• 제목/요약/키워드: Single-junction

검색결과 309건 처리시간 0.023초

RF 마그네트론 스퍼터링법으로 증착된 CdS 박막의 CdCl2 열처리 효과 (Effects of CdCl2 Heat Treatment on the Qualities of CdS Thin Films Deposited by RF Magnetron Sputtering Technique)

  • 최수영;천승주;정영훈;이승훈;배수현;탁성주;김지현;김동환
    • 한국재료학회지
    • /
    • 제21권9호
    • /
    • pp.497-501
    • /
    • 2011
  • The CdS thin film used as a window layer in the CdTe thin film solar cell transports photo-generated electrons to the front contact and forms a p-n junction with the CdTe layer. This is why the electrical, optical, and surface properties of the CdS thin film influence the efficiency of the CdTe thin film solar cell. When CdTe thin film solar cells are fabricated, a heat treatment is done to improve the qualities of the CdS thin films. Of the many types of heat treatments, the $CdCl_2$ heat treatment is most widely used because the grain size in CdS thin films increases and interdiffusion between the CdS and the CdTe layer is prevented by the heat treatment. To investigate the changes in the electrical, optical, and surface properties and the crystallinity of the CdS thin films due to heat treatment, CdS thin films were deposited on FTO/glass substrates by the rf magnetron sputtering technique, and then a $CdCl_2$ heat treatment was carried out. After the $CdCl_2$ heat treatment, the clustershaped grains in the CdS thin film increased in size and their boundaries became faint. XRD results show that the crystallinity improved and the crystalline size increased from 15 to 42 nm. The resistivity of the CdS single layer decreased from 3.87 to 0.26 ${\Omega}cm$, and the transmittance in the visible region increased from 64% to 74%.

구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향 (THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR)

  • 이강;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제27권5호
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.

닭의 자궁과 질 접합부의 정자선내에 정자 저장 (Sperm storage of the utero-vaginal glands in domestic hens)

  • 류재두;곽수동
    • 대한수의학회지
    • /
    • 제30권4호
    • /
    • pp.361-371
    • /
    • 1990
  • The present observations were focussed mainly on the morphological findings of the utero-vaginal(U-V) glands in normal laying domestic hens and the storage of cock spermatozoa in the U-V glands at various times after artificial insemination(AI). These domestic hens were assigned to three group of PMS-treated, GnRH-treated before last AI, and control group. The hens were sacrified at intervals of 1,3,7,12 and 19 days after AI. Histological sections of U-V junctions were prepared and the morphological structures of the U-V glands were observed and then were scored about the spermatozoa presence in the U-V gland. 1. The U-V glandular tubules were mostly unbranched with single columnar epithelium. Also these tubules were occassionally observed as one circular-rotated tubules or 2 to 3 branched convoluted tubules in special shapes. The numbers of the convoluted curves per tubule were $4.3{\pm}3.3$ and the ranges of convoluted curve number were straight to 16 curves. 2. The inside and outside diameters of the glandular tubules were $6.5{\pm}3.5{\mu}m$, and $35.2{\pm}4.7{\mu}m$, respectively, and the tubular lengths of the U-V glands were $219.3{\pm}115.7{\mu}m$. 3. Storaged spermatozoa in the U-V glands of all three group hens were intensively stained by hematoxylin, and packed in tight, longitudinally parallel bundles within the tubules. In addition, numbers of completely spermatozoa-filled glands were tend to increase or decrease in proportion to the numbers of partially spermatozoa-filled glands. Also U-V glands containing spermatozoa tend to be present collectively in the any zone of U-V junction. 4. In the control group, the numbers of glands containing spermatozoa in the hens at 1,3,7,12, and 19 days after AI were found to be 22.9, 33.3, 35.8, 8.6, and 0% respectively. 5. In the PMS-treated group, the numbers of glands containing spermatozoa in the hens at 1,3,7,12, and 19 days after AI were found to be 33.6, 29.7, 26.8, 8.2 and 0% respectively. 6. In the GnRH-treated group, the numbers of glands containing spermatozoa in the hens at 1,3,7,12, and 19 days after AI were found to be 19.7, 40.8, 20.4, and 0% respectively.

