• Title/Summary/Keyword: Skin Depth

Search Result 371, Processing Time 0.03 seconds

Literature Study for Categorizing Physical Properties of Face, Pulse, Skin and Voice Based on Health State of Sasang Constitutions (사상체질별 건강수준에 따른 맥상, 안면, 피부, 음성의 물리량 도출을 위한 문헌고찰연구)

  • Lee, Jae-Chul;Lee, Yu-Jeong;Kim, Ja-Euk;Kim, Sang-Kil;Kang, Nam-Sik;Kim, Jong-Yeol;Kim, Sang-Hyuk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.755-758
    • /
    • 2011
  • Sasang Constitutional Medicine (SCM) suggests the concept of health condition which is owned of different properties by each Sasang Constitution. But SCM theory has concentrate to explaining different symptoms that distinguish health condition, not much concerned with practical methods like face features, pulse diagnosis, skin surface properties and voice features. Physical properties of practical diagnosis methods from literature finding have been researched. As a result, complexion and face moisture were described to be physical properties related to health State. In scope of pulse diagnosis, depth, rate, contour, width and pressure are related. Skin surfaces' elasticity, moisture, fraction properties were also suggested as factors of health State of Sasang Constitution. We assume that this study would contribute further studies for objectifying and quantifying diagnosis methods to evaluate health state grades of Sasang Constitution.

Development of Non-contact Image Measuring Technique for Evaluating Micro-relief (미세주름 측정을 위한 비접촉식 영상측정기술의 발전)

  • Kim, Nam-Soo;Kim, Yong-Min
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.253-257
    • /
    • 2005
  • Assurance of the objectivity and reproducibility is a major key point in wrinkle measurement used for evaluating the degree of skin aging. The measurement of relief is quickly converted to a non-contact method, of which tools or instruments do not come in contact with skin directly, to minimize the artificial effects which influence the shape or depth of the relief. Here, we showed how wrinkle measurement techniques have been changed briefly and compared PRIMOS and replica method in the point of view of measurement principle and features, the former is non-contact fringe projection tool and the latter is contact type of the method.

Literatural Study on Prescription of the Skin Disease from the Viewpoint of the Onbyung(溫病) (온병적(溫病的) 관점(觀點)으로 본 피부질환(皮膚疾患) 처방(處方)에 관(關)한 고찰(考察))

  • Chang, Seung-Soon;Kang, Jung-Soo
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.113-120
    • /
    • 2000
  • This study was carried out to investigate the relation between the Onbyung and the skin disease, and classify the medical treatment by some categories. The results were as follows ; 1. Onbyung reduces the Eun(陰) by the fever and the skin disease results from the deficiency of the Eun and blood. 2. We can grasp the depth of the disease and the damage of the Jung Gi(正氣) by the observation of the every condition on the skin disease. 3. Medical treatment 1. Hae Phyo Bub(解表法) Using the method of the perspiration, we take care of the preservation of the sap. 2. Cheong Gi Bub(淸氣法) of the using Gypsum and Tong Ha Bub(通下法) of the using Dae Whang(大黃). A. Cheong Gi Bub(淸氣法) When the Sa(邪) stay the Gi area(氣分), we use the radiational material or the Wha Sub(化濕) material with Gypsum. B. Tong Ha Bub(通下法) We reduce the evil fever by the Ha Bub(下法). 3. Cheong Yul Hae Dog Bub(淸熱解毒法) and Ja Eum Bub(滋陰法) 4. Wha Sub Bub(化濕法) This treatment reduce the fever by eliminating the urine or the sweat.

  • PDF

Effect on Wond Healing of Low Power Generating Laser Irradiation on Artificially Produced Wounds of Rabbits (저출력 레이저광선이 가토의 손상치유에 미치는 영향)

