• 제목/요약/키워드: Single implant crown

검색결과 51건 처리시간 0.02초

상악 전치부 임플란트지지 수복금관의 주변 연조직 제원 변화에 관한 누년적 연구 (Alterations of the soft tissue dimensions around implant-supported singletooth replacements in the maxillary anterior region - A retrospective longitudinal study -)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제28권3호
    • /
    • pp.507-517
    • /
    • 1998
  • This study was performed to investigate the soft tissue changes around single implant-supported crowns during followup periods. Twenty patients(31 implants) whose single missing tooth in the maxillary anterior region had been replaced with an single implant-supported crown were recruited for the study. Crown length, soft tissue level and papilla height at the single implant-supported crowns were measured at follow-up examination and calculated from the slides taken at time of crown placement. as well Papilla index was scored from the slides taken at the time of crown placement and follow-up examination. A very little amount of recession occurred and the soft tissue level moved more apically and the papilla height increased significantly (p<0.01). Especially, both mesial and distal papilla index at single implant-supported crowns increased significantly during follow-up periods (p<0.001). When the two slides taken at the time of crown placement and follow-up were compared simultaneously, except one site, papillae size increased at all sites. From the results of the study, the interdental papillae at the single implant-supported crowns seemed to regenerate significantly and their crown margins were stable during follow-up periods. Hence it is indicated that various surgical interventions at on early stage to enhance soft tissue esthetics arourd single implants may be unnecessary.

  • PDF

상악 전치부 단일 임플란트 지지 수복금관의 주변 연조직반응의 단면적 연구 (Soft tissue reactions around implant-supported single-tooth replacements in the maxillary anterior region)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.321-337
    • /
    • 1998
  • The aims of this study were firstly to investigate soft tissue reactions around single implant-supported crowns and secondly to compare soft tissue dimensions and conditions of the crowns in relation to interdental papillae, and lastly to investigate patients'esthetic satisfaction with their single implant-supported crowns according to the interdental papillae presence/absence. Twenty-nine patients (41 implants) whose single missing tooth in the maxillary anterior region had been replaced by single implant-supported crown participated for the study and various variables of soft tissue conditions, dimensions and crown dimensions were measured around the single implant-supported crowns at clinical examination and from study models and slides. The results showed that the soft tissue conditions around the single implantsupported crowns were similar to those around implants used for partially or totolly edentulous patients. Except for the high frequency of bleeding on probing, all other parameters revealed healthy conditions. The buccal sites of the crown had a shallow pocket comparing with other sites. At all sites of the crown, similar status of little inflammation was found. Mesial sites and central-incisor positioned implantsupported crowns had lower contact point position than distal sites and lateral-incisor positioned crowns, respectively. Mucositis index, probing depth and contact point position were significantly correlated with papillae index(p < 0.05). More inflammation and lower contact point position were found at the implant-supported crown with no interdental space than that with interdental space. Patients showed high esthetic satisfaction regardless of interdental space presence. The result indicated that, despite of their submucosal crown margins, single implantsupported crowns have soft tissue conditions as good as other implants used for the treatment of the different types of edentulism and a clinician can manipulate interdental papilla height by modifying crown shapes within the limits of not violating total esthetics.

  • PDF

콤비네이션 임프란트 크라운(Combination Implant Crown)을 이용한 단일치아의 임프란트 보철수복증례 (SINGLE TOOTH IMPLANT RESTORATION USING COMBINATION IMPLANT CROWN : A CASE REPORT)

  • 김래경;송언희;최병갑;김현철;안현정
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.375-382
    • /
    • 1999
  • The purpose of this article is to present the clinical and laboratory procedures for single tooth restoration using 'Combination Implant Crown'. It is cemented on implant abutment and that abutment is screw-retained over implant body. This type of implant restorations has the advantages of cement-retained restoration while being antirotational and retrievable. And, more esthetic and functional result can be achieved by minimizing the size of access hole. The results were as follows : 1. Preparation of abutment below the cuff line should be avoided 2. Axial reduction of implant abutment should not be excessive because it may weaken the abutment 3. More esthetical and functional occlusal surface was achieved with a minimal access hole which is slightly larger than the diameter of hex driver to enable future total retrievability. 4. Combination Implant Crown has the advantages of both the cement-retained and screw-retained type implant restoration. 5. Cementation between implant crown and abutment reduces screw loosening through even force distribution

