• 제목/요약/키워드: Skin Depth

검색결과 371건 처리시간 0.028초

동심원내에서 진동하는 내부 실린더에 작용하는 유체유발력의 근사적 해법 (An Approximate Analytical Method for Hydrodynamic Forces on Oscillating Inner Cylinder in Concentric Annulus)

  • 심우건
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.861-869
    • /
    • 1997
  • An approximate analytical method has been developed for estimating hydrodynamic forces acting on oscillating inner cylinder in concentric annulus. When the rigid inner cylinder executes translational oscillation, fluid inertia and damping forces on the oscillating cylinder are generated by unsteady pressure and viscous skin friction. Considering the dynamic-characteristics of unsteady viscous flow and the added mass coefficient of inviscid fluid, these hydrodynamic forces including viscous effect are dramatically simplified and expressed in terms of oscillatory Reynolds number and the geometry of annular configuration. Thus, the viscous effect on the forces can be estimated very easily compared to an existing theory. The forces are calculated by two models developed for relatively high and low oscillatory Reynolds numbers. The model for low oscillatory Reynolds number is suitable for relatively high ratio of the penetration depth to annular space while the model for high oscillatory Reynolds number is applicable to the case of relatively low ratio. It is found that the transient ratio between two models is approximately 0.2~0.25 and the forcea are expressed in terms of oscillatory Reynolds number, explicity. The present results show good agreements with an existing numerical results, especially for high and low penetration ratios to annular gap.

  • PDF

고심도 지반환경 조사 - 지반조사 (1) (GEOTECHNICAL ENVIRONMENT SURVEY (1))

  • 손호웅;이대근;김상규
    • 지구물리
    • /
    • 제6권4호
    • /
    • pp.231-244
    • /
    • 2003
  • 지하에는 수많은 각종 시설물이 매설되어 있으며 이러한 지하매설물의 효율적인 관리는 도시의 원활한 운영을 위한 중요과제가 되어가고 있다 지하에 매설된 각종 시설물의 위치 및 깊이를 조사하기 위한 탐사방법으로 GPR탐사 및 유도전류 방법이 거의 전적으로 적용되고 있으나 가탐심도가 매우 낮으며 지하매질이 매우 불균질 하거나 점토 염분 자갈 등이 많은 곳 및 주변의 전자기적 잡음이 심한 곳에서는 조사가 안 되는 경우가 많다 본 연구에서는 광역상수관이 천부 및 심부에 다수 매설되어 있으나 열악한 지반환경 때문에 지하매설물을 탐지할 수 없는 지역에서 효과적으로 탐사할 수 있는 지구물리탐사법을 찾고자 하였으며 다양한 지구물리탐사방법 적용하였으며 그 결과를 비교 분석하였다 한편 연구지역의 열악한 지질환경을 알기 위하여 지반조사를 수행하여 지반환경에 따른 물리탐사의 영향을 알아보고자 하였다

  • PDF

전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰 (A study on dose attenuation in bone density when TBI using diode detector and TLD)