  • PDF

상아세관 폐쇄에 대한 2종의 상아질 지각 과민 체치제와 Er,Cr:YSGG 레이저의 효과 (Effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion)

  • 김나송;강정경;류재준
    • 대한치과의사협회지
    • /
    • 제48권6호
    • /
    • pp.469-477
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion. Twenty recently extracted single-rooted human teeth were used to obtain root dentinal fragments. The crowns were cut approximately 1mm below the cementum enamel junction(CEJ). A second cut was used to remove the apex of the root. Subsequently, a longitudinal cut was made in order to obtain 2 fragments from each root sample. The cementum from the cervical portion was removed using a high-speed diamond-coated bur in order to expose the dentin. To open dentinal tubules, forty samples were treated with 50% citric acid for 2 min and then rinsed under distilled water for 1 min. These were divided into four groups of ten samples each. The first group served as a control group. In group 2, the samples were irradiated with the Er,Cr:YSGG laser(Waterlase MD, Biolase, USA). In group 3, the samples were treated with Bisblock and ONE-STEP PLUS(Bisco, USA). In group 4, the samples were treated with Gluma comfort bond & Desensitizer(Heraeus Kulzer, Germany). All the samples were examined using Scanning electron microscopy(Hitachi, S-4700, Japan) with two different magnifications(X2000, X5000). These images were assessed by one examiner who was blind to the experimental procedure, using the index of smear layer removal. The distribution of smear layer removal grades was tested using Fisher's exact test. On the order hand, in order to evaluate the occluding effect of two dentin desensitizers and Er,Cr:YSGG laser, the number of exposed dentinal tubules was counted in each group. These were evaluated using the Kruskal-Wallis test with significance predetermined $\alpha$=0.05. There were statistically significant differences between the three groups(Er,Cr:YSGG laser, Bisblock+ONE-STEP PLUS, Gluma comfort bond & Desensitizer) and control group.

근관내 약제가 규산칼슘 기반 재료의 압출 강도에 미치는 영향 (Effect of Intracanal Medicaments on Push-out Bond Strength of Calcium Silicate-based Materials)

  • 정현태;양선미;김선미;최남기;김재환
    • 대한소아치과학회지
    • /
    • 제45권4호
    • /
    • pp.455-463
    • /
    • 2018
  • 이 연구의 목적은 근관 내 약제가 규산칼슘 재료의 압출 강도(Push-out bond strength)에 미치는 영향을 평가하는 것이다. 단일 근관을 가진 40개의 인간 하악 소구치들은 대조군과 수산화칼슘, 이중 항생제, 삼중 항생제를 사용한 군 중 하나로 나뉘어졌다. 근관 세척을 통해 약제를 제거 후, 1 mm 두께로 시편들을 제작하였다. 그 후 ProRoot MTA$^{(R)}$와 Biodentine$^{(R)}$을 근관 내에 적용하였고, 압출 강도 실험과 파절 양상 관찰을 수행하였다. 삼중 항생제와 이중 항생제 군은 대조군과 비교하여 두 종류의 규산칼슘 기반 재료의 상아질 결합력에서 유의한 영향을 미치지 않았고, 수산화칼슘을 사용한 군은 유의한 결합력의 증가를 나타내었다. 대조군과 각각의 실험군 내에서 치근 상아질에 대한 Biodentine$^{(R)}$의 탈락 저항은 ProRoot MTA$^{(R)}$보다 크게 나타났다. 파절 양상에 따라 응집 파절, 혼합 파절, 접착 파절의 순서로 압출 강도의 유의한 감소가 나타났고, 대조군과 비교하여 수산화칼슘을 사용한 군에서는 응집 파절이, 항생제를 사용한 군에서는 접착 파절이 우세하였다.