  • Young-Jin Park;Choung-Youl Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.73-91
    • /
    • 1994
  • The author used rabbits in order to examine the effect of Ga-As low power generating semiconductor laser on artificially produced injuries of experimental animals. Artificially produced injuries include surgical wound of 3mm length, 2mm depth in size on ventral skin surface of rabbit and buccal mucosa, and electrical injury formed on opposite side of skin and buccal mucosa by electrical cauterization of same length and depth, and chemical injury formed by FC(Formocresol) solution applied on the anterior dorsal part of tongue. And then, on the experimental group, Ga-As laser was irradiated beginning on the day after the wound formation and continued to irradiate every each other day for five minutes. After1, 3, 6, 9, 13th day, certain number of animals of control and experimental group were sacrified, and wound site tissue was excised to make samples and was observed under light microscope. The following is the conclusions after comparing the healing procedure of experimental and control group. The following results were obtained : 1. Inflammation was decreased more rapidly in the experimental group than the control group. 2. In the surgical, the electrical and the chemical injuries in the oral mucosa, re-epithelialization was completed more rapidly in the experimental group than the control group. In the electrical injury on the skin, re-epithelialization was completed about 6 days after wound formation on both groups. 3. In the electrical and the surgical injuries on the oral mucosa, granulation tissue formation started at 3 days after injury on both groups, but in the chemical injury, it was completed about 3 days faster in the control group than the experimental group. In the surgical wound on the skin, it was completed about 9 days after injury, but faster in the experimental group. In the electrical injury on the skin, it was faster in the control group than the experimental group. 4. In the electrical and the surgical injuries on the oral mucosa, fibrosis was started at 6~9 days after injury on both groups, but regeneration of connective tissue in the experimental group was observed much more than the control group. 5. When comparing the effect of wound healing on skin and oral mucosa of control and experimental group, granulation tissue formation and re-epithelialization in the oral mucosa was more vigorous. In conclusion, the difference of timing and the sequence of wound healing process(inflammation, re-epithelialization, granulation tissue formation, fibrosis) following Laser irradiation between control and experimental group was not observed, but the healing tissue was observed much more in the Laser irradiated group.

  • PDF

Beneficial effect of collagen hydrolysate containing collagen tripeptides on ultraviolet B-induced skin photoaging (콜라겐 트리펩타이드를 함유한 콜라겐 가수분해물의 피부 광노화 예방 효과)

  • Kim, Ae-Hyang;Ha, Min Woo;Kim, Jun Il;Piao, Zhe;Shin, Yong Chul;Shin, Daekeun
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.466-472
    • /
    • 2019
  • This study was conducted to investigate anti-photoaging effects of collagen hydrolysate containing collagen tripeptides (CTP) in both HaCaT cells and SKH-1 hairless mice. CTP treatment was nontoxic to HaCaT cells and improved expression of biomarkers associated with aging of skin, such as, collagen 1A, metalloproteinase (MMP)-1, and MMP-13 after subjecting mice to ultraviolet B (UVB) irradiation. In animal studies, the depth and width of wrinkles in the skin of mice were determined upon subjecting them to UVB irradiation. However, positive effects on wrinkles on the skin of mice were seen following CTP supplementation. Collagen content and density of mouse skin were restored following CTP supplementation for 14 weeks after UVB irradiation. These results were based on the effects of CTP on protein levels of collagen 1A, MMP-1, and MMP-13. Therefore, CTP might have positive effects on the number, depth, and width of wrinkles caused by UVB irradiation in SKH-1 hairless mice.

Needling Depth of Cheonchu(ST25) with Computed Tomography: a Retrospective Study (Computed Tomography를 통한 천추(ST25)의 자침 깊이에 대한 후향적 연구)

  • Park, Hae In;Yang, Hyun Jung;Park, Sang Kyun;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.61-67
    • /
    • 2015
  • Objectives : The aim of this study is to investigate the safe needling depth of Cheonchu($ST_{25}$) retrospectively by using an abdomen abdomen computed tomography(CT), and to analyze the correlation between needling depth and the characteristics of the subjects. Methods : We marked spots 50 mm away from both sides of the umbilicus in the abdomen CT and measured the vertical distance to the parietal peritoneum from the skin surface as well as waist circumference. Correlations between measured depth of Cheonchu($ST_{25}$) and variables such as age, gender and waist circumference were analyzed. Results : Average depth of the Cheonchu(n = 90) was $3.21{\pm}0.87cm$, the minimum was 1.31 cm and the maximum was 5.63 cm. A definite positive correlation was noted between needling depth and waist circumference and a significant difference was observed in needling depth according to waist circumference groups. Conclusions : Needling depth of Cheonchu($ST_{25}$) varied depending on the patient's waist circumference; safe needling depth of Cheonchu($ST_{25}$) measured by abdomen CT is 1.31~5.63 cm.

