• Title/Summary/Keyword: Single vision lens

Search Result 31, Processing Time 0.023 seconds

TEST OF A LOW COST VEHICLE-BORNE 360 DEGREE PANORAMA IMAGE SYSTEM

  • Kim, Moon-Gie;Sung, Jung-Gon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.137-140
    • /
    • 2008
  • Recently many areas require wide field of view images. Such as surveillance, virtual reality, navigation and 3D scene reconstruction. Conventional camera systems have a limited filed of view and provide partial information about the scene. however, omni directional vision system can overcome these disadvantages. Acquiring 360 degree panorama images requires expensive omni camera lens. In this study, 360 degree panorama image was tested using a low cost optical reflector which captures 360 degree panoramic views with single shot. This 360 degree panorama image system can be used with detailed positional information from GPS/INS. Through this study result, we show 360 degree panorama image is very effective tool for mobile monitoring system.

  • PDF

Depth Map Using New Single Lens Stereo (단안렌즈 스테레오를 이용한 깊이 지도)

  • Changwun Ku;Junghee Jeon;Kim, Choongwon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1157-1163
    • /
    • 2000
  • In this paper, we present a novel and practical stereo vision system that uses only one camera and four mirrors placed in front of the camera. The equivalent of a stereo pair of images are formed as left and right halves of a single CCD image by using four mirrors placed in front of the ten of a CCD camera. An object arbitrary point in 3D space is transformed into two virtual points by the four mirrors. As in the conventional stereo system, the displacement between the two conjugate image points of the two virtual points is directly related to the depth of the object point. This system has the following advantages over traditional two camera stereo that identical system parameters, easy calibration and easy acquisition of stereo data.

  • PDF

A study on Monovision of Fitting soft contact lenses for College students (대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2004
  • Monovision is defined as correcting one eye for distance vision and the other eye for near vision. Single-vision contact lenses are used for each eye. The patient selectively suppresses one eye while using the other eye. This study was performed to measure binocular function and patient satisfaction with monovision induced by adding +3.00D to spectacle prescription for distance vision in nonpresbyopic students. This study comprised 144 nonpresbyopic students with monovision induced by adding +3.00D to spectacle prescription. Monovision was induced by undercorrecting the nondominant eye by adding 3.00 diopters for near vision and correcting the dominant eye with emmetropia for distance vision. For research of the binocular function on Monovision. This study was tested the obstacle course, water pouring test, catching and throwing, bead classification including the stereopsis test. These tests were comparative to the normal binocular state. As a results, the stereopsis have a significant reductions in Monovision. There was no significantly difference between monovision group and control group in monovision exercise (obstacle course, water pouring test, catching and throwing, and bead sorting) at near and distance. This study indicates that monovision is an effective and reasonable therapeutic modality for correcting presbyopia. By the application of above methods, this study could be used the student for the practical practice and understand on the Monovison.

  • PDF

Autofocus of Infinity-Corrected Optical Microscopes by Confocal Principle and Fiber Source Modulation Technique (공초점 원리와 광섬유 광원 변조를 이용한 무한보정 현미경 자동초점)

  • Park, Jung-Jae;Kim, Seung-Woo;Lee, Ho-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.583-590
    • /
    • 2004
  • The autofocus is one of the important processes in the automated vision inspection or measurements using optical microscopes, because it influences the measuring accuracy. In this paper, we used the confocal microscope configuration based on not a pinhole but a single-mode optical fiber. A single mode fiber has the functions of source and detector by applying the reciprocal scheme. As a result, we acquired a simple system configuration and easy alignment of the optical axis. Also, we embodied a fast autofocus system by acquiring the focus error signal through a source modulation technique. The source modulation technique can effectively reduce physical disturbances compared with objective lens modulation, and it is easily applicable to general optical microscopes. The focus error signal was measured with respect to the modulation amplitude, reflectance of the specimen and inclination angle of the measuring surface. The performance of the proposed autofocus system was verified through autofocusing flat mirror surface. In addition, we confirmed that source modulation rarely degrades the depth resolution by the comparison between the FWHMs of axial response curves.

