• Title/Summary/Keyword: Skin Depth

Search Result 373, Processing Time 0.028 seconds

A Comparison of the Propagation and Noise Characteristics between Ultrasonic and Electromagnetic Wave for the High Speed Communication of Short Range Telemetry (단거리 텔레메트리용 고속통신을 위한 전자기파 및 초음파의 전파 및 잡음 특성 분석)

  • Choi, Chang-Hyo;Seo, Gang-Do;Park, Hee-Jun;Park, Il-Yong;Cho, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.68-71
    • /
    • 2001
  • This paper has been studied for a comparison of the propagation and noise characteristics between ultrasonic and electromagnetic wave for the high speed communication of the short range telemetry. We analyze the propagation depth of electromagnetic and ultrasonic wave by skin depth effect and by ultrasonic loss ratio. We also studied several effects such as near field effect in electromagnetic wave and Rayleigh scattering noise of ultrasonic wave, etc. We show the experimental results of their propagation loss and modulation experiments in water. The experimental results show that both method is good for the implementation of short range telemetry.

  • PDF

An Approximate Analytical Method for Hydrodynamic Forces on Oscillating Inner Cylinder in Concentric Annulus (동심원내에서 진동하는 내부 실린더에 작용하는 유체유발력의 근사적 해법)

  • 심우건
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.861-869
    • /
    • 1997
  • An approximate analytical method has been developed for estimating hydrodynamic forces acting on oscillating inner cylinder in concentric annulus. When the rigid inner cylinder executes translational oscillation, fluid inertia and damping forces on the oscillating cylinder are generated by unsteady pressure and viscous skin friction. Considering the dynamic-characteristics of unsteady viscous flow and the added mass coefficient of inviscid fluid, these hydrodynamic forces including viscous effect are dramatically simplified and expressed in terms of oscillatory Reynolds number and the geometry of annular configuration. Thus, the viscous effect on the forces can be estimated very easily compared to an existing theory. The forces are calculated by two models developed for relatively high and low oscillatory Reynolds numbers. The model for low oscillatory Reynolds number is suitable for relatively high ratio of the penetration depth to annular space while the model for high oscillatory Reynolds number is applicable to the case of relatively low ratio. It is found that the transient ratio between two models is approximately 0.2~0.25 and the forcea are expressed in terms of oscillatory Reynolds number, explicity. The present results show good agreements with an existing numerical results, especially for high and low penetration ratios to annular gap.

  • PDF

GEOTECHNICAL ENVIRONMENT SURVEY (1) (고심도 지반환경 조사 - 지반조사 (1))

  • HoWoongShon;DaeKeunLee;SangKyuKim
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.4
    • /
    • pp.231-244
    • /
    • 2003
  • Lots of various utilities are buried under the surface of the earth. The effective handling of the underground utilities is becoming the big subject and project for the harmonious management and administration of the city. To detect the position and depth of buried underground utilities, GPR and Induced EM surveys are commonly used. However, they have limitations, such as shallow skin-depth and non-availability in the areas where subsurface materials are not homogeneous and are compose of clays and/or salts and gravels. The aim of this study is to find the efficient geophysical method which can overcome these limitations. For this purpose, various geophysical mehods were applied in the site of poor geotechnical environment.

  • PDF

Foundation Color Image Analysis (파운데이션 색상 이미지 분석)

  • Hee-Kyung Lim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.1580-1588
    • /
    • 2023
  • The desire for clear and clean skin is universal among both men and women. Women, in particular, seek the help of foundation to achieve beautiful and transparent skin. The choice of foundation is not determined by the race of an individual; instead, it varies based on personal skin color and undertone. Therefore, there is a need to surpass the stereotype of using foundation colors based on racial discrimination. The purpose of this study is to randomly select cosmetics brands from Korea, China, Japan, the United States, France, and the United Kingdom, considering the impact of each photo, environment, and equipment. The objective is to understand the differences in skin tones in foundation advertisement model images on websites. Analyzing the RGB values of foundation colors for each brand revealed that in Korea, the colors were 8.75R, 1.25YR, 2.5YR, 3.75YR, 5YR, and 6.25YR. Chinese brands showed similar colors with 2.5YR, 3.75YR, 5YR, 6.25YR, and 10YR. Japanese brands displayed colors such as 7.5R, 8.75R, 10R, 5YR, 6.25YR, and 7.5YR. American brands presented colors like 6.25R, 8.75R, 10R, 2.5YR, 3.75YR, 5YR, 6.25YR, 7.5YR, and 10YR. French brands featured 10R, 1.25YR, 3.75YR, 5YR. Lastly, British brands displayed 2.5YR, 3.75YR, 7.5YR. As a follow-up study, in-depth research on the reshaping and color changes of foundation over time is recommended. It is hoped that this research will serve as fundamental data for makeup companies' marketing and contribute to the development of both domestic and international color cosmetics markets.