Synthesis of Uniformly Doped Ge Nanowires with Carbon Sheath

  • 김태헌;장야무진;최순형;서영민;이종철;황동훈;김대원;최윤정;황성우;황동목
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.289-289
    • /
    • 2013
  • While there are plenty of studies on synthesizing semiconducting germanium nanowires (Ge NWs) by vapor-liquid-solid (VLS) process, it is difficult to inject dopants into them with uniform dopants distribution due to vapor-solid (VS) deposition. In particular, as precursors and dopants such as germane ($GeH_4$), phosphine ($PH_3$) or diborane ($B_2H_6$) incorporate through sidewall of nanowire, it is hard to obtain the structural and electrical uniformity of Ge NWs. Moreover, the drastic tapered structure of Ge NWs is observed when it is synthesized at high temperature over $400^{\circ}C$ because of excessive VS deposition. In 2006, Emanuel Tutuc et al. demonstrated Ge NW pn junction using p-type shell as depleted layer. However, it could not be prevented from undesirable VS deposition and it still kept the tapered structures of Ge NWs as a result. Herein, we adopt $C_2H_2$ gas in order to passivate Ge NWs with carbon sheath, which makes the entire Ge NWs uniform at even higher temperature over $450^{\circ}C$. We can also synthesize non-tapered and uniformly doped Ge NWs, restricting incorporation of excess germanium on the surface. The Ge NWs with carbon sheath are grown via VLS process on a $Si/SiO_2$ substrate coated 2 nm Au film. Thin Au film is thermally evaporated on a $Si/SiO_2$ substrate. The NW is grown flowing $GeH_4$, HCl, $C_2H_2$ and PH3 for n-type, $B_2H_6$ for p-type at a total pressure of 15 Torr and temperatures of $480{\sim}500^{\circ}C$. Scanning electron microscopy (SEM) reveals clear surface of the Ge NWs synthesized at $500^{\circ}C$. Raman spectroscopy peaked at about ~300 $cm^{-1}$ indicates it is comprised of single crystalline germanium in the core of Ge NWs and it is proved to be covered by thin amorphous carbon by two peaks of 1330 $cm^{-1}$ (D-band) and 1590 $cm^{-1}$ (G-band). Furthermore, the electrical performances of Ge NWs doped with boron and phosphorus are measured by field effect transistor (FET) and they shows typical curves of p-type and n-type FET. It is expected to have general potentials for development of logic devices and solar cells using p-type and n-type Ge NWs with carbon sheath.

  • PDF

L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기 (Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band)

  • 황지환;권순구;주정명;오이석
    • 한국전자파학회논문지
    • /
    • 제22권7호
    • /
    • pp.711-719
    • /
    • 2011
  • 본 논문에서는 L-밴드 대역 레이더 후방 산란 측정용 도파관 직교 모드 변환기(orthomode transducer)의 소형화에 대한 설계 및 성능 분석 결과를 제시한다. 도파관 직교 모드 변환기는 테이퍼(taper) 구조를 기본으로 새롭게 설계된 접합 구조를 이용하여 별도의 테이퍼 구조 없이 표준 어댑터와 연결이 가능하도록 설계/제작되었다. 소형화된 L-밴드 직교 모드 변환기의 최대 길이는 약 1.2 ${\lambda}_o$(310 mm)이며, 이는 기존의 동급 직교 모드 변환기 크기의 약 60 % 수준이 된다. 또한, 직교 모드 변환기의 포트 정합 특성과 편파 격리도 특성을 높이기 위해서 두 개의 금속봉을 구조 내부에 삽입하여 운용 주파수 대역 내 420 MHz의 대역폭(반사 손실<-15 dB 이하)과 약 40 dB의 높은 편파 격리도 성능을 얻을 수 있었다. 제작된 직교 모드 변환기, 혼 안테나, 네트워크 분석기(Agilent사(社)8753E)로 구성된 L-밴드 scatterometer를 이용한 레이더 후방 산란 측정의 정확도 분석을 위해 STCT(Single Target Calibration Technique) 보정 기법과 2DTST(2D Target Scanning Technique) 자동 측정 기법을 이용하였다. 보정된 scatterometer를 이용하여 측정된 시험용 목표물(55 cm 삼각 수동 전파 반사기)의 RCS(Radar Cross Section)의 측정 오차는 수직/수평 편파 각각 -0.2 dB와 0.25 dB이며, 유효 편파 격리도는 대역 내 평균 약 35.8 dB이다. 이때, 성능 측정을 위해 직교 모드 변환기와 함께 사용된 혼 안테나는 길이 300 mm, 개구면 크기 $450{\times}450\;mm^2$이며, E-평면 $29.5^{\circ}$와 H-평면 $36.5^{\circ}$의 반전력 빔 폭(HPBW)을 갖는다.

수 종의 복합레진 접착 시스템에서의 미세 누출의 비교 (COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS)

