• Title/Summary/Keyword: Skin occlusion

Search Result 47, Processing Time 0.03 seconds

Construction of Skin Color Map for Resolving Hand Occlusion in AR Environments (증강현실 환경에서 손 가림 해결을 위한 피부 색상 정보 획득)

  • Park, Sang-Jin;Park, Hyungjun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.2
    • /
    • pp.111-118
    • /
    • 2014
  • In tangible augmented reality (AR) environments, the user interacts with virtual objects by manipulating their physical counterparts, but he or she often encounters awkward situations in which his or her hands are occluded by the augmented virtual objects, which causes great difficulty in figuring out hand positions, and reduces both immersion and ease of interaction. To solve the problem of such hand occlusion, skin color information has been usefully exploited. In this paper, we propose an approach to simple and effective construction of a skin color map which is suitable for hand segmentation and tangible AR interaction. The basic idea used herein is to obtain hand images used in a target AR environment by simple image subtraction and to represent their color information by a convex polygonal map in the YCbCr color space. We experimentally found that the convex polygonal map is more accurate in representing skin color than a conventional rectangular map. After implementing a solution for resolving hand occlusion using the proposed skin color map construction, we showed its usefulness by applying it to virtual design evaluation of digital handheld products in a tangible AR environment.

Effect of Occlusion on the Activities of Dermal Xanthine Oxidase in Rats (흰쥐에 있어서 피부노출 차단이 피부조직의 Xanthine Oxidase 활성에 미치는 영향)

  • 한선일;전태원;윤종국
    • Biomedical Science Letters
    • /
    • v.6 no.1
    • /
    • pp.37-43
    • /
    • 2000
  • To investigate an impact of skin occlusion on the dermal xanthine oxidase (XO) activity, the dorsal part in rats was covered with closed petri dish-shaped chamber, 46 mm in diameter and 10 mm in height, which was made of glass. The crack between top of chamber and skin was sealed by an adhesive agent. After 5 days, the quantity of sweat accumulation was about 400 mg, whereas after 10 days that was decreased about to 21 mg. The 5 days skin occlusion showed the more increased activity of dermal XO compared with the control, and the increased ratio of enzyme activity to the control was higher than that of 10 days skin occlusion, with the increase being associated with sweat accumulation in chamber. Furthermore, the V$_{max}$ of dermal XO in 5 days skin occlusion was higher than that in the control. In conclusion, it may be hypothesized that the XO system may play an role for defence mechanism in dermal tissue.

  • PDF

Enhanced Occlusiveness of Nanostructured Lipid Carrier (NLC)-based Carbogel as a Skin Moisturizing Vehicle

  • Choi, Woo-Sik;Cho, Hye-In;Lee, Hyun-Young;Lee, Seo-Hyun;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.6
    • /
    • pp.373-378
    • /
    • 2010
  • In order to develop a topical preparation which has a high occlusive property with skin moisturization, nano-structured lipid carrier (NLC) systems along with solid lipid nanoparticle (SLN) were designed. Various NLC dispersions were successfully formulated with Compritol 888 ATO as a solid lipid, Labrafil M 1944 CS as an oil, and Tween 80 as a surfactant. The increase of oil content (5 to 50%) led to the decrease in the occlusion factor in the order of SLN > NLC-5 > NLC-15 = NLC-30 > NLC-50. Particle size of lipid particulates was in the range of 100 to 160 nm. NLC-based carbogels were prepared by the employment of humectants such as urea, glycerin, and Tinocare GL to carbomer gel. NLC-30 gel formulations containing 4 or 8 % of lipid particles showed improved occlusive effect in vitro, compared to NLC-free gel base. Even though NLC-free gel base revealed comparable occlusion effect by itself, the occlusion factor of 4 % NLC-30 gel was about 2-fold higher than that of NLC-free gel base.

