• Title/Summary/Keyword: Skin volume

Search Result 291, Processing Time 0.036 seconds

Novel technique for preventing make up deterioration using performance materials

  • Miyazawa, Masakazu;Nishikata, Kazuhiro;Mohri, Kunihiko
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.370-378
    • /
    • 2003
  • MFD (Make up Film Deterioration) is a gradual deterioration of applied make up and is a common problem experienced by most foundation users. Our investigation revealed that for 64% of all make up users MFD is their greatest consern is using foundations. Known that the primary cause of MFD is sebum secretion. We observed that the length of time prior to onset of MFD in people who produce high level of sebum varies significantly from person to person. This suggests that other factors besides quantity of sebum production can affect MFD. Control over this factor would, we believe, be key to developing longer-lasting makeups. We studied the relationship between MFD and skin surface conditions. Our study revealed that furrows on the skin surface affect MFD significantly. Sebum reaches the skin surface from sebaceous glands and flows along furrow on the skin. If there are many deep furrows, it takes longer for sebum to overflow. But if the furrows are few or shallow, sebum quickly overflows and spreads over the skin surface where it can degrade the make up film. Therefore even when the volume of sebum produced is the same, the rate of MFD will be different depending on the number and shape of the furrows. A longer-lasting foundation could be produced by matching personal skin condition, but this would be very difficult because individual variations in texture are very large. Therefore we approached the problem by attempting to impose sebum resistance in under make up and foundation. We have developed two new materials and make up products based on our theory. A new fluoroalkyl acrylate-methacrylates copolymer designed for incorporation in under make up is extremely sebum resistant and sweat proof. Another new acrylate polymer designed for inclusion in foundation absorbs sebum and changes to a solid. Usage tests confirm it is possible to reduce MFD by using under make up and foundation which incorporate our new materials to cover where skin furrows are few or shallow

  • PDF

Immediate Implant Reconstruction using Silicone Prosthesis in Breast Cancer Patients after Skin Sparing Mastectomy (유방암 환자에서 피부보존 유방절제술 후 실리콘 보형물을 이용한 즉시 유방재건술)

  • Cho, Young-Kyoo;Yang, Jung-Dug;Kim, Gui-Rak;Chung, Ho-Yun;Cho, Byung-Chae;Park, Ho-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.749-757
    • /
    • 2010
  • Purpose: Since skin sparing mastectomy removes the mammary gland and the nipple-areolar complex preserving all mammary skin, it makes the widespread use of implants in immediate reconstruction. This article reports our experience in immediate breast reconstruction after skin sparing mastectomy by using the silicone implants in patients especially who have small to moderate sized and minimal ptotic breast. Methods: From September of 2007 to July of 2009, we performed breast reconstruction for 44 breasts of 40 women with silicone implant after mastectomy. Tumors were divided into 5 malignant types (21 IDC, 18 DCIS, 2 ILC, 2 phylloides tumor, 1 mucinous carcinoma). The implant is placed in a submuscular pocket or in a submuscularsubfascial pocket depending upon the condition of the muscles and skin flaps after mastectomy. Results: The mean age was 47 years and the average follow-up period was 11 months. Cosmetic outcome was assessed by evaluation of photographs and assessment of breast volume and shape, breast symmetry, and overall outcome. About 80% of each of these parameters was scored as good or excellent. Breast complication was developed in a total of 6 cases including 2 capsular contracture, 2 partial skin necrosis due to blue dye injection and 2 implant infection. Conclusion: The use of definitive implants in a skin sparing mastectomy is a one-stage immediate breast reconstruction with low morbidity and acceptable result. This method is considered reliable with favorable aesthetic result.

Skin Dose Comparison of CyberKnife and Helical Tomotherapy for Head-and-Neck Stereotactic Body Radiotherapy

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Purpose: This study conducts a comparative evaluation of the skin dose in CyberKnife (CK) and Helical Tomotherapy (HT) to predict the accurate dose of radiation and minimize skin burns in head-and-neck stereotactic body radiotherapy. Materials and Methods: Arbitrarily-defined planning target volume (PTV) close to the skin was drawn on the planning computed tomography acquired from a head-and-neck phantom with 19 optically stimulated luminescent dosimeters (OSLDs) attached to the surface (3 OSLDs were positioned at the skin close to PTV and 16 OSLDs were near sideburns and forehead, away from PTV). The calculation doses were obtained from the MultiPlan 5.1.2 treatment planning system using raytracing (RT), finite size pencil beam (FSPB), and Monte Carlo (MC) algorithms for CK. For HT, the skin dose was estimated via convolution superposition (CS) algorithm from the Tomotherapy planning station 5.0.2.5. The prescribed dose was 8 Gy for 95% coverage of the PTV. Results and Conclusions: The mean differences between calculation and measurement values were $-1.2{\pm}3.1%$, $2.5{\pm}7.9%$, $-2.8{\pm}3.8%$, $-6.6{\pm}8.8%$, and $-1.4{\pm}1.8%$ in CS, RT, RT with contour correction (CC), FSPB, and MC, respectively. FSPB showed a dose error comparable to RT. CS and RT with CC led to a small error as compared to FSPB and RT. Considering OSLDs close to PTV, MC minimized the uncertainty of skin dose as compared to other algorithms.