  • 임현실;이정진;장안기;김완선
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.67-77
    • /
    • 2003
  • I. 목적 전신방사선조사(TBI)시 균등한 선량을 조사할 목적으로 사용되는 각 신체부위별 보상체(compensator) 두께의 결정은 열형광선량계(TLD)를 이용하여 표면선량(surface dose)를 측정하고, 심부선량(depth dose)으로 환산하는 방법을 주로 이용한다. 그러나 이와 같은 방법은 골(bone) 조직에 대한 선량감쇄(dose attenuation)의 영향이 고려되지 않아 신체중심부에서의 정확한 심부선량을 알 수가 없다. 이에 본 연구에서는 열형광선량계와 다이오드측정기(Diode detector)로 표면선량과 심부선량을 동시에 측정하여 골조직에서의 선량감쇄 영향을 알아보고자 한다. II. 대상 및 방법 실험은 본원에서 TBI 치료를 받은 5명의 환자를 대상으로 실시하였으며, 측정장비로는 Siemens Mevatron 10MV X-ray, TLD(Harshaw 5500), Diode detector(Sun Nuclear)를 사용하였다. 선량 조사방법은 복부의 배꼽(umblicus)를 중심으로 하여 이문대향법(Bilateral)으로 150cGy가 조사되도록 하였다. 측정방법은 열형광선량계로 두부, 경부, 대퇴부, 슬관절, 족관절, 부위의 표면선량을 측정하였으며, 이 가운데 대퇴부, 슬관절, 족관절에서는 중심부 선량측정이 가능하여 동시에 심부선량을 측정하였다. 또한 실험대상자 중 3명의 환자는 상기와 같은 부위(두부, 경부, 대퇴부, 슬관절, 족관절)에 다이오드측정기로 심부선량을 측정하였다. III. 결과 TLD로 측정한 표면선량을 심부선량으로 환산한 값은 두부, 경부, 대퇴부, 슬관절, 족관절에서 각각 $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ 이었고, 중심부 심부선량 측정이 가능한 대퇴부, 슬관절, 족관절에서는 각각 $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$로 나타났다. 따라서 표면선량과 중심부 심부선량 비교가 가능한 대퇴부, 슬관절, 족관절에서의 TLD의 측정치를 비교해보면 부위에 따라 최소 $6.67\%{\sim}$ 최대 $11.65\%$까지 골조직에 의한 선량감소가 나타나는 것을 알 수가 있다. 또한, Diode detector로 측정한 심부선량 값은 두부, 경부, 대퇴부, 슬관절, 족관절에서 각각 $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$으로 나타났으며, TLD로 측정한 대퇴부, 슬관절, 족관절에서의 표면선량과 비교했을 때 부위에 따라 최소 $4.53\%{\sim}$ 최대 $12.6\%$ 까지 차이를 보였다. 그리고 골조직에 의한 선량감쇄의 영향이 적은 복부(배꼽)에서는 열형광선량계 및 다이로드측정기로 측정한 값이 각각 $101.58{\pm}0.95,\;104.77{\pm}1.18$로 큰 차이가 없었다. IV 결론 전신방사선조사시 표면선량을 측정하여 심부선량으로 환산한 값은 골조직의 감쇄영향을 고려하지 못하므로 다이로드측정기(Diode detector) 또는 열형광선량계(TLD)로 중심부선량을 직접 측정하는 것이 중요하다. 그러나 중심부의 심부선량을 직접 측정할 수 없을 경우에는 골조직의 감쇄영향을 고려하여 복부배꼽에서의 선량보다 $5\%{\sim}10\%$ 정도의 선량이 초과 조사되도록 보상물질의 두께를 적절하게 조절하는 것이 필요할 것으로 사료된다.

  • PDF

다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포 (Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses)

  • Kim, Sookil
    • 한국의학물리학회지:의학물리
    • /
    • 제10권2호
    • /
    • pp.83-88
    • /
    • 1999
  • 목적 : 금속박막과 고체 팬텀이 선량 분포와 선량 측정에 미치는 영향을 연구하기 위하여 TLD 실험을 행하였다. 본 연구의 목적은 주어진 고체 팬텀 환경 내에서 TLD 기판 위에 놓인 금속박막의 build-up 효과와 깊이선량 분포를 알아보고자 하였다. 대상 및 방법 : 측정은 TLD 기판과 같은 면적 (3.2 $\times$ 3.2 $\textrm{mm}^2$)의 금속박막을 LiF TLD-100 위에 얹어서 행하였다. 여러 종류 (주석, 구리, 금) 의 다양한 두께 (0.1, 0.15, 0.2, 0.3 mm)를 가진 금속박막 중에 한 개를 TLD 기판 위에는 얹어서 각 각의 흡수선량을 측정하였다. 금속박막을 얹은 TLD 기판을 사용하여 고체 팬텀에서의 표면홉수선량과 최대 build-up 영역에서 흡수선량을 측정하였다. 결과 : 금속박막을 이용한 TLD 기판의 경우 표면흡수선량이 증가하였고, 물에 대한 금속의 등가 두께에 따른 표면흡수선량 곡선에는 build-up 이 뚜렷이 관측되었다. 최대 build-up 영역에서 관측한 흡수선량 측정값은 금속박막을 없지 않은 TLD의 경우보다 약 8% 에서 13% 정도의 보다 작은 값을 나타내었다. 결론 : TLD 선량 측정 시 금속 박막 법은 깊이에 따른 흡수선량 뿐 만 아니라 피부 표면으로부터 약 4.2mm 깊이까지의 홉수선량의 build-up 에 관련 정보를 의료진에 제공할 수 있으며, 금속박막을 얹은 TLD에 관한 실험 결과는 피부 특정 영역에서의 bolus 의 결정에 도움이 될 것으로 사료됨.

