transmission error is confirmed in the mesh frequency and its harmonics. The magnitude of harmonic components is very dependent on the natural frequencies of the gear system. It usually increases with the rotational speed. However, it does not always increase with torque.