• 제목/요약/키워드: Single source

검색결과 2,220건 처리시간 0.028초

Contention-based Reservation Protocol Using a Counter for Detecting a Source Conflict in WDM Single-hop Optical Network with Non-equivalent Distance

  • Sakuta, Makoto;Nishino, Yoshiyuki;Sasase, Iwao
    • Journal of Communications and Networks
    • /
    • 제3권4호
    • /
    • pp.365-373
    • /
    • 2001
  • We propose a new channel reservation protocol which can reduce message delay by using a counter for detection of d source conflict in a WDM single-hop network with non-equivalent propagation delay. A source convict occurs when a source node has the right to transmit more than or equal to two messages simultaneously, which are transmitted using different wavelengths. In such a case, the source node has to newly obtain the right to transmit the message. In the proposed protocol, by using a source conflict counter a source node can detect a source conflict before a wave-length assignment is performed. Therefore, the source node can start a procedure to newly obtain the right to transmit the message which cannot be transmitted due to a source conflict. We analyse the throughput performance by taking the effect of a source conflict into account, and show that the approximate analysis and the computer simulated results are close. Also, from computer simulated results, we show that our proposed protocol can reduce mean message delay dramatically without degrading throughput performance as the offered load becomes large.

  • PDF

Optimizing Effective Channel Length to Minimize Short Channel Effects in Sub-50 nm Single/Double Gate SOI MOSFETs

  • Sharma, Sudhansh;Kumar, Pawan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권2호
    • /
    • pp.170-177
    • /
    • 2008
  • In the present work a methodology to minimize short channel effects (SCEs) by modulating the effective channel length is proposed to design 25 nm single and double gate-source/drain underlap MOSFETs. The analysis is based on the evaluation of the ratio of effective channel length to natural/ characteristic length. Our results show that for this ratio to be greater than 2, steeper source/drain doping gradients along with wider source/drain roll-off widths will be required for both devices. In order to enhance short channel immunity, the ratio of source/drain roll-off width to lateral straggle should be greater than 2 for a wide range of source/drain doping gradients.

공기열원 2중히트싱크 열펌프의 성능해석 (Performance Analysis of Heat Pump System with Air Source Evaporator and Single Unit Dual Sink Condenser)

  • 우정선;이세균;이재효;박효순
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.11-22
    • /
    • 1998
  • Floor panel heating system using hot water is the primary heating system of domestic residential building. This paper presents the results of performance analysis of the heat pump system with air source evaporator and single unit dual sink(SUDSk) condenser. The heat exchanger combines two separated condensers into a single condenser and the object of the SUDSk condenser is to release energy to dual sinks, i.e. air for air heating system and water for panel heating system in one single unit. Simulation program is developed for single unit dual source(SUDS) SUDSk heat pump system and some experimental data are obtained and compared with simulation results. Differences of heating capacity and COP in dual source operating mode are 7% and 8% respectively. Simulation results are in good agreement with test results. Therefore, developed program is effectively used for design and performance prediction of dual source dual sink heat pump system with SUDS evaporator and SUDSk condenser.

  • PDF

예측 상태 관측기를 이용한 3상 전압 원 PWM 컨버터의 단일 센서 전류 제어 (Single Sensor Current Control for Three-Phase Voltage-Source PWM Converters Using a Predictive State Observer)

  • 이우철;현동석;이택기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.489-492
    • /
    • 1999
  • This paper proposes a control method for three-phase voltage-source PWM converters using only a single current sensor in the DC link. A predictive current controller for the voltage-source PWM converter is used so that all phase currents can be reconstructed in a switching period although one or two of active vectors are applied only for a short time. Compensation of the 2 step delays is also included. In this paper single sensor current control using predictive state observer will be discussed, and investigated experimentally.