Study on Analysis of RTM Process to Manufacture Bogie Frame Skin Depending on Thickness (대차 프레임 스킨의 두께에 따른 RTM 공정 특성 분석 연구)

  • Kim, Moosun;Kim, Jung-Seok;Kim, Seung Mo
    • Composites Research
    • /
    • v.28 no.6
    • /
    • pp.372-377
    • /
    • 2015
  • In this study, we analyzed process numerically when a bogie frame skin is manufactured by applying resin transfer molding process using composite material instead of steel. Processing time was compared based on the various thickness of bogie frame skin and the weight variation of a skin was also considered. As a result, RTM processing time decreases and the weight of a bogie reduces as the thickness of frame skin increases with the assumption that fiber volume is constant inside the skin. By considering these results as the information to estimate the production cost, trade-off between two fields, processing time and structural properties, can be performed in design optimization to produce bogie frame.

SERRATION MECHANISM OF AA5182/POLYPROPYLENE/AA5182 SANDWICH SHEETS

  • Kim, K.J.
    • International Journal of Automotive Technology
    • /
    • v.7 no.4
    • /
    • pp.485-492
    • /
    • 2006
  • The AA5182/polypropylene/AA5182(AA/PP/AA) sandwich sheets have been developed for application to automotive body panels in future lightweight vehicles with significant weight reduction. It has been reported that the AA5182 aluminum sheet shows $L\"{u}ders$ band because of dissolved Mg atoms that cause fabrication process problem, especially surface roughness. The examination of serration behavior has been made after the tensile deformation of the AA/PP/AA sandwich sheets as well as that of the AA5182 aluminum skins at room and elevated temperatures. All sandwich sheets and the AA5182 aluminum skin showed serration behavior on their flow curves. However, the magnitude of serration was significantly diminished in the sandwich sheet with high volume fraction of the polypropylene core. According to the results of the analysis of the surface roughness following the tensile test, $L\"{u}ders$ band depth of the sandwich sheet evidently showed lower than that of the AA5182 aluminum skin. The strain rate sensitivity, m-value, of the AA5182 aluminum skin was -0.006. By attaching these skins to the polypropylene core, which has relatively large positive value of 0.050, m-value of the sandwich sheets changed to the positive value. The serration mechanism of the sandwich sheets was quantitatively investigated in the point of the effect on polypropylene thickness variation, that on the strain rate sensitivity and that on the localized stress state.

A Study on the Flows in a Concentric Annulus with rotating inner cylinder (안쪽축이 회전하는 환형관내 유동연구)

  • Kim Young-Ju;Woo Nam-Sub;Kwon Hyuk-Jung;Hwang Young-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.337-340
    • /
    • 2002
  • The present experimental and numerical investigations are performed for the characteristics of transitional flow in a concentric annulus with a diameter ratio of 0.52, whose outer cylinder is stationary and inner one rotating. The flow field of an annulus has been numerically solved using a finite volume method. The pressure losses and Skin-friction coefficients have been measured for the fully developed flow of water and $0.2{\%}$ aqueous solution of sodium carboximethy1 cellulose (CMC), respectively at inner cylinder rotational speed of $0{\~}600rpm$. The transitional flow has been examined by the measurement of pressure losses to reveal the relation of the Reynolds and Rossby numbers with the skin-friction coefficients. The occurrence of transition has been checked by the gradient changes of pressure losses and skin-friction coefficients with respect to the Reynolds numbers. Consequently the critical(axial-flow) Reynolds number decreases as the rotational speed increases. Thus, the rotation of inner cylinder promotes the early occurrence of transition due to the onset of Taylor vortices.

  • PDF

Secondary contouring of flaps

  • Kim, Tae Gon;Choi, Man Ki
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.319-324
    • /
    • 2018
  • Perforator flaps are becoming increasingly common, and as primary thinning techniques are being developed, the need for secondary contouring of flaps is decreasing. However, many reconstructive flap procedures still incorporate secondary debulking to improve the functional and aesthetic outcomes. Direct excision, liposuction, tissue shaving with an arthroscopic cartilage shaver, and skin grafting are the four major methods used for secondary debulking. Direct excision is primarily applied in flaps where the skin is redundant, even though the volume is not excessive. However, due to the limited range of excision, performing a staged excision is recommended. Liposuction can reduce the amount of subcutaneous tissue of the flap and protect the vascular pedicles. However, the main drawback of this method is its limited ability to remove fibrotic tissues, for which the use of a shaver may be more convenient. The main drawback of using a shaver is that it is difficult to simultaneously remove excess skin. Skin grafting enables the removal of sufficient excess tissue to recover the contour of the normal limb and to improve the color match, facilitating excellent aesthetic results.