Eyes and Vision of the Bumblebee: a Brief Review on how Bumblebees Detect and Perceive Flowers

  • Meyer-Rochow, V.B.
    • Journal of Apiculture
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2019
  • Bumblebees have apposition compound eyes (one on either side of the head) of about 6,000 ommatidia and three small single-lens ocelli on the frons of their head capsule. The surface of the eye is smooth and interommatidial hairs, as in the honeybee, are not developed. Each ommatidium (approx. 26 ㎛ in diameter) is capped by a hexagonal facet and contains in its centre a 3 ㎛ wide, columnar light-perceiving structure known as the rhabdom. Rhabdoms consist of thousands of regularly aligned, fingerlike microvilli, which in their membranes contain the photopigment molecules. Axons from each ommatidium transmit the information of their photic environment to the visual centres of the brain, where behavioural reactions may be initiated. Since bumblebee eyes possess three classes of spectrally different sensitivity peaks in a ratio of 1:1:6 (UV= 353 nm, blue= 430 nm and green=548 nm) per ommatidium, they use colour vision to find and select flower types that yield pollen and nectar. Ommatidial acceptance angles of at least 3° are used by the bumblebees to discriminate between different flower shapes and sizes, but their ability to detect polarized light appears to be used only for navigational purposes. A flicker fusion frequency of around 110Hz helps the fast flying bumblebee to avoid obstacles. The small ocelli are strongly sensitive to ultraviolet radiation and green wavelengths and appear to act as sensors for light levels akin to a photometer. Unlike the bumblebee's compound eyes, the ocelli would, however, be incapable of forming a useful image.

IMPLEMENTATION OFWHOLE SHAPE MEASUREMENT SYSTEM USING A CYLINDRICAL MIRROR

  • Uranishi, Yuki;Manabe, Yoshitsugu;Sasaki, Hiroshi;Chihara, Kunihiro
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.601-605
    • /
    • 2009
  • We have proposed a measurement system for measuring a whole shape of an object easily. The proposed system consists of a camera and a cylinder whose inside is coated by a mirror layer. A target object is placed inside the cylinder and an image is captured by the camera from right above. The captured image includes sets of points that are observed from multiple viewpoints: one is observed directly, and others are observed via the mirror. Therefore, the whole shape of the object can be measured using stereo vision in a single shot. This paper shows that a prototype of the proposed system was implemented and an actual object was measured using the prototype. A method based on a pattern matching which uses a value of SSD (Sum of Squared Difference), and a method based on DP (Dynamic Programming) are employed to identify a set of corresponding points in warped captured images.

  • PDF

Comparison of Accommodative Function of Young Adults in their Twenties Wearing Monovision, Modified Monovision and Multifocal Soft Contact Lenses (모노비전, 변형된 모노비전, 멀티포컬 콘택트렌즈로 교정 시 20대 성인의 조절기능 비교)

  • Lee, A-Young;Kim, Jeong-Mee;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.117-124
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accommodative function of young adult in their 20s wearing monovision, modified monovision, and aspheric multifocal contact lenses at near task. Methods: Thirty young adults ($23.53{\pm}2.37years$) were fitted with monovision, modified monovision (the application of single vision contact lenses and center-near low addition aspheric multifocal contact lenses), and aspheric center-near multifocal contact lenses. After wearing these modalities during a week for adaption, and after watching visual display at computer for inducing accommodative pressure for 1 hour. The following assessments of accommodative function were made: contrast visual acuity (VA) at distance and near; accommodative response; near accommodative facility; and negative relative accommodation (NRA)/positive relative accommodation (PRA). All measurements were carried out binocularly. Results: In binocular distance VA with contrast of 10%, monovision was the worst among the four modalities (p=0.005). In accommodative response at 1 m (1.00 D), monovision was the lowest (p<0.05) and accommodative response at 40 cm (2.50 D) with monovision was lower than that of modified monovision and multifocal contact lens (p<0.05). We also found that there were no significant differences in accommodative facility and NRA/PRA among the four modalities. Conclusions: In young adult (20s), monovision with low add reduced the accommodative response at near task, however, modified monovision and multifocal lens with center-near type did not affect accommodative relaxation.

