• Title/Summary/Keyword: Sink Unit

Search Result 60, Processing Time 0.025 seconds

MHP: Master-Handoff Protocol for Fast and Energy-Efficient Data Transfer over SPI in Wireless Sensing Systems

  • Yoo, Seung-Mok;Chou, Pai H.
    • ETRI Journal
    • /
    • v.34 no.4
    • /
    • pp.553-563
    • /
    • 2012
  • Serial peripheral interface (SPI) has been identified as a bottleneck in many wireless sensing systems today. SPI is used almost universally as the physical connection between the microcontroller unit (MCU) and radios, storage devices, and many types of sensors. Virtually all wireless sensor nodes today perform up to twice as many bus transactions as necessary to transfer a given piece of data, as an MCU must serve as the bus master in all transactions. To eliminate this bottleneck, we propose the master-handoff protocol. After the MCU initiates reading from the source slave device and writing to the sink slave device, the MCU as a master becomes a slave, and either the source or the sink slave becomes the temporary master. Experiment results show that this master-handoff technique not only cuts the data transfer time in half, but, more importantly, also enables a superlinear energy reduction.

Unit Loads of Pollutants in a Paddy Fields Area with Large-Scaled Plots during Irrigation Seasons (관개기 대구획 광역논에서의 오염부하 원단위)

  • 오승영;김진수;김규성;김선종;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.136-147
    • /
    • 2002
  • Characteristics of unit loads of pollutants were investigated at a paddy fields area(Soro-ri) with large-scaled plots on loam soil during irrigation seasons of 1999 ∼2000. The average irrigation requirement of experimental paddy area are estimated at over 3,000 mm. The unit loads of pollutants in paddy fields area are determined by subtracting irrigation water load from outflow load (percolated and surface outflow loads). Surface outflow load in rainy days was calculated using the relationships of discharge and load, which are grouped into fertilizing and non-fertilizing periods. The ratios of the surface outflow load in rainy days to the total surface outflow load are 16.4% for T-N, 26.8% for T-P, and 23.3% far CODc,. The unit loads of pollutants show month-to-month and year-to-year variations, and monthly unit load of pollutants can show negative values, indicating that the paddy area acts as the pollutants sink. The average unit loads of the pollutants during irrigation seasons were estimated at 18.2 kg/ha fur T-N, 0.31 kg/ha for T-P, and 43.3 kg/ha for CODc,, which are smaller than the reported values for Kosei area in Japan.

Experimental Verification of Heat Sink for FPGA Thermal Control (FPGA 열제어용 히트싱크 효과의 실험적 검증)

  • Park, Jin-Han;Kim, Hyeon-Soo;Ko, Hyun-Suk;Jin, Bong-Cheol;Seo, Hak-Keum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.9
    • /
    • pp.789-794
    • /
    • 2014
  • The FPGA is used to the high speed digital satellite communication on the Digital Signal Process Unit of the next generation GEO communication satellite. The high capacity FPGA has the high power dissipation and it is difficult to satisfy the derating requirement of temperature. This matter is the major factor to degrade the equipment life and reliability. The thermal control at the equipment level has been worked through thermal conduction in the space environment. The FPGA of CCGA or BGA package type was mounted on printed circuit board, but the PCB has low efficient to the thermal control. For the FPGA heat dissipation, the heat sink was applied between part lid and housing of equipment and the performance of heat sink was confirmed via thermal vacuum test under the condition of space qualification level. The FPGA of high power dissipation has been difficult to apply for space application, but FPGA with heat sink could be used to space application with the derating temperature margin.

Design and Implementation of Green Coastal Lighting System for Entrance to Coastal Pier

  • Jae-Kyung Lee;Jae-Hong Yim
    • Journal of Navigation and Port Research
    • /
    • v.47 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • The hardware of an LED lighting control system for coastal lighting at coastal pier entrance consists of a power supply unit, an AVR control unit, a CLCD output unit, an LED control unit, a scenario selection switch unit, and an operation speed display unit. It is made of an 8-channel. The CPU used ATmega128 and the FET was used to control the current signal. To operate the CPU, DC 12V was converted to DC 5V using a regulator 7805. A heat sink was used to remove heat generated in the FET. By connecting the load LED module to the manufactured 8-channel LED lighting control system, the operation was confirmed through various production scenarios. In addition, a control system was designed to show the most suitable color for the atmosphere of the coastal pier according to the input value of temperature and illumination using a fuzzy control system. Computer simulation was then conducted. Results confirmed that fuzzy control did not need to store many data inputs due to characteristics of artificial intelligence and that it could efficiently represent many output values with simple fuzzy rules.

Runoff of Pollutant Loads from Paddy Field Area in a Dry Year (갈수년 광역논에서의 오염부하의 유출 특성)

  • Oh, Seung-Young;Kim, Jin-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.385-388
    • /
    • 2002
  • We investigated net outflow load and unit load of pollutants from a paddy fields area in dry year 2001. Amount of irrigation water in 2001 was about 61-63% of that in previous years 1999 and 2000 due to drought. The net outflow load and unit load of pollutants in 2001 were negative, showing that paddy fields acts as sink of pollutants due to function of water quality purification. The relationship between unit load of pollutants and net surface outflow (= surface outflow - irrigation water) showed positive correlation. The results showed that abatement of surface outflow by appropriate water management contribute to reduce surface outflow load from paddy fields.