Color Analysis of Forehead Flap and Full Thickness Skin Graft in Facial Reconstruction (이마피판술과 후이개부 전층피부이식술을 이용한 안면부 연부조직결손 재건 후 피부 색상의 비교)

  • Cho, Sung Hoo;Yoo, Sung In;Noh, Bok Kyun;Kim, Eui Sik;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Purpose: For facial reconstruction, skin color match is crucial to achieve great aesthetic result. Forehead flap and full thickness skin graft have been used for many years to reconstruct facial defect. Their results are aesthetically valuable with remarkable resemblance and harmony of the skin color between donor and recipient sites. The purpose of this study is to evaluate and compare the aesthetic outcome of the two methods as the analysis of skin color match. Methods: From January 1995 to December 2005, ten forehead flaps and ten full thickness skin grafts were performed. The reconstructed areas of forehead flaps were five noses and five eyelids. Recipient sites of full thickness skin grafts were seven eyelids, two noses and one forehead. In order to obtain the objective validity, the skin color of flap(or graft) and the recipient sites were measured by chromameter. The skin colors were quantified according to a three-dimensional coordinate system used in chromameter, L*(brightness), a*(redness), and b*(yellowness).Results: There was no significant color difference between forehead flap site and adjacent skin in all color values. On the other hand, the L* and b* values of graft sites were significantly lower than those of the adjacent skins. The a* values of graft sites were higher than those of the adjacent skins. Conclusion: This study reveals that skin color match of forehead flap is greater than that of full thickness skin graft. As forehead flap has adequate volume and great color match, it can be useful to reconstruct deep facial defect such as nasal defect. On the other hand, full thickness skin graft can be used for superficial defect like partial eyelid defect.

A Study on Character analysis and make up design in TV action drama 'ya-cha(夜叉)'

  • Kim, Yuk-Young;Shin, Sae-Young
    • Journal of Fashion Business
    • /
    • v.16 no.3
    • /
    • pp.63-77
    • /
    • 2012
  • This study action drama TV drama 'Ya-ha'(夜叉) the actual work practices of the pre-consultation stage through the Writers, Producer, Art directors and in consultation with the opinion of the character set the record of the contents and character changes over time in accordance with characters makeup the design elements were analyzed. The methods of study was used local and abroad related books, studies, publications and cases and the subjects were limited to be four male make up characters in drama 'Ya-cha'. As a result, TV action drama 'Ya-cha' make up design elements and representation techniques were classified as description of skin tone, wound, the shape of eyebrows, hair type, shape of beard and materials and carried out an important role in the character representation. First, presentation techniques changed skin tones depending on character and position and described wound shape as expression technique and materials were analyzed. Second, the shape of eyebrows was based on the physiognomy of the form. And hair type changed volume, thickness, length and texture depending on character. Third, shape of beard is expressed different kinds of volume, thickness, length and texture depending on character. There fore, that systematization of the make-up design elements is useful to express stable characters and make drama for make up in various image genres.

Investigation of the electric currents on the skin of twelve meridian collaterals' meridian points below the elbow-knee joints ( I ) (십이경맥중(十二經脈中) 주슬관절이하(?膝關節以下) 경혈(經穴)의 생체전류량(生體電流量) 측정(測定) ( I ))

  • Jeon, Byeong-Hun;Kim, Jae-Hyo;Son, In-Cheol;Jeong, Dong-Myeong;Hwang, Geun-Chang;Jeong, U-Yeol
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.84-110
    • /
    • 1996
  • Meridian collateral and meridian points have been the base of acupuncture and moxibustion therapy. Also the theory have composed the main portion of Oriental Medicine. But the mechanism and scientific background has not been completely eatablished, and the research on the objectification of diagnosis of meridian collateral and meridian points, and acupuncture & moxibustion therapy has been necessary nowadays. A new understanding of value of Oriental Medicine has been increasing, the scientific understanding of meridian collateral and meridian points should have been examined. The system of meridian collateral and meridian points was very interesting topics between the scientists in the world. Especially, the elucidation of function and mechanism of Qi(氣) was very important in the scientific theme of 21th century. But there has been many difficulties in the study of meridian collateral and meridian points, since the system of meridian collateral and meridian points has the complexed function and vague structure in the organism. As the one of index of meridian points, the electric current has been used. In this report, the volume of electric current on the skin around the meridian points was investigated. The results of investigation showed the meridian points have higher electric current volume than non-meridian points.

  • PDF