• 제목/요약/키워드: Skull image

검색결과 142건 처리시간 0.025초

해골 이미지를 응용한 여자 청소년 상의(Top)디자인 (Top Design by Skull Image for Female Teenagers)

  • 류경옥
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.123-130
    • /
    • 2012
  • The purpose of this study is to understand Skull Images in fashion trends and Skull Image Top Design for Female Teenagers. The methods of this study are an academic literature review as well as practical study through actual case studies about. The subjects of the study were 53 Female Teenagers who lived in Chuncheon. Data were collected during March, 2009. Statistical analyses used in the study were frequency. An adolescent period, they are rebellious, sensual and syntonic inclination. These days, Lots of Female Teenagers want unique fashion for herself and select Skull Image clothing. But they want fit and pretty style not big-look. In this study, I designed seven pieces of Top blouse while applying Skull Image, an important image of Hip-hop and Punk fashion, and the concepts of the continuance theory to them. This study will make a contribution to the designing of Top for Female Teenagers through reinterpretation of the Hip-hop and Punk fashion. In addition, there are practicable and unique Top design for Female Teenagers.

  • PDF

컴퓨터 시각 인식 기법을 이용한 영상 중첩법에 의한 개인식별 (Image Superimposition for the Individual Identification Using Computer Vision System)

  • Ha-Jin Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제21권1호
    • /
    • pp.37-54
    • /
    • 1996
  • In this thesis, a new superimposition scheme using a computer vision system was proposed with 7 pairs of skull and ante-mortem photographs, which were already identified through other tests and DNA fingerprints at the Korea National Institute of Scientific Investigation. At this computer vision system, an unidentified skull was caught by video-camcoder with the MPEG and a ante-mortem photograph was scanned by scanner. These two images were processed and superimposed using pixel processing. Recognition of the individual identification by anatomical references was performed on the two superimposed images. These results were as followings. 1. For the enhancement of skull and ante-mortem photographs, various image processing schemes, such as SMOOTH, SHARPEN, EMBOSS, MOSAIC, ENGRAVE, INVERT, NEON and COLOR TO MONO, were applied using 3*5 window processing. As an image processing result of these methods, the optimal techniques were NEON, INVERT and ENGRAVE for the edge detection of skull and ante-mortem photograph. 2. Using various superimposition image processing techniques (SRCOR, SRCAND, SRCINVERT, SRCERASE, DSTINVERT, MERGEPAINT) were compared for the enhancement of image recognition. 3. By means of the video camera, the skull image was inputed directly to a computer system : superimposing it on the ante-mortem photograph made the identification more precise and time-saving. As mentioned above, this image processing techniques for the superimposition of skull and ante-mortem photographs simply used the previous approach, In other wrods, taking skull photographs and developing it to the same size as the ante-mortem photographs. This system using various image processing techniques on computer screen, a more precise and time-saving superimposition technique could be able to be applied in the area of individual identification in forensic practice.

  • PDF

CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구 (Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model)

  • 엄기두;이병도
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구 (A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters)

  • 박성우;이종인;이영진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.765-771
    • /
    • 2019
  • Skull X-ray 영상에서 노이즈의 발생은 불가피하며, 이는 영상 화질과 진단 정확도를 저하시키고 디지털 영상 장치의 특성상 오류를 증가시킨다. 이러한 노이즈는 선량을 증가시키면 쉽게 감쇠되긴 하지만 환자가 받는 피폭선량이 더 큰 문제를 야기할 수 있다. 그래서 선량문제를 해결하고 동시에 노이즈를 줄이기 위해저 선량에서 노이즈 감소 알고리즘이 활발히 연구되고 있는데, 초기에 개발되고 널리 사용되어진 median filter와 Wiener filter는 노이즈 감소 효율이 떨어지고 영상경계에 대한 정보가 많이 손실된다는 단점이 있다. 본 연구의 목적은 이전 노이즈 감소효율의 문제점을 보완할 수 있는 total variation (TV) 알고리즘을 skull X-ray 영상에 적용하여 정량적으로 평가하고 비교를 하는 것이다. 이를 위해 Siemens사의 X-ray 장치를 사용하여 성인 skull을 모사할 수 있는 팬텀을 통해 다양한 관전압과 관전류량을 사용하여 실제 skull X-ray 팬텀 영상을 획득하였다. 또한, 각각의 팬텀 영상에 noisy image, median filter, Wiener filter, TV 알고리즘을 적용하였을 때의 대조도 대 잡음비 (CNR)와 변동계수 (COV)를 비교 측정했다. 실험 결과 TV 알고리즘을 적용하였을 때, 모든 조건에서 CNR와 COV 특성이 우수함을 확인할 수 있었다. 결론적으로 이번 연구를 통해 TV 알고리즘을 사용하여 영상의 질을 높일 수 있는지에 대해 확인해 보았고, 이론적으로 CNR 값은 관전류량이 증가할수록 노이즈가 감소함으로 인해 증가하는 것을 알아볼 수 있었다. 반면에, COV는 관전류량이 증가할수록 감소하였으며 관전압이 증가하였을 때 noise는 감소하고 투과량이 증가하여 COV가 감소하는 것을 알아볼 수 있었다.

