• Title/Summary/Keyword: Single length technique

Search Result 223, Processing Time 0.026 seconds

How to Avoid Graft-Tunnel Length Mismatch in Modified Transtibial Technique for Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Graft

  • Ko, Dukhwan;Kim, Hyeung-June;Oh, Seong-Hak;Kim, Byung-June;Kim, Sung-Jae
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.407-412
    • /
    • 2018
  • Background: We conducted this study to determine the optimal length of patellar and tibial bone blocks for the modified transtibial (TT) technique in anterior cruciate ligament (ACL) reconstruction using the bone-patellar tendon-bone (BPTB) graft. Methods: The current single-center, retrospective study was conducted in a total of 64 patients with an ACL tear who underwent surgery at our medical institution between March 2015 and February 2016. After harvesting the BPTB graft, we measured its length and that of the patellar tendon, patellar bone block, and tibial bone block using the arthroscopic ruler and double-checked measurements using a length gauge. Outcome measures included the length of tibial and femoral tunnels, inter-tunnel distance, length of the BPTB graft, patellar tendon, patellar bone block, and tibial bone block and graft-tunnel length mismatch. The total length of tunnels was defined as the sum of the length of the tibial tunnel, inter-tunnel distance and length of the femoral tunnel. Furthermore, the optimal length of the bone block was calculated as (the total length of tunnels - the length of the patellar tendon) / 2. We analyzed correlations of outcome measures with the height and body mass index of the patients. Results: There were 44 males (68.7%) and 20 females (31.3%) with a mean age of 31.8 years (range, 17 to 65 years). ACL reconstruction was performed on the left knee in 34 patients (53%) and on the right knee in 30 patients (47%). The optimal length of bone block was 21.7 mm (range, 19.5 to 23.5 mm). When the length of femoral tunnel was assumed as 25 mm and 30 mm, the optimal length of bone block was calculated as 19.6 mm (range, 17 to 21.5 mm) and 22.1 mm (range, 19.5 to 24 mm), respectively. On linear regression analysis, patients' height had a significant correlation with the length of tibial tunnel (p = 0.003), inter-tunnel distance (p = 0.014), and length of patellar tendon (p < 0.001). Conclusions: Our results indicate that it would be mandatory to determine the optimal length of tibial tunnel in the modified TT technique for ACL reconstruction using the BPTB graft. Further large-scale, multi-center studies are warranted to establish our results.

Multiplexed single-molecule flow-stretching bead assay for DNA enzymology

  • Lee, Ryanggeun;Yang, Keunsang;Lee, Jong-Bong
    • BMB Reports
    • /
    • v.52 no.10
    • /
    • pp.589-594
    • /
    • 2019
  • Single-molecule techniques have been used successfully to visualize real-time enzymatic activities, revealing transient complex properties and heterogeneity of various biological events. Especially, conventional force spectroscopy including optical tweezers and magnetic tweezers has been widely used to monitor change in DNA length by enzymes with high spatiotemporal resolutions of ~nanometers and ~milliseconds. However, DNA metabolism results from coordination of a number of components during the processes, requiring efficient monitoring of a complex of proteins catalyzing DNA substrates. In this min-review, we will introduce a simple and multiplexed single-molecule assay to detect DNA substrates catalyzed by enzymes with high-throughput data collection. We conclude with a perspective of possible directions that enhance capability of the assay to reveal complex biological events with higher resolution.

Effect of Formation of Segmented Fractures Induced by Fluid Injection on Major Design Parameters (수압파쇄균열의 분할생성 시 주요 설계변수에 대한 영향)

  • Sim, Young-Jong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.125-133
    • /
    • 2009
  • Rock fracturing technique through fluid injection into the wellbore has been widely used to extract geothermal heat and to enhance oil and gas production. Single fracture formation is ideal for the production. However, it is very difficult to form single fracture formation. Instead, the formation of segmented fracture is a common phenomenon. Therefore, design parameters are expected to be different from those of single fracture because of mechanical interaction between segmented fractures. In this paper, design parameters such as length, aperture, and net pressure are evaluated by using model of segmented fracture in which numerical technique is incorporated to consider mechanical interaction between segments. Results show that the existence of fracture segmentation affects design parameters in fracturing treatment in rock by fluid injection.

  • PDF

Effect of Water Flux on the Determination of Membrane Permeability Using Single-pass Perfusion

  • Oh, Doo-Man
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.19-25
    • /
    • 1994
  • The single-pass perfusion technique was employed in order to investigate the effect of water flux from the rat jejunum in the normal experimental conditions. Our results suggested that water flux below ${\pm}0.75%/cm$ of jejunal length was considered normal. Water flux was $-0.131\;{\pm}\;0.311%/cm$ of jejunal length in a citrate buffer and should be corrected in order to determine the permeabilities of the compounds. Perfusion rate up to 0.5 ml/min had no effects on the permeability of ampicillin. Neither the effective permeabilities nor the wall permeabilities of aminopenicillins were influenced by water flux during experiments in rats.

  • PDF

MTA(Memory TestAble) Code for Testing in Semiconductor Memories (반도체 메모리의 테스트를 위한 MTA(Memory TestAble code)코드)

  • 이중호;조상복
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.111-121
    • /
    • 1994
  • This paper proposes a memory testable code called MTA(Memory TestAble) code which is based on error correcting code technique for testing functional faults in semiconductor memories. The characteristics of this code are analyzed and compared with those of conventional codes. The developed decoding technique for this code can reduce the decoder circuits up to 70% and obtain two-times faster decoding speed than other codes such as hamming code or Hsiao code. The MTA code is eccectively applicable to parallel testing of semiconductor memories because it has the same information length and parity length. It can detect from single error functional faults to triple error in semiconductor memories.