  • PDF

해양혼합층 모델 적용을 통한 고해상도 지역예측모델 성능개선에 대한 연구 (A Study on Improvement of High Resolution Regional NWP by Applying Ocean Mixed Layer Model)

  • 민재식;지준범;장민;박정균
    • 대기
    • /
    • 제27권3호
    • /
    • pp.317-329
    • /
    • 2017
  • Ocean mixed layer (OML) depth affects diurnal cycle of sea surface temperature (SST) induced by change of solar radiation absorption and heat budget in ocean. The diurnal SST variation can lead to convection over the ocean, which can impact on localized precipitation both over coastal and inland. In this study, we investigate the OML characteristics affecting the diurnal cycle of SST for the Korean Peninsula and surrounding areas. To analyze OML characteristics, HYCOM oceanic mixed layer depth (MLD) and wind field at 10 m from ERA-interim during 2008~2016 are used. In the winter, MLD is deeply formed when the strong wind field is located on perpendicular to continental slope over deep seafloor areas. Besides, cooling SST-induced vertical mixing in OML is reinforced by dry cold air originated from Siberia. The OML in summer is shallowly distributed about 20 m. In order to estimate the impact of OML model in high resolution NWP model, four experimental simulations are performed. At this time, the prognostic scheme of skin SST is applied in NWP to simulate diurnal SST. The simulation results show that CNTL (off-OML) overestimates diurnal cycle of SST, while EXPs (on-OML) indicate similar results to observations. The prediction performance for precipitation of EXPs shows improvement compared with CNTL over coastal as well as inland. This results suggest that the application of the OML model in summer season can contribute to improving the prediction for performance of SST and precipitation over coastal area and inland.

무작위 대조 시험을 통한 족관절 염좌의 자침 중 심자와 천자의 비교 연구-준비 조사 (Comparison of Superficial and Deep Acupuncture in the Treatment of Ankle sprain : A Randomized Controlled Trial-Pilot study)

  • 박준성;김우영;백승태;이승덕;김갑성
    • Journal of Acupuncture Research
    • /
    • 제21권5호
    • /
    • pp.137-147
    • /
    • 2004
  • Objective : The aim of the study was to compare the therapeutic effect of the superficial and in-depth insertion of acupuncture needles in the treatment of patients with ankle sprain. Design : A prospective randomized single-blind study of superficial and deep acupuncture was conducted. Setting : The study was conducted in the Kang-nam Oriental Hosp. of Dong-Guk University. Patients: The study comprised 14 patients with ankle sprain who were divided into two groups (A and B). Intervention : In group A, the needle was introduced in the skin at a depth of 2 mm, whereas in group B the needle was placed deeply into muscular tissue or the articular capsule at a depth more than 1.5 Cm The treatment was planned for a duration of 1 week, 3 times. Outcome Measures : The intensity of pain was evaluated with the Ankle grade pain chart(AGPC) before and after treatment and at the 1-week follow-up examination. The AGPC includes Swelling, Tenderness, Exudation, Bruise, Medial/Lateral. stability test, Anterior drawer test, Squeeze test, Bearing weight, Pressure Algometer, Walking state and VAS. Results : Although at the end of the treatment there was no evidence of significant statistical differences between the two different groups, Pain reduction(VAS) was greater in the group treated with deep acupuncture. A statistical difference existed between the two groups at the 1 week follow up, with a better result in the deeply stimulated group in VAS. Conclusion : Clinical results show that deep stimulation has a better analgesic effect when compared with superficial stimulation in pain reduction(VAS, Visual analogic scale).