Oceanic Skin-Bulk Temperature Difference through the Comparison of Satellite-Observed Sea Surface Temperature and In-Situ Measurements (인공위성관측 해수면온도와 현장관측 수온의 비교를 통해 본 해양 피층-표층 수온의 차이)

  • Park, Kyung-Ae;Sakaida, Futoki;Kawamura, Hiroshi
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.273-287
    • /
    • 2008
  • Characteristics of skin-bulk sea surface temperature (SST) differences in the Northeast Asia seas were analyzed by utilizing 845 collocated matchup data between NOAA/AVHRR data and oceanic in-situ temperature measurements for selected months from 1994 to 2003. In order to understand diurnal variation of SST within a few meters of the upper ocean, the matchup database were classified into four categories according to day-night and drifter-shipboard measurements. Temperature measurements from daytime drifters showed a good agreement with satellite MCSST (Multi-Channel Sea Surface Temperature) with an RMS error of about $0.56^{\circ}C$. Poor accuracy of SST with an rrns error of $1.12^{\circ}C$ was found in the case of daytime shipboard CTD (Conductivity, Temperature, Depth) measurements. SST differences between MCSST and in-situ measurements are caused by various errors coming from atmospheric moist effect, coastal effect, and others. Most of the remarkable errors were resulted from the diurnal variation of vertical temperature structure within a few meters as well as in-situ oceanic temperatures at different depth, about 20 cm for a satellite-tracked drifting buoy and a few meters for shipboard CTD or moored buoy. This study suggests that satellite-derived SST shows significant errors of about ${\pm}3^{\circ}C$ in some cases and therefore it should be carefully used for one's purpose on the base of in-depth understanding of skin-bulk SST difference and vertical temperature structure in regional sea.

Cavity as a New Passive Device for Reduction of Skin Friction and Heat Transfer (새로운 수동제어소자인 공동을 이용한 마찰력과 열전달 감소에 관한 연구)

  • Hahn Seonghyeon;Choi Haecheon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.463-466
    • /
    • 2002
  • In order to examine the possibility of using a cavity as a passive device for reduction of skin friction and heat transfer, an intensive parametric study over a broad range of the cavity depth and length at different Reynolds numbers is performed for both laminar and turbulent boundary layers in the present study. Direct and large eddy simulation techniques are used for turbulent boundary layers at low and moderate Reynolds numbers, respectively. for both laminar and turbulent boundary layers over a cavity, a flow oscillation occurs due to the shear layer instability when the cavity depth and length are sufficiently large and it plays an important role in the determination of drag and heat-transfer increase or decrease. For a cavity sufficiently small to suppress the flow oscillation, both the total drag and heat transfer are reduced. Therefore, the applicability of a cavity as a passive device for reduction of drag and heat transfer is fully confirmed in the present study. Scaling based on the wall shear rate of the incoming boundary layer is also proposed and it is found to be valid in steady flow over a cavity.

  • PDF

Laser Energy Optimization for Dissimilar Polymer Joining (이종폴리머 접합을 위한 레이저 에너지 최적제어 기법)

  • Song, Chi Hun;Choi, Hae Woon
    • Journal of Welding and Joining
    • /
    • v.32 no.2
    • /
    • pp.63-69
    • /
    • 2014
  • Dual laser heat sources were used for polymer based material joining. An infrared camera and thermocouple DAQ system were used to correlate the temperature distribution to computer simulation. A 50 degree tilted pre-heating laser source was acting as a heating source to promote the temperature to minimize thermal shock by the following a welding heat source. Based on the experimental result, the skin depth was empirically estimated for computer simulation. The offsets of 3mm, 5mm and 10mm split by weld and preheat were effectively used to control the temperature distribution for the optimal laser joining process. The closer offset resulted in an excessive melting or burning caused by sudden temperature rising. The laser power was split by 50%, 75% and 100% of the weld power, and the best results were found at 50% of preheating. To accurately simulate the physical laser beam absorption and joining optical properties were experimentally measured for the computer FEM simulation. The simulation results showed close correlation between theoretical and experimental results. The developed dual laser process is expected to increase productivity and minimize the cost for the final products.

Current Distribution and Effective Resistance in the Rail of a Distributed-type Railgun (분포형 레일건 레일에서의 전류분포 및 실효저항)

  • 임달호;구태만
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.10
    • /
    • pp.694-701
    • /
    • 1988
  • Distributed-type railguns are designed to maintain the armature current and the length between the armature and the current-feed region nearly constant with time. This paper deals with factors affecting current distribution, effective resistance and effective skin depth in the rail of a distributed-type railgun. Analytical solutions for the current distributions and resistance in the rail are presented for a simple two-dimensional model under steady-state contions. For diffusion limited current, it is found that effective rail resistance is proportional to the square root of the relative velocity, the permeability of the rail and the length between the armature and that effective skin depth of the rail is proportional to the square root of the length and inversely proportional to the square root of the permeability, the conductivity and the velocity.