The use of laser Doppler blood flow to assess the effect of acute administration of vitamin D on micro vascular endothelial function in people with diabetes

  • Petrofsky, Jerrold;Alshammari, Faris;Khowailed, Iman Akef;Lodha, Riya;Deshpande, Pooja;Rajaram, Praveen;Gaikwad, Mahendra;Vadera, Vidhi
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • Objective: To assess the effect of vitamin D administration on the skin blood flow response to occlusion and heat. Design: Cross-sectional study. Methods: Twenty age matched subjects; 10 who had diabetes and 10 who were controls were administered 4,000 IU of vitamin D3 for 3 weeks at breakfast. The function of the endothelial cells was evaluated in 2 ways; first, the response to 4 minutes of vascular occlusion of the skin was measured with a laser Doppler flow meter. Second, the skin blood flow response to local heat at 42 degrees C for 6 minutes was examined. Results: The results of the experiments showed that the blood flow response to heat was reduced after 3 weeks administration of vitamin D in the subjects with diabetes and in the control subjects (p<0.05). The response to occlusion was not significantly different within each group before and after vitamin D administration, but the group with diabetes had a significantly lower blood flow response to occlusion than did the controls (p<0.05). Conclusions: Acute doses of vitamin D may impair nitric oxide production and reduce blood flow to tissue during stressors in people with diabetes.

The effect of coenzyme Q10 on endothelial function in a young population

  • Petrofsky, Jerrold;Laymon, M.;Lee, H.;Hernandez, E.;Dequine, D.;Thorsen, L.;Lovell, R.;Andrade, J.
    • Physical Therapy Rehabilitation Science
    • /
    • v.1 no.1
    • /
    • pp.6-12
    • /
    • 2012
  • Objective: Coenzyme (CoQ10) is an enzymatic co factor used in normal cellular metabolism. Recent evidence shows that in people with heart disease it can reverse endothelial cell damage in the blood vessels. It is also a potent antioxidant. Design: One group pretest-posttest design. Methods: In the present study, endothelial function was evaluated using the response to occlusion and heat before and 2 weeks after administration of CoQ10, 300 mg/day. Thirty Eight subjects, who are physical therapy students, participated in a series of experiments to see if taking 300 mg of CoQ10 daily for 2 weeks would impact resting blood flow in the forearm skin and the blood flow response to 4 minutes of vascular occlusion and the response to local heat ($42^{\circ}C$) for 6 minutes. Results: The results showed that, for this population, there was no difference in the response to heat. However, the response to occlusion was improved after administration of CoQ10. Conclusions: It would appear that in a young population CoQ10 has no effect on the nitric oxide vasodilator pathway in skin but does influence other vasodilator pathways.

  • PDF

Thromboembolectomy in Acute Arterial Occlusion (급성 동맥폐색증에서 혈전색전 제거술 -48례 경험-)

  • 김진희
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.792-797
    • /
    • 2000
  • Background : Even though there were developments in various treatment techniques for acute arterial occlusion this disease still has high rate of mortalities and limb amputations. We investigated the combined diseases symptoms location of occlusion type of treatment complication and prognosis in our patients. Meterial and methods: This study recruited 48 patients(42 men, 6 women, mean age 57.7 years) who received the operation from January 1995 toDecember 1998. We investigated the post-operation course via medical record review or telephone interview with patients or their family members. Result: The most common combined diseases were atherosclerosis in 30 patients. other diseases were 17 diabetes mellitus 16 hypertension and 12 atrial firillation. Pain and clod sensation were noticed in all patients paresthesia in 5 patients fibrillation. Pain and cold sensation were noticed in all patients paresthesia in 5 patients and lower extremity paralysis in 11 patients. In 29 patients the time interval from the onset of symptom to admission was over 72 hours and 15 patients were admitted within 24 hours. The distribution of arterial occlusion location was at 28 femoral arteries 14 popliteal arteries and 6 iliac arteries. All the patients were received embolectomy and 5 patients were received additional bypass grafting. Postoperative complications were 12 reocclusions. 6 compartment syndromes 6 skin necrosis and 2 acute renal failure. The mortality rate was 16.7%(8/48) and the amputation rate was 25% Conclusion : This study revealed 25% reocclusion 25% limb amputation and 16.7% mortaliyt. To improve the prognosis of acute lower extrements arterial occlusion early diagnosis and understand the underlying diseases prompt treatment and operation additional operation including interventional radiologic examination and thorough postoperative care would be appreciated.

