• 제목/요약/키워드: Single length technique

검색결과 223건 처리시간 0.03초

단일 CNT 팁에서 탄소나노튜브의 에칭부피에 관한 연구 (A Study on the Etched Volume of Carbon Nanotube in the Single CNT Tip)

  • 이준석;최재성;강경수;곽윤근;김수현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1126-1129
    • /
    • 2004
  • Because of the various length condition of carbon nanotube, it is very confined the application area of the single CNT tip. In this paper, it was proposed the cutting technique of single CNT tip and the relationship between the etched volume and the amount of the applied charge. It is possible to control the length of single CNT tip arbitrary using this technique. The etched volume and length in the single CNT tip can be predicted with the amount of the applied charge. It is very easy to make a single CNT tip with proper length using this technique and to make nanotweezer that was composed two single CNT tips.

  • PDF

Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교 (Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file)

  • 임유경;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.385-396
    • /
    • 2007
  • 이 연구의 목적은 Mtwo 전동 파일의 사용에 있어서 제조사가 제안한 single length technique과 crown-down technique의 근관성형효율과 안전성을 비교하고 Mtwo 전동 파일의 변형된 사용방법을 제안하고자 하는 것이다. 기구의 종류와 사용방법에 따라 60개의 레진 블록 근관 모형 (Endo Training Bloc; Benstply Maillefer, Ballaigues, Switzerland)을 세 군으로 나누어 20개씩 표본을 성형하였다. MT군은 Mtwo 파일 (VDW, Munich, Germany)을 제조사의 추천방법인 single length technique으로, MC군은 Mtwo 파일을 crown-down technique으로 형성하였고, 대조군인 PT군은 ProTaper (Denstply Maillefer, Ballaigues, Switzerland)를 사용하였다. 모든 기구는 250 r.p.m., torque 2.2 N로 고정한 전동 모터 (X-smart; Denstply Maillefer, Ballaigues, Switzerland)로 사용하였다. 근관 성형 후, 스캐너로 근관 형성 전후의 이미지를 채득하여 중첩 비교함으로써 근단부로부터 1, 2, 3, 4, 5, 6, 7, 8 mm 높이에서의 중심변위율을 산출하였다. 순수 기구조작 시간 및 기구조작 동안의 binding빈도를 기록하였다. 근관 성형 후, 레진 블록의 무게 감소를 측정하였고 근관 성형에 사용된 파일의 파절이나 변형 및 근관 성형 후 형태의 이상을 조사하였다. 세 실험군의 측정 및 산출된 자료를 일원배치 분산분석 및 Duncan's Multiple Range Test로 사후 검정을 시행하여 비교하였으며, Fisher's exact test으로 근관의 이형성, 기구의 변형 그리고 기구 binding 등 발생 빈도를 유의 확률 95%에서 통계 검정하였다. 그 결과는 다음과 같다. 1. 근관의 만곡도 감소, 중심변위율, 레진 블록의 무게 감소, 기구 변형 등은 세 군간에 유의한 차이가 없었다 (p > 0.05). 2. 기구 조작 시간은 보면 MT군과 MC군이 PT군보다 짧았다 (p < 0.05). 3. Elbow는 MT군이 MC군에서 PT군보다 더 많이 형성되었다 (p < 0.05). Ledge는 세 군 모두에서 나타나지 않았다. 4. 파일 binding 횟수는 MC군이 가장 적고 PT군이 가장 많았다 (p < 0.05). 이상의 결과를 볼 때, Mtwo 전동 파일을 crown-down technique으로 사용하는 것이 single length technique과 유사한 성형 효율을 보이면서도 더 안전할 것으로 추정된다.

Effect of link length in retrofitted RC frames with Y eccentrically braced frame

  • INCE, Gulhan
    • Steel and Composite Structures
    • /
    • 제43권5호
    • /
    • pp.553-564
    • /
    • 2022
  • Many existing reinforced concrete (RC) structures need to be strengthening for reason such as poor construction quality, low ductility or designing without considering seismic effects. One of the strengthening methods is strengthening technique with eccentrically braced frames (EBFs). The characteristic element of these systems is the link element and its length is very important in terms of seismic behavior. The link element of Y shaped EBF systems (YEBFs) is designed as a short shear element. Different limits are suggested in the literature for the link length. This study to aim experimentally investigate the effect of the link length for the suggested limits on the behavior of the RC frame system and efficiency of strengthening technique. For this purpose, a total of 5 single story, single span RC frame specimens were produced. The design of the RC frames was made considering seismic design deficiencies. Four of the produced specimens were strengthened and one of them remained as bare specimen. The steel YEBFs were used in strengthening the RC frame and the link was designed as a shear element that have different length with respect to suggested limits in literature. The length of links was determined as 50mm, 100mm, 150mm and 200mm. All of the specimens were tested under cyclic loads. The obtained results show that the strengthening technique improved the energy consumption and lateral load bearing capacities of the bare RC specimen. Moreover, it is concluded that the specimens YB-2 and YB-3 showed better performance than the other specimens, especially in energy consumption and ductility.