A study on dose attenuation in bone density when TBI using diode detector and TLD (전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰)

  • IM Hyun Sil;Lee Jung Jin;Jang Ahn Ki;Kim Wan Seon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • I. Purpose Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. II. Materials and Methods The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. III. Results Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ respectably. Measured mid-depth dose of pelvis, knees and ankles were $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$ respectably. There were $6.67\%{\sim}11.65\%$ dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$ respectably. There were $4.53\%{\sim}12.6\%$ dose attenuation at mid-depth in pelvis, knees and ankles. IV. Conclusion We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  • PDF

Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses (다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포)

  • Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.83-88
    • /
    • 1999
  • Purpose: TLD experiments were set up to measure the dose distribution and to analyze the influence on dose measurement of thin metal plate and solid water phantom. The aim of the present study was to investigate the build-up effect of metal plate loaded on TLD chip and depth dose in the controlled environment of phantom measurements. Materials and Methods: Measurements were done by using LiF TLD-100 loaded by a thin metal plate with the same surface area (3.2$\times$3.2 $\textrm{mm}^2$) as TLD chip. TLD chips loaded with one metal plate from three different metal plate (Tin, Copper, Gold) of different thicknesses (0.1, 0.15, 0.2, 0.3 mm) were used respectively to measure radiation dose. Using the TLD loaded with one metal plate, surface dose and the depth dose at the build-up maximum region were investigated. Results: Using a metal plate on TLD chip increased the surface dose. Surface dose curve shows the dose build-up against equivalent thickness of metal to water. The values of TL reading obtained by using metal plate at depth of build-up maximum are about 8% to 13% lower than those obtained by normal TLD chip. Conclusion: The metal technique used for TLD dosimetry could provide clinicals information about the build-up of dose up to 4.2mm depth in addition to a depth dose distribution. The results of TLD with a metal plate measurements may help with decisions to boost or bolus certain areas of the skin.

  • PDF

A Study on Improvement of High Resolution Regional NWP by Applying Ocean Mixed Layer Model (해양혼합층 모델 적용을 통한 고해상도 지역예측모델 성능개선에 대한 연구)

  • Min, Jae-Sik;Jee, Joon-Bum;Jang, Min;Park, Jeong-Gyun
    • Atmosphere
    • /
    • v.27 no.3
    • /
    • pp.317-329
    • /
    • 2017
  • Ocean mixed layer (OML) depth affects diurnal cycle of sea surface temperature (SST) induced by change of solar radiation absorption and heat budget in ocean. The diurnal SST variation can lead to convection over the ocean, which can impact on localized precipitation both over coastal and inland. In this study, we investigate the OML characteristics affecting the diurnal cycle of SST for the Korean Peninsula and surrounding areas. To analyze OML characteristics, HYCOM oceanic mixed layer depth (MLD) and wind field at 10 m from ERA-interim during 2008~2016 are used. In the winter, MLD is deeply formed when the strong wind field is located on perpendicular to continental slope over deep seafloor areas. Besides, cooling SST-induced vertical mixing in OML is reinforced by dry cold air originated from Siberia. The OML in summer is shallowly distributed about 20 m. In order to estimate the impact of OML model in high resolution NWP model, four experimental simulations are performed. At this time, the prognostic scheme of skin SST is applied in NWP to simulate diurnal SST. The simulation results show that CNTL (off-OML) overestimates diurnal cycle of SST, while EXPs (on-OML) indicate similar results to observations. The prediction performance for precipitation of EXPs shows improvement compared with CNTL over coastal as well as inland. This results suggest that the application of the OML model in summer season can contribute to improving the prediction for performance of SST and precipitation over coastal area and inland.