  • PDF

SUDS증발기를 사용한 2중열원 열펌프의 성능해석 (Performance analysis of dual source heat pump system with single unit dual source evaporator)

  • 우정선;이세균;이재효;박효순
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

모델 변수가 EEG의 Single Dipole Source 추정에 끼치는 영향에 관한 연구 (The effect of model parameters on single dipole source tracing in EEG)

  • 박기범;박인호;김동우;배병훈;김수용;박찬영;김신태
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.41-53
    • /
    • 1994
  • 단일 쌍극자 모델을 source localization 문제에 적용시키는 것은 초보적이기도 하지만 필수적이기도 하다. 시abf레이션을 이용하여 단일 쌍극자를 추적함으로써 얻은 결과는 실제 인간의 뇌에 관한 EEG 임상 실험에 여러가지 정보를 제공해줄 수 있기 때문이다. 이번 논문에서는 EEG실험에서의 전극 배치가 S/N(signal to noise ratio)과 추정 오차 사이에 어떤 영향을 미치는 가를 Monte Carlo 시뮬레이션으로 조사하였다. 머리모델은 3중 구각 모델을 사용하였고 이를 이용하여 forward problem을 계산하였다. 쌍극자 파라미터를 minimization하는 문제는 simplex method를 이용하여 계산하였다. 컴퓨터 시뮬레이션 결과, 특이한 점은 전극의 밀도와 입체각에 의해 쌍극자 파라미터 오차가 변화했다는 사실이다. 이것은 곧바로 전극 배치와 연관이 된다. 실제 EEG 실험에서 전극배치를 어떻게 했는가에 따라 그에 따른 오차가 변화한다.

  • PDF

Use of Single-leaf Cutting in the Study of the Expression of Starch Synthesis and Modification Genes in Sweetpotato

  • Kim Sun-Hyung;Hamada Tatsuro;Otani Matoyasu;Koga Hironori;Shimada Takiko
    • Journal of Plant Biotechnology
    • /
    • 제7권2호
    • /
    • pp.123-127
    • /
    • 2005
  • The evaluation of source potential and sink strength is the generally large and laborious sample size required to adequately assess anyone of the parameters in field-grown sweetpotato. For this purpose we used the rooted single-leaf cuttings with petioles, because the source and sink organs are restricted in this system. The rooted single-leaf cutting of sweetpotato provides a unique source-sink model system, and is established within about 50 days after planting. In this study, the sink potential of sweetpotato tubers was examined based on the expression of genes for starch synthesis (AGPase) and modification (SBEII and GBSSI) in single rooted leaf plant. The gene expression patterns of GBSSI, SBEII and AGPase at various developmental stages and in different types of root tissues presented. These results suggest that the rooted single-rooted method can be used an ideal model system to study physiological and biochemical mechanisms in sweetpotato.

전원 전압 왜곡과 주파수 변동 시 단상 PWM 컨버터의 전류 제어 (Current Control of a Single-phase PWM Converter under the Distorted Source Voltage and Frequency Condition)

  • 안창헌;김상훈
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.356-362
    • /
    • 2015
  • This paper presents a current control strategy in the synchronous reference frame for a single-phase PWM converter, which ensures sinusoidal input current control under the distorted source voltage and frequency condition. Given that the distorted source voltage distorts the phase angle for PWM converter control, the input current contains the same harmonics as the source voltage. Aside from the distorted voltage, the variation in source frequency reduces the performance of input current control. To achieve sinusoidal input current control under the distorted source voltage and frequency condition, this paper proposes a compensation strategy of current reference with the distortion component extracted from the phase angle and a detection strategy of frequency variation from the output of a synchronous reference frame phase-lock loop. The experimental results confirm the validity of the proposed method under the distorted source voltage and frequency condition.

슬라이딩 모드 관측기를 이용한 전원전압 센서없는 단상 PWM 컨버터의 고역율 제어 (The Control of Single Phase High Power Factor PWM converter using Siding mode Observer without a source voltage sensor)

  • 유지용;양이우;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.684-687
    • /
    • 1999
  • In this paper, a method for controlling a single phase PWM AC/DC converter without any voltage sensors is proposed. In this method, the source voltage is estimated by sliding mode observer and input current is synchronized with the estimated source voltage. The source voltage is estimated by current error between the actul and the estimated current. The experimental results confirm the validity of the proposed control method.

  • PDF

축소차원 Luenberger 관측기를 이용한 단산 PWM 컨버터의 고역률 제어 (The Control of Single Phase Power Factor PWM converter using Reduced-Order Luenberger Observer)

  • 양이우;이용근;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.485-488
    • /
    • 1999
  • In this paper, a current control system for single phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated source voltage in the controller. The estimation of source voltage is performed by the reduced-order Luenberger observer using actual currents. The estimated source voltage is used to accomplish unity power factor. The proposed method is proved by experiments.

  • PDF