두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향 (Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography)

  • 김은혜;주영철;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구 (A Study on Dose Reduction in Infant Skull Radiography)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.387-392
    • /
    • 2017
  • 영 유아는 사건, 사고 및 교통사고 또는 질병으로 인해 머리에 골절 및 혈관파열, 피부에 상처를 받아 병원에 내원하여 영상의학과에서 머리 검사인 전 후(Skull AP) 및 측면(Skull LAT) 촬영을 받게 된다. 머리검사에서 성인 머리(Skull) 촬영은 격자를 이용하여 촬영에 적용하면 방사선 2차선을 제거하여 영상의 대조도를 높인다. 그러나 방사선 노출조건 중 관전압을 8~10 kVp 높게 주어야 하며 환자피폭이 증가한다. 본 연구는 영 유아 머리촬영시 격자(grid)를 이용하지 않고 동등한 영상을 얻을 수 있다면 피폭선량 감소 및 Grid Cut off에 의한 아티팩트를 방지할 수 있어 연구해 보았다. 연구자는 방사선계측기 이용 방사선선량을 측정 하고 의료영상평가 방법 중에서 주관적 평가(ROC,receiver operationg characteristic)을 해 보았다. 결과에서 격자를 이용하지 않고 촬영하면 환자 피폭선량 감소와 영상 평가에서도 영 유아의 머리 촬영시 격자를 이용하지 않고 촬영을 하게 되면 머리 전 후촬영에서 0.019 mGy 와 측면촬영 0.02 mGy 피폭선량 감소가 있었고 영상평가에서도 4점을 높게 받았다. 결론으로 병원에 내원한 영 유아 머리촬영은 격자를 이용하지 않고 촬영하면 피폭 선량 감소 및 영상 아티팩트인 Grid Cut off을 방지 할 수 있고 엑스선관 수명이 연장되리라 사료된다.

두부(頭部) X선촬영시(線撮影時) 산란선(散亂線)과 화질(畵質)에 관(關)한 검토(檢討) (A Study on the Image Quality and the Scattered Ray content in the Skull Radiography)

  • 허준;김창균;강홍석;이선숙;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.15-19
    • /
    • 1985
  • The seattered-ray have a bad effect to the image of x-ray film. Therefore, to obtain the better x-ray image, the most important point is to eliminate the scattered-ray, come from the patient, and the easiest method to eliminate the scattered-ray is to use a proper grid for tube voltages. Authors made an experiment on the scattered-ray contents and the image quality in skull radiography, and obtained the results as follows; 1. The scattered-ray content in skull radiography was 83%, but it could be reduced to 35%-50% by using grid. 2. The image contrast was most increased when the using grid ratio was 8:1. 3. The image quality was not influenced by the scattered-ray contents between 32% and 45%.

  • PDF

파노라마방사선사진상과 구외방사선사진상에서의 해부학적 구조에 관한 비교연구 (A COMPARATIVE STUDY OF ANATOMIC STRUCTURES ON THE PANORAMIC RADIOGRAPH AND SOME EXTRAORAL RADIOGRAPHS)

  • 이동규;김한평
    • 치과방사선
    • /
    • 제14권1호
    • /
    • pp.71-80
    • /
    • 1984
  • The author has studied each landmark for successful interpretation in the radiograph of the head that have the complex anatomic structures, using panoramic radiograph, postero-anterior cephalometric radiograph, lateral cephalometric radiograph, Waters' radiograph of the skull. The anatomic structures of the human dry skull attached by radiopaque materials were taken radiographs and analysed comparatively. The results were as follows: 1. The overall anatomic structures of the mandible showed sharp images in the panoramic radiograph than other radiographs with relatively less distortion, superimposition, blurring of the image. 2. The anatomic structures were situated on sagital plane of the skull showed blurred images in panoramic radiograph than other radiographs. 3. The anatomic structures which were situated on the basal portion of the skull showed blurred and secondary images in the panoramic radiograph than other radiographs. 4. In the panoramic radiograph, the lower 3rd portion of the orbit appeared to be superimposed with the superior portion of the maxillary sinus and the medial and lateral surface of the nasal cavity showed extensively superimposition of the orbit and the maxillary sinus, which images showed blurring. 5. The inferior surface and posterior surface of maxillary sinus showed to be good image in the panoramic radiograph than other radiographs. 6. In the panoramic radiograph, line of maxillary bone between lateral pterygoid plate, line of maxillary bone between zygomatic bone showed distinct image with another structures.

  • PDF

전산화단층 촬영상의 임계치가 3차원 의학모델 정확도에 미치는 영향에 대한 연구 (Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model)

  • 이병도;이완
    • Imaging Science in Dentistry
    • /
    • 제32권1호
    • /
    • pp.27-33
    • /
    • 2002
  • Purpose: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model Material and Methods : CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works/sup TM/ 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. Results: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm (2.52%) between linear measurements of dry skull and 800 RP model. Conclusion: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.

  • PDF

Alveolar Soft Part Sarcoma Metastasized to Both the Skull and the Brain

  • Shin, Tae-Hee;Jung, Young-Jin;Kim, Oh-Lyong;Kim, Min-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권1호
    • /
    • pp.55-57
    • /
    • 2012
  • Alveolar soft part sarcoma (ASPS) with skull and brain metastases is extremely rare. A 53-year-old patient diagnosed as skull metastasis of ASPS visited our clinic complaining of an outgrowing scalp mass in spite of radiation therapy. Past medical history revealed that the patient had been diagnosed and treated for ASPS of the thigh 4 years ago. Magnetic resonance imaging revealed a hyperintense ovoid mass on the T2-weighted image, an isointense on the T1-weighted image, and a homogeneous enhanced mass with gadolinium. Another small-sized enhanced mass with mild peritumoral swelling was found at the deep white matter of the left frontal lobe. A gross total resection of the skull lesion with cranioplasty was performed for the surgical defect. A histologic examination of the specimens revealed metastatic ASPS involving the skull. Surgery with a total removal of the lesions may be effective for improving a patient's symptoms especially from neurological dysfunction.