  • PDF

연령 확산 이론에 의한 전자선의 조직내 선량분포 평가 (Evaluation of Electron Beam Dose Distribution by Age Diffusion Equation)

  • 추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제4권1호
    • /
    • pp.29-39
    • /
    • 1993
  • 고에너지 전자선은 방사선치료에서 중요한 역할을 담당하고 있으나 전하를 갖인 입자로서 인체조직과 상호작용이 복잡하여 조직내 전자선량분포를 정확히 표현하기에는 매우 어렵다. 전자선분포를 계산하는 데는 심부율과 평면분포율등 여러방법이 제시되고 있었으나 수학적 모형을 이용하는 것이 가장 신속하고 다양한 계산을 수행할수 있는 수단으로 알려져 왔으며 컴퓨터의 발달과 병행하여 실요화 되고 있다. 저자들은 연령확산방정식을 기초로한 수식적 모델을 도입하고 연세암센터에 설치된 선형가속기에서 측정된 전자선의 분포를 이용하여 실험식의 상수인자를 결정 삽입하므로서 조직내 어떤 깊이 어느 지점에서도 정확한 선량이 계산될 수 있는 실험식을 완성하였다. 사용자는 연령확산 실험식에서 전자선의 에너지와 조사면 그리고 선원간의 거리만 입력하면 조직내 전자선의 심부율과 등선량곡선을 정확히 예측할 수가 있고 고선량부위에서는 위축되고 저선량부위에서는 확산되는 등선량곡선의 모양을 정확히 기술할 수 있으며 컴퓨터에 의한 선량계획은 어떤 입상상태에서도 간단하고 신속하게 표시할 수 있었다. 전자선의 에너지 6-20MeV 에서 심부율의 정확도는 섬부율 50%이상일 때는 2% 이내이며 낮은 심부율 부위에서는 5%의 오차를 가졌고 조사면 6$\times$6$cm^2$에서 25$\times$25$cm^2$에 대한 심부율 오차는 3% 이내이며 확산오차는 3mm 이하로서 정확성이 비교적 높았다.

  • PDF

다엽 콜리메이터와 제작차폐물의 동시 사용시 표면선량 변화 (Surface and Percentage Depth Doses for Multileaf Collimator Conjunction with Conventional Block)

  • 양광모;서현숙
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.62-68
    • /
    • 2002
  • 최근 설치된 선형가속기는 다엽 콜리메이터를 장착하고 있다. 기본적으로 다엽 콜리메이트의 사용은 기존의 차폐블럭을 대체하는 역할을 한다. 그러나 다엽 콜리메이터는 폭 1 cm의 콜리메이터가 각각 움직여서 방사선 조사 범위를 만들어 정교한 조사범위를 만들기 어려운 경우가 있을 수 있다. 따라서 조사야를 보다 정밀하게 만들기 위해 다엽 콜리메이터 아래 추가 차폐물을 사용하게 된다. 다엽 콜리메이터 아래 추가 차폐물을 사용할 경우 차폐물과 환자의 피부표면과의 거리가 짧아져 피부표면 선량이 증가하게 되며 최대 선량점(D$_{max}$)이 변할 수 있다. 이와 같은 변화는 조사야의 크기와 방사선의 에너지에 따라 영향을 받을 수 있다. 따라서 본 연구는 다엽 콜리메이터 아래 추가 차폐물을 사용할 때 조사야와 방사선에너지에 따라 표면선량과 최대 선량점의 변화를 측정하여 이들 값이 증가함을 확인하였고 다엽 콜리메이터 아래 추가 차폐물을 사용함으로써 증가한 표면선량은 전자 흡수판으로 2-3 mm 두께의 납판을 사용하여 효과적으로 감소시킬 수 있음을 확인하였다.