Catadioptric Omnidirectional Optical System Using a Spherical Mirror with a Central Hole and a Plane Mirror for Visible Light (중심 구멍이 있는 구면거울과 평면거울을 이용한 가시광용 반사굴절식 전방위 광학계)

  • Seo, Hyeon Jin;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.88-97
    • /
    • 2015
  • An omnidirectional optical system can be described as a special optical system that images in real time a panoramic image with an azimuthal angle of $360^{\circ}$ and the altitude angle corresponding to the upper and lower fields of view from the horizon line. In this paper, for easy fabrication and compact size, we designed and fabricated a catadioptric omnidirectional optical system consisting of the mirror part of a spherical mirror with a central hole (that is, obscuration), a plane mirror, the imaging lens part of 3 single spherical lenses, and a spherical doublet in the visible light spectrum. We evaluated its image performance by measuring the cut-off spatial frequency using automobile license plates, and the vertical field of view using an ISO 12233 chart. We achieved a catadioptric omnidirectional optical system with vertical field of view from $+53^{\circ}$ to $-17^{\circ}$ and an azimuthal angle of $360^{\circ}$. This optical system cleaniy imaged letters on a car's front license plate at the object distance of 3 meters, which corresponds to a cut-off spatial frequency of 135 lp/mm.

Safety Evaluation of the Lighting at the Entrance of a Very Long Road Tunnel: A Case Study in Ilam

  • Mehri, Ahmad;Hajizadeh, Roohalah;Dehghan, Somayeh Farhang;Nassiri, Parvin;Jafari, Sayed Mohammad;Taheri, Fereshteh;Zakerian, Seyed Abolfazl
    • Safety and Health at Work
    • /
    • v.8 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Background: At the entrance of a tunnel, reflection of sunlight from the surrounding environment and a lack of adequate lighting usually cause some vision problems. The purpose of this study was to perform a safety evaluation of lighting on a very long road in Ilam, Iran. Methods: The average luminance was measured using a luminance meter (model S3; Hagner, Solna, Sweden). A camera (model 108, 35-mm single-lens reflex; Yashica, Nagano, Japan) was used to take photographs of the safe stopping distance from the tunnel entrance. Equivalent luminance was determined according to the Holliday polar diagram. Results: Considering the average luminance at the tunnel entrance ($116.7cd/m^2$) and using Adrian's equation, the safe level of lighting at the entrance of the tunnel was determined to be 0.7. Conclusion: A comparison between the results of the safe levels of lighting at the entrance of the tunnel and the De Boer scale showed that the phenomenon of black holes is created at the tunnel entrance. This may lead to a misadaptation of the drivers' eyes to the change in luminance level at the entrance of the tunnel, thereby increasing the risk of road accidents in this zone.

A Case of Mitochondrial Respiratory Chain Defect with Progressive Bilateral Cararacts (진행성 양측 백내장이 동반된 미토콘드리아 질환 1례)

  • Lee, Soonie;Lee, Young-Mock
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.18 no.3
    • /
    • pp.95-98
    • /
    • 2018
  • A striking feature of mitochondrial disorders is the vast heterogeneity in their clinical symptoms that ranges from a single organ to severe multisystem involvement. Though a variety of ocular symptoms such as ptosis, pigmentary retinal degeneration, external ophthalmoplegia, and optic nerve atrophy can occur in association with mitochondrial cytopathies, progressive bilateral cataracts are rare among their ocular findings. A 5-year-old girl with no previous medical history came to our hospital presenting symptoms of seizure. She started showing progressive developmental regression, increased seizure frequency, hypotonia, general weakness, dysphagia and decreased vision. Lactic acidosis was noted in metabolic screening test and we confirmed mitochondrial respiratory chain complex I defect in spectrophotometric enzyme assay using the muscle tissue. Progressive bilateral cataracts then developed and were fully evident at the age of 7. She underwent cataract extraction with posterior chamber lens implantation. We are reporting a case of mitochondrial respiratory chain defect with multiorgan involvements including bilateral progressive cataract, an uncommon ocular manifestation. Ophthalmologic evaluation is highly recommended not to overlook the possible ocular manifestations in mitochondrial disorders.

  • PDF