  • PDF

Early Outcomes of Single-Port Video-Assisted Thoracic Surgery for Primary Spontaneous Pneumothorax

  • Kang, Do Kyun;Min, Ho Ki;Jun, Hee Jae;Hwang, Youn Ho;Kang, Min-Kyun
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.384-388
    • /
    • 2014
  • Background: Recently, single-port video-assisted thoracic surgery (VATS) has been proposed as an alternative to the conventional three-port VATS for primary spontaneous pneumothorax (PSP). The aim of this study is to evaluate the early outcomes of the single-port VATS for PSP. Methods: VATS was performed for PSP in 52 patients from March 2012 to March 2013. We reviewed the medical records of these 52 patients, retrospectively. Nineteen patients underwent the conventional three-port VATS (three-port group) and 33 patients underwent the single-port VATS (single-port group). Both groups were compared according to the operation time, number of wedge resections, amount of chest tube drainage during the first 24 hours after surgery, length of chest tube drainage, length of hospital stay, postoperative pain score, and postoperative paresthesia. Results: There was no difference in patient characteristics between the two groups. There was no difference in the number of wedge resections, operation time, or amount of drainage between the two groups. The mean lengths of chest tube drainage and hospital stay were shorter in the single-port group than in the three-port group. Further, there was less postoperative pain and paresthesia in the single-port group than in the three-port group. These differences were statistically significant. The mean size of the surgical wound was 2.10 cm (range, 1.6 to 3.0 cm) in the single-port group. Conclusion: Single-port VATS for PSP had many advantages in terms of the lengths of chest tube drainage and hospital stay, postoperative pain, and paresthesia. Single-port VATS is a feasible technique for PSP as an alternative to the conventional three-port VATS in well-selected patients.

Measurement of 3D Flow inside Micro-tube Using Digital Holographic PTV Technique (디지털 Holographic PTV기법을 이용한 미세튜브 내부 3차원 유동장 측정)

  • Kim, Seok;Kim, Ju-Hee;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.177-178
    • /
    • 2006
  • Digital holographic particle tracking velocimetry (HPTV) is developed by single high-speed camera and single continuous laser with long coherent length. This system can directly capture 4000 hologram fringe images for 1 second through a camera computer memory. The 3D particle location is made of the reconstruction by using a computer hologram algorithm. This system can successfully be applied to instantaneous 3D velocity measurement in the water flow inside a micro-tube. The average of 100 instantaneous velocity vectors is obtained by reconstruction and tracking with the time of evolution of recorded fringes images. In the near future, we will apply this technique to measure 3D flow information inside various micro structures.

  • PDF

Spatial Distribution of Localized Charge Carriers in SONOS Memory Cells

  • Kim Byung-Cheul
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.2
    • /
    • pp.84-87
    • /
    • 2006
  • Lateral distributions of locally injected electrons and holes in an oxide-nitride-oxide (ONO) dielectric stack of two different silicon-oxide-nitride-oxide-silicon (SONOS) memory cells are evaluated by single-junction charge pumping technique. Spatial distribution of electrons injected by channel hot electron (CHE) for programming is limited to length of the ONO region in a locally ONO stacked cell, while is spread widely along with channel in a fully ONO stacked cell. Hot-holes generated by band-to-band tunneling for erasing are trapped into the oxide as well as the ONO stack in the locally ONO stacked cell.

Polymeric Wavelength Filter Based on a Bragg Grating Using Nanoimprint Technique (나노 임프린트 기술을 이용한 폴리머 도파로 기반의 브래그 격자형 파장 필터)

  • Ahn, Seh-Won;Lee, Ki-Dong;Kim, Do-Hwan;Chin, Won-Jun;Lee, Sang-Shin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.267-271
    • /
    • 2006
  • A polymeric waveguide-type wavelength filter based on a Bragg grating has been proposed and fabricated using the simple nanoimpring technique, for the first time to our knowledge. An ultraviolet transparent stamp with the single-mode waveguide pattern incorporating a surface-relief-type Bragg grating was specially designed selective dry-etching process. Using this stamp, the device fabrication was substantially involving just a single-step process of imprint followed by polymer spin-coating. The achieved maximum reflection was higher than 25 dB at the center wavelength of 1569 nm. And the 3-dB bandwidth was 0.8 nm for the device length of 1.5 cm.

Optimal Net Residual Dispersion for Compensation of WDM Signals in Dispersion Managed Optical Links with Random Distribution of SMF Length and RDPS (중계 구간의 SMF 길이와 RDPS의 분포가 랜덤한 분산 제어 광전송 링크에서의 WDM 신호의 보상을 위한 최적 전체 잉여 분산)

  • Lee, Seong-Real
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.638-641
    • /
    • 2012
  • Optimal net residual dispersion (NRD) and effective launching power range of optical transmission links with random distribution of single mode fiber (SMF) length and residual dispersion per span (RDPS) required to flexibly design of optical links in dispersion management (DM) technique for compensating the distorted 960 Gbps optical signals due to interaction of group velocoty dispersion (GVD) and optical nonlinear effects are induced.

  • PDF