  • PDF

Study on the Design and the Prototype Manufacture of Cooling systems of the Propulsion System for the EMU (동력분산형 고속전철의 추진시스템용 냉각장치 설계 및 시제품 제작 연구)

  • Ryoo, Seong-Ryoul;Kim, Sung-Dae;Ki, Jae-Hyung;Yim, Kwang-Bin;Kim, Chul-Ju
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.422-429
    • /
    • 2008
  • The objective of the present study is to develope a propultion unit cooling system for the next-generation High-speed EMU. The propulsion power control unit consists of some IGBT semiconductors. In general, those power semiconductors are very sensitive to temperatures and need a cooling system to keep them at a proper operational conditions in the range of $50{\sim}100^{\circ}C$. In this first year of study, we tried to focuss on the understanding of fundamental technologies for each of the two different cooling systems and collecting basic data for design and manufacturing for both cases. For the water cooling system, a heat sink with multi channels of liquid flow was considered and a model unit was designed and performance test was conducted. For the heat pipe cooling system, a Loop Heat Pipe(LHP) was considered as an element to transport heat from IGBT to environment air flow and a model unit was designed and performance test was conducted. The analysis using SINDA/FLUINT showed that those design parameters are good enough for the LHP to properly operate under a heat load up to around 360W.

  • PDF

Study on Evaluation Method of Thermal Potential of Unused Energy (미활용에너지의 열 포텐셜 평가 수법에 관한 연구)

  • Chung, Yong-Hyun
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.493-501
    • /
    • 2006
  • The increase in environmental loads and energy consumptions has resulted in the need of developed new forms of energy for a sustainable use for the society. Recently, the viability of using unused energy has attracted a great deal of attention. From the view point of using unused energy, the most critical problem can be referred to as the distance between the heat source/sink and heat demand area. The water resource in the city water system was used to solve this distance problem with unused energy. The calculation method of the potential use unit was used to survey the potential of the water resource in the city water system. The amount of theoretical unused energy and energy savings in the model city were estimated using this method. It is estimated that the amounts of energy savings and $CO_2$ reduction correspond to 131.3 GWh and 29280[t-C], respectively, per annual basis.

Growth and Yield of Atractylodes japonica Koidz. Affected by Shading and Flower Bud Pinching (차광 및 화뢰제거가 삽주의 생육 및 수량에 미치는 영향)

  • Park, Jeong-Min;Kang, Jin-Ho;Kim, Man-Bae
    • Korean Journal of Medicinal Crop Science
    • /
    • v.12 no.3
    • /
    • pp.231-236
    • /
    • 2004
  • Crop productivity would be determined by relative capacity of source and sink. The study was carried out to measure the effects of shading and flower bud pinching on growth and yield of Atractylodes japonica Koidz. Shading treatment after transplanting was done at 100%, 65, 45 or 25% level of natural light intensity but the pinching treatment was to remove all the inflorescences formed after June 10, July 10, August 10 or none. Growth and yield at early and late stages were periodically measured. At the early stage, shading mainly influenced fresh weight rather than morphological characters. At the late stage, however, severer shading decreased numbers of stems, leaves, roots, fraction and total fresh weight. 65% shading from July 1 to September 30 after skipped the emerging and early growth stages showed nearly same growth and morphological characters but more rhizome yield per unit area than non-shading. In flower bud pinching treatment, earlier pinching increased number of roots, fraction fresh weights per plant and rhizome yield per unit area.

Estimation of Carbon Storage for Trees in Forest Ecosystem in the National Parks of Korea (한국 국립공원 산림생태계의 수목 탄소저장량 평가)

  • Lee, Sang-Jin;Park, Hong-Chul;Park, Gwan-Soo;Kim, Hyoun-Sook;Lee, Chang-Min;Kim, Jin-Won;Sim, Gyu-Won;Choi, Seung-Woon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.3
    • /
    • pp.1-16
    • /
    • 2022
  • The purpose of this study is to quantitatively evaluate the amount of carbon storage for trees in forest ecosystem to support the foundation for carbon neutrality implementation in Korea National Park. It targeted 22 national parks designated and managed as national parks in Korea, and conducted research on forest trees in the terrestrial ecosystem among various natural and ecological carbon sink. The survey and analysis method followed the IPCC guidelines and the National Greenhouse Gas Inventory in Korea. The amount of tree carbon storage in the forest ecosystem of Korea National Park was confirmed to be about 218,505 thousand CO2-ton and the amount of carbon storage per unit area was 570.8 CO2-ton per hectare. Compared to 299.7 CO2-ton per hectare, the average carbon storage per unit area of the entire Korean forest, it was found that about twice as much carbon was stored when assuming the same area. In other words, it means that the tree carbon storage function of the national park is about twice as high as that of the average tree carbon storage function of entire Korean forest. It has great implications in Korea National Park not only provides biodiversity promotion and exploration services as a national protected area, but also performs excellent functions as a carbon sink.

Development of LED Module Control-based PWM Current for Control of Heat-dissipation (방열특성 제어를 위한 PWM 전류제어 기반 LED 모듈 개발)

  • Lee, Seung-Hyun;Moon, Han Joo;Hue, Seong-bum;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.129-135
    • /
    • 2015
  • This paper shows significant methods that improve the lifespan of LED modules as well as efficiently using an aluminum heat-sink for LED module in high power. It proposes a method that raises stability and lifespan to protect LED modules and the power unit when the LED module has been used for a long hours at high temperatures. During the research, we applied a method of pulse-width modulation (PWM) in order to prevent the phenomenon that the entire power of a system is turned off and the lifespan is reduced when the LED nodule reacts to the high temperatures. To protect the LED module and SMPS based on high efficiency, a temperature sensor is attached underneath the circuit board and the sensor measures the temperature of circuit board when the LED module is powered on. The electrical power connected to SMPS is controlled by PWM when the temperature of the LED module reaches a particular temperature.