  • PDF

Changes in Bypass Flow during Temporary Occlusion of Unused Branch of Superficial Temporal Artery

  • Kim, Joon-Young;Jo, Kwang-Wook;Kim, Young-Woo;Kim, Seong-Rim;Park, Ik-Seong;Baik, Min-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.2
    • /
    • pp.105-108
    • /
    • 2010
  • Objective : Some neurosurgeons intentionally ligate the branches of the superficial temporal artery (STA) that are not used in standard STA-to-middle cerebral artery (MCA) anastomosis for the purpose of improving the flow rate in the bypass graft. We investigated changes in bypass flow during temporary occlusion of such unused branches of the STA. Methods : Bypass blood flow was measured by a quantitative microvascular ultrasonic flow probe before and after temporary occlusion of branches of the STA that were not used for anastomosis. We performed measurements on twelve subjects and statistically assessed changes in flow. We also examined all the patients with digital subtraction angiography in order to observe any post-operative changes in STA diameter. Results : Initial STA flow ranged from 15 mL/min to 85 mL/min, and the flow did not change significantly during occlusion as compared with preocclusion flow. The occlusion time was extended by 30 minutes in all cases, but this did not contribute to any significant flow change. Conclusion : The amount of bypass flow in the STA seems to be influenced not by donor vessel status but by recipient vessel demand. Ligation of the unused STA branch after completion of anastomosis does not contribute to improvement in bypass flow immediately after surgery, and furthermore, carries some risk of skin necrosis. It is better to leave the unused branch of the STA intact for use in secondary operation and to prevent donor vessel occlusion.

Gabor-Features Based Wavelet Decomposition Method for Face Detection (얼굴 검출을 위한 Gabor 특징 기반의 웨이블릿 분해 방법)

  • Lee, Jung-Moon;Choi, Chan-Sok
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.143-148
    • /
    • 2008
  • A real-time face detection is to find human faces robustly under the cluttered background free from the effect of occlusion by other objects or various lightening conditions. We propose a face detection system for real-time applications using wavelet decomposition method based on Gabor features. Firstly, skin candidate regions are extracted from the given image by skin color filtering and projection method. Then Gabor-feature based template matching is performed to choose face cadidate from the skin candidate regions. The chosen face candidate region is transformed into 2-level wavelet decomposition images, from which feature vectors are extracted for classification. Based on the extracted feature vectors, the face candidate region is finally classified into either face or nonface class by the Levenberg-Marguardt back-propagation neural network.

  • PDF

Skin Lesion Image Segmentation Based on Adversarial Networks

  • Wang, Ning;Peng, Yanjun;Wang, Yuanhong;Wang, Meiling
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.6
    • /
    • pp.2826-2840
    • /
    • 2018
  • Traditional methods based active contours or region merging are powerless in processing images with blurring border or hair occlusion. In this paper, a structure based convolutional neural networks is proposed to solve segmentation of skin lesion image. The structure mainly consists of two networks which are segmentation net and discrimination net. The segmentation net is designed based U-net that used to generate the mask of lesion, while the discrimination net is designed with only convolutional layers that used to determine whether input image is from ground truth labels or generated images. Images were obtained from "Skin Lesion Analysis Toward Melanoma Detection" challenge which was hosted by ISBI 2016 conference. We achieved segmentation average accuracy of 0.97, dice coefficient of 0.94 and Jaccard index of 0.89 which outperform the other existed state-of-the-art segmentation networks, including winner of ISBI 2016 challenge for skin melanoma segmentation.

Real-time Face Tracking Method using Improved CamShift (향상된 캠쉬프트를 사용한 실시간 얼굴추적 방법)

  • Lee, Jun-Hwan;Yoo, Jisang
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.861-877
    • /
    • 2016
  • This paper first discusses the disadvantages of the existing CamShift Algorithm for real time face tracking, and then proposes a new Camshift Algorithm that performs better than the existing algorithm. The existing CamShift Algorithm shows unstable tracking when tracing similar colors in the background of objects. This drawback of the existing CamShift is resolved by using Kinect’s pixel-by-pixel depth information and the Skin Detection algorithm to extract candidate skin regions based on HSV color space. Additionally, even when the tracking object is not found, or when occlusion occurs, the feature point-based matching algorithm makes it robust to occlusion. By applying the improved CamShift algorithm to face tracking, the proposed real-time face tracking algorithm can be applied to various fields. The results from the experiment prove that the proposed algorithm is superior in tracking performance to that of existing TLD tracking algorithm, and offers faster processing speed. Also, while the proposed algorithm has a slower processing speed than CamShift, it overcomes all the existing shortfalls of the existing CamShift.