  • 석충기;남동우;남순현;김영진;김현정
    • 대한소아치과학회지
    • /
    • 제31권4호
    • /
    • pp.636-644
    • /
    • 2004
  • 최근 자가 부식형 접착 시스템이 개발되어 법랑질 및 상아질에 모두 적용할 수 있고, 임상적 술식을 단순화 시켰다. 이 접착 시스템은 적용하기 용이하고 임상적으로도 법랑질 및 상아질에 높은 결합강도를 보인다고 보고되고 있다. 이 연구는 in vitro 상에서 복합레진 5급 와동의 법랑질 및 상아질 경계에서 전부식 처리를 동반한 one-bottle 접착시스템과 자가 부식형 접착 시스템을 사용하였을 때 미세 누출을 비교하기 위해 시행하였다. 교정적 목적으로 발치된 30개의 소구치를 무작위적으로 3개 군으로 나누었다; 1 군 (Single $Bond^{(R)}$ + Filtek $Z250^{(R)}$), 2 군 (Clearfil SE $Bond^{(R)}$ + Filtek $Z250^{(R)}$), 3 군 (Adper Prompt $L-Pop^{(R)}$ + Filtek $Z250^{(R)}$). 표준화된 5급 와동을 각 소구치 협면, 설면에서 백악-법랑경계에 평행하게 형성하였으며, 와동의 치은측 1/2은 백악법랑경계보다 1mm 치근단으로 연장하였다. 접착 시스템을 제조자의 지시대로 적용한 다음 복합레진을 충전하고 제조자의 지시대로 광중합하였다. 시편을 $37^{\circ}C$ 증류수에 5일 간 보관 후 $5^{\circ}C{\pm}2^{\circ}C$$55^{\circ}C{\pm}2^{\circ}$에서 1000회 열순환한 다음, 2% methylene blue 용액에 12시간 침잠시켰다. $Isomet^{TM}$ (Buehler Co., Lake Bluff, IL, USA)을 사용하여 치아를 충전물 중앙에서 종절단한 후 입체 현미 경하에서 25배의 배율로 색소 침투도를 평가하였다. 결과는 t-test 와 one-way ANOVA를 이용하여 통계처리 하였다. 결과는 다음과 같았다. ${\cdot}$ 실험에 사용 된 접착 시스템 중에 미세 누출을 완벽하게 방지하는 접착 시스템은 없었다. ${\cdot}$ 상아질 경계에서의 미세 누출이 법랑질 경계에서보다 통계학적으로 유의하게 더 많았다(p<0.0001). ${\cdot}$ 법랑질 경계에서 자가 부식형 접착 시스템은 전부식 처리를 동반한 one-bottle접착 시스템과 통계학적으로 유의한 차이를 보이지 않았다. ${\cdot}$ 상아질 경계에서, 자가 부식형 접착 시스템은 전부식 처리를 동반한 one-bottle 접착 시스템과 통계학적으로 유의한 차이를 보이지 않았다.

  • PDF

수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가 (Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments)

  • 신유석;신수정;송민주;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.300-305
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 원형의 치근단 삭제를 제공하는 능력에 관한 수 종의 Ni-Ti 회전 기구들을 평가하는 것이다. 연구 재료 및 방법: 실험은 50개의 단근치를 선택하여 백악상아질 경계에서 절단하였고, 근관의 치관부 1/3은 Gates Glidden bur (#2, #3, #4)를 이용하여 확대하였다. 시편들은 각 군당 10개씩 5개의 실험군들로 나누었다. 1군은 GT file, Profile .04, Quantec #9, #10을 사용했고, 2군은 1군과 유사하나 Quantec 파일 대신 Lightspeed를 사용했고, 3군은 Orifice shaper, Profile .06 종류들, Lightspeed를 사용했고, 4군은 3군과 유사하나 Lightspeed 대신 Quantec #9, #10를 사용했고, 5군은 근관 확대를 위해 GT file, Profile .04를 사용했다. 모든 치아 시편들은 치근첨으로부터 1 mm, 3 mm, 5 mm에서 절단하여 현미경하에서 관찰했다. 결과: 본 연구의 결과 실험군 2, 3군(Lightspeed file군)이 실험군 1, 4군(Quantec), 실험군 5군(GT file, profile .04종류들)에 비하여 치근단 1 mm에서 더 원형에 가까운 치근단 삭제를 보였다(p < 0.05). 치근단 3, 5 mm들에서는 각 군들 사이에서 통계학적 유의차가 없었다. 치근단 5 mm 시편들에서는 대부분의 시편들이 완전한 원형을 나타내었으며 불규칙한 모양은 관찰되지 않았다. 결론: 치근단 1 mm 시편에서 Lightspeed를 사용한 경우에서 다른 Quantec, GT와 Profile .04 종류들을 사용한 것보다 더 원형의 삭제를 얻었고, 근관장에서 최초의 Lightspeed에 맞는 크기보다 ISO 크기보다 3단계 크기 확대로는 모든 치근단 1 mm에서 원형의 삭제를 얻었을 수 없었고 단지 35%에서만 원형의 삭제를 얻을 수 있었다는 것이다. 따라서 ISO 크기보다 3단계 크기 확대가 원형 삭제를 얻기에는 불충분하며 좀 더 큰 크기로 확대하는 것이 필요함을 알 수 있으나 치아에 따라 치근단 부위 치질의 양이 다를 수 있으므로 일률적으로 적용하기에는 무리가 있을 수 있다.