  • PDF

바이코히어런스 분석 기법을 이용한 마취 단계별 뇌파의 특성 분석 (EEG Signal Characteristic Analysis for Monitoring of Anesthesia Depth Using Bicoherence Analysis Method)

  • 박준모;박종덕;전계록;허영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권1호
    • /
    • pp.35-41
    • /
    • 2006
  • Although reachers have studied for a long time, they don't make criteria for anesthesia depth. anesthetists can't make a prediction about patient's reaction. Therefor, patients have potential risk such as poisonous side effect late-awake, early-awake and strain reaction. EEG are received from twenty-five patients who agreed to investigate themselves during operation with Enflurane-anesthesis in progress of anesthesia. EEG are divided pre-anesthesia, before incision of skin, operation 1, operation 2, awaking, post-anesthesia by anesthesia progress step. EEG is applied pre-processing, base line correct, linear detrend to get more reliable data. EEG data are handled by electronic processing and the EEG data are calculated by bicoherence. During pre-anesthesia and post anesthesia, appearance rate of bicoherence value is observed strong appearance rate in high frequency range($15\~30Hz$). During the anesthesia of patient, a strong appearance rate is revealed the low frequency area(0~10Hz). After bicoherence is calculated by percentage of a appearance rate, that is, Bicpara$\#$1, Bicpara$\#$2, Bicpara$\#$3 and Bicpara$\#$4 parameter are extracted. In result of bicoherence analysis, Bicpara$\#$2 and Bicpara#4 are considered that the best parameter showed progress of anesthesia effectively. And each separated bicoherence are calculated by average bicoherence's numerical value, divide by 2 area, appear by each BicHz$\#$1, BicHz$\#$2, and observed BicHz$\#$1/BicHz$\#$2's change. In result of bicoherence analysis, BicHz$\#$1, BicHz$\#$2 and BicHz$\#$1/BicHz$\#$2 are considered that the best parameter showed progress of anesthesia effectively. In conclusion, I confirmed the anesthesia progress phase, concluded to usefulness of parameter on bispectrum and bicoherence analysis and evaluated the depth of anesthesia. In the future, it is going to use for doctor's diagnosis and apply to protect an medical accident owing to anesthesia.

밤의 화염박피 시스템 최적화에 관한 연구(I) - 국내산 밤의 화염박피 특성 예측모델 개발 - (Study on Optimization of Flame Peeling System for Chestnut(I) - Development of Simulation Model for Flame Peeling Characteristics -)

  • 김종훈;박재복;최창현;권기현
    • Journal of Biosystems Engineering
    • /
    • 제29권1호
    • /
    • pp.45-52
    • /
    • 2004
  • The chestnut is a well-blown and important forest product in Korea. The annual production of chestnut is about 95,000 tons and its cultivating area is 80,000 ha. However, the peeling process of outer and inner skins of chestnut is very difficult due to hardness and adhesiveness of chestnut skin. The purpose of this study was to develop a prediction model for flame peeling characteristics of domestic chestnuts, and to evaluate an optimization model to determine the operation conditions of the chestnut flame peeling system. The results of this study were summarized as follows. It was found that the flame peeling characteristics of domestic chestnuts were by the flame temperature, and the flame time. The peeling ratio and the heating depth were increased as the flame temperature and the flame time were increased. The peeling ratio and the heating depth were increased linearly when those were less than 85 % and 2 mm respectively. As the hardness of chestnut shell was decreased, the peeling ratio was increased. A simulation model was developed to predict the peeling ratio and the heating depth based on the hardness of the chestnut shell, the flame temperature, and the flame time of the peeling system. The model was evaluated by comparing the measurement and the prediction of the peeling ratios and heating depths, and showed the good relationship.