Crystal growth of yttrium vanadate by the EFG technique

  • Kochurikhin, V.V.;Ivanov, M.A.;Suh, S.J.;Yoon, D.H.
    • 한국결정성장학회지
    • /
    • 제11권5호
    • /
    • pp.203-206
    • /
    • 2001
  • The applicability of shaped growth of yttrium orthovanadate was approved by successful growth of rod-like single crystals with the rectangular shape. Nd-doped single crystals with content of $Nd^{3+}$ ions of 1,2,3,5 atomic % in the starting melt were grown by the EFG technique with the size up to $10^{*}10mm$ in section and up to 85 mm in length. For the testing of the multiple growth of the orthovanadates, two and three Nd-and Yb-doped $YVO_{4}$ single crystals were grown by the EFG technique simultaneously up to 110 mm in length.

  • PDF

Spatial Distribution of Injected Charge Carriers in SONOS Memory Cells

  • Kim Byung-Cheul;Seob Sun-Ae
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.894-897
    • /
    • 2006
  • Spatial distribution of injected electrons and holes is evaluated by using single-junction charge pumping technique in SONOS(Poly-silicon/Oxide/Nitride/Oxide/Silicon) memory cells. Injected electron are limited to length of ONO(Oxide/Nitride/oxide) region in locally ONO stacked cell, while are spread widely along with channel in fully ONO stacked cell. Hot-holes are trapped into the oxide as well as the ONO stack in locally ONO stacked cell.

  • PDF

DNA damage와 Apoptosis를 정량화하는 단세포전기영동법 (Single Cell Gel Electrophoresis (comet assay) to Detect DNA Damage and Apoptosis in Cell Level)

  • 류재천;김현주;서영록;김경란
    • 한국환경성돌연변이발암원학회지
    • /
    • 제17권2호
    • /
    • pp.71-77
    • /
    • 1997
  • The single cell gel electrophoressis(SCGE) assay, also known as the comet assay, is a rapid, simple, visual and sensitive technique for measuring and analysing DNA breakage in mammalian cells. The SCGE or comet assay is a promising test for the detection of DNA damage and repair in individnal cells. It has widespread potential applications in DNA damage and repair studies, genotoxicity testing and biomonitoring. In this microgel electrophoresis technique, cells are embedded in agarose gel on microscope slides, iysed and electrophoresed under alkaline conditions. Cells with increased DNA damage display increased migration of DNA from the nucleus towards the anode. The length of DNA migration indicates the amount of DNA breakage in the cell. The comet assay is also capable of identifying apoptotic cells which contain highly fragmented DNA. Here we review the development of the SCGE assay, existing protocols for the detection and analysis of comets, the relevant underlying principles determining the behaviour of DNA and the potential applications of the technique.

  • PDF

근광장 측정에서 방사선 사진술의 정확도 (The Accuracy of the Radiographic Method in Root Canal Length Measurement)

  • 조은영;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics

  • Hung, Bui Quang;Hong, Mihee;Yu, Wonjae;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제50권1호
    • /
    • pp.26-32
    • /
    • 2020
  • Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.

단일겹침 접착제 접합부의 응력분포와 강도평가 (Stress Distribution and Strength Evaluation of Adhesive Bonded Single-lap Joints)

  • 이중삼;임재규;김연직
    • Journal of Welding and Joining
    • /
    • 제19권3호
    • /
    • pp.342-347
    • /
    • 2001
  • Recently, adhesive-bonding technique is wifely used in manufacturing structures. Stress and strain analysis of joints are essential to design adhesive-bonded joints structure. The single-lap adhesive joint is the design dominating the range of adhesive joints. In this study, single-lap specimens with different joint dimensions were used for the tensile-shear test and finite element calculation in of order to investigate the effect of overlap length and adhesive-bonding thickness on adhesive strength and stress distribution of the joints. Consequently, it was found that overlap lap size and thickness can be important parameters of structure joints using adhesive bonding, which is effected on adhesive strength.

  • PDF

대중교통 지선노선 선정기법에 관한 연구 (A Study on the Feeder Transit Route Choice Technique)

  • 배기목
    • 한국항해항만학회지
    • /
    • 제27권4호
    • /
    • pp.479-484
    • /
    • 2003
  • 지선버스 노선선정의 경우, 전체 네트워크로서의 노선선정 보다는 지하철 역 등의 특정 기ㆍ종점과의 연계차원에서 단일 노선으로 취급하여 노선선정을 행함이 바람직하다. 본 연구에서는 이와 같은 관점 하에 정류장 대기시간, 환승시간 등은 고려하지 않고, 일정 기ㆍ종점을 연결하는 지선노선 선정을 위한 간편 기법을 구축하였다. 검토대상 도로망 한정, 허용노선장에 의한 후보노선의 열거, 노선평가치에 의한 최종 노선의 선정 등의 3가지 단계를 통해 지선기능으로서의 마을버스 노선을 선정하는 기법을 구축하였다.