Comparison of Superficial and Deep Acupuncture in the Treatment of Ankle sprain : A Randomized Controlled Trial-Pilot study (무작위 대조 시험을 통한 족관절 염좌의 자침 중 심자와 천자의 비교 연구-준비 조사)

  • Park, Jun-sung;Kim, Woo-young;Baek, Seung-tae;Lee, Seung-deok;Kim, Kap-sung
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.137-147
    • /
    • 2004
  • Objective : The aim of the study was to compare the therapeutic effect of the superficial and in-depth insertion of acupuncture needles in the treatment of patients with ankle sprain. Design : A prospective randomized single-blind study of superficial and deep acupuncture was conducted. Setting : The study was conducted in the Kang-nam Oriental Hosp. of Dong-Guk University. Patients: The study comprised 14 patients with ankle sprain who were divided into two groups (A and B). Intervention : In group A, the needle was introduced in the skin at a depth of 2 mm, whereas in group B the needle was placed deeply into muscular tissue or the articular capsule at a depth more than 1.5 Cm The treatment was planned for a duration of 1 week, 3 times. Outcome Measures : The intensity of pain was evaluated with the Ankle grade pain chart(AGPC) before and after treatment and at the 1-week follow-up examination. The AGPC includes Swelling, Tenderness, Exudation, Bruise, Medial/Lateral. stability test, Anterior drawer test, Squeeze test, Bearing weight, Pressure Algometer, Walking state and VAS. Results : Although at the end of the treatment there was no evidence of significant statistical differences between the two different groups, Pain reduction(VAS) was greater in the group treated with deep acupuncture. A statistical difference existed between the two groups at the 1 week follow up, with a better result in the deeply stimulated group in VAS. Conclusion : Clinical results show that deep stimulation has a better analgesic effect when compared with superficial stimulation in pain reduction(VAS, Visual analogic scale).

  • PDF

Evaluation of Electron Beam Dose Distribution by Age Diffusion Equation (연령 확산 이론에 의한 전자선의 조직내 선량분포 평가)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.4 no.1
    • /
    • pp.29-39
    • /
    • 1993
  • Electron beams have found unique and complementary used in the treatment of cancer, but it's very difficult to delineate dose distribution, because of multi-collisions. Numerical solution is more usefull to describe electron distributed in tissue. A semi-empirical eqution is given for the dose at any point at various depths in water. This equation is a modificated model which was based on solutions of a general age diffusion equation. Parameters have been calulated from electron beams data with energies 6~18MeV form a LINAC for use in computerised dosimetry calculations. The depth doses and isodose curves are predicted as a function of the practical range, source skin distance and field size. Depth dose accuracy have been achieved 2% above 50% depth dose and 5% at lower doses, relative to maximum dose. Also, the shape of the isodose curves with the constrictions at higher dose and bulging ot lower values are accurately predicted. Computer calculated beams have been used to generate ever isodose distribution for certain clinical situations.

  • PDF

Surface and Percentage Depth Doses for Multileaf Collimator Conjunction with Conventional Block (다엽 콜리메이터와 제작차폐물의 동시 사용시 표면선량 변화)

  • 양광모;서현숙
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.62-68
    • /
    • 2002
  • A muiltileaf collimator (MLC) is used as a replacement for conventional blocks. The MLC, however may not be appropriate for a fine field shaping. For the fine field shaping, conventional block can be added under the MLC. But it may significantly affect on the dosimetric characteristics such as surface dose of skin, buildup region and percent depth doses. We performed the study to evaluate the surface dose and the maximum depth dose using MLC conjunction with conventional blocks for various field sizes and energies. We confirmed the surface dose was increased by using the additional conventional block under the MLC ranging from 10 to 35.6% according to various field sizes and radiation beam energies. The surface dose was effectively reduced by application of 2 or 3 m thickness of lead plate as electron filter.

  • PDF