  • PDF

Transitional implant를 이용한 임시수복과 최종 수복 (CLINICAL APPLICATION OF TRANSITIONAL IMPLANTS)

  • 김유리;민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권6호
    • /
    • pp.575-580
    • /
    • 2005
  • Transitional implants were developed to support provisional restorations and to allow for load-free osseointegration of conventional implants while a patient was provided with immediate esthetics and function and are usually placed simultaneously at the time of definitive implant placement. Transitional implants are placed in a non-submerged fashion in a single-stage surgery and are designed to be immediately loaded. They generally are made of commercially pure titanium or titanium alloy and are designed as 1-piece implants composed of root and crown replacement segments. Transitional implants can be used in a wide range of indications, such as basic use as temporary implant, to support and protect the primary implants during the healing phase, single crown in the edentulous anterior region of mandibular, anchorage for orthodontic treatment, support a surgical and radiographic template, and primary implant to extremely atrophied alveolar crests of the mandible and maxilla. This article describes the clinical use of transitional implants to support the provisional complete denture and single crown in the restricted edenturous central incisor region of mandible.

하악구치 임플란트 지지 단일수복에서 근심 캔틸레버가 임플란트 합병증에 미치는 영향 (COMPLICATIONS OF THE IMPLANT-SUPPORTED POSTERIOR MANDIBULAR SINGLE RESTORATIONS WITH MESIAL CANTILEVER)

  • 신혜승;김명래;김선종
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권4호
    • /
    • pp.248-252
    • /
    • 2009
  • Purpose: This retrospective study was performed to analyze the relationship between complications of the posterior mandibular single crowns and distance from the adjacent teeth to the implant. Subjects and Methods: Of the patients who presented Ewha Womans University Mokdong Hospital & Yonsei University Dental Hospital with missing of the posterior mandibular molar and restored with implant-supported 18 Single crowns between 1996 thru 2007, 115 patients had been followed after crown delivery. The subjects were divided into complication-followed group and a control without any problems. The distance from the most distal tooth to the implant were measured. The prosthetic & biologic complications were reviewed by the cantilever distance and analyzed by abutment type, age & gender statistically using SAS version 9.1 (SAS Inc., USA). Results and Conclusion The results were as follows; 1) The posterior mandibular single crown with cantilever showed higher incidence of follow-up complications upon logistic analysis (p<0.05). 2) The prosthetic and biologic complications are related with the cantilever distance with 2.1 odds ratio and 3.39 cut-off value of specificity & sensitivity by SPSS 12.0. 3) The complications are neither significant in abutment types nor age & gender.

심미적 영역에서 즉시 임플란트 식립 및 임시 수복을 통한 단일치의 수복에 대한 증례 보고 (Immediate implant placement and provisionalization of single implant in the esthetic region : Cases report)

  • 이성배;박유선;김병헌;이보아;최성호;김영택
    • 대한치과의사협회지
    • /
    • 제58권2호
    • /
    • pp.83-92
    • /
    • 2020
  • In the anterior maxillary area, dental implants for tooth replacement are challenging due to the need to satisfy high esthetic level as well as functionality. Immediate implant placement and provisionalization can dramatically reduce the edentulous period, and then fulfill patient's demand for esthetics. The aim of present case report is to demonstrate two cases that successfully restored single tooth with immediate implant placement and provisionalization in the anterior maxillary area. A 47 years old female was scheduled to replace her maxillary right central incisor due to crown-root fracture by trauma. Another 54-year-old female was planned to place dental implant following tooth extraction of maxillary right lateral incisor owing to continuous pus discharge despite repetitive treatments including apicoectomy. In these two cases, surgical and prosthetic procedures progressed in a similar way. After minimal flap elevation, atraumatic tooth extraction was performed. Implant was placed in proper 3-dimensional position and angulation with primary stability. Bone graft or guided bone regeneration for peri-implant bone defect was conducted simultaneously. Provisionalization without occlusal loading was carried out at the same day. Each definitive crown was delivered at 7 and 5 months after the surgery. Two cases have been followed uneventfully for 2 to 5 years of loading time. In conclusion, Immediate implant placement and provisionalization could lead to esthetic outcome for single tooth replacement with dental implant under proper case selection.

  • PDF

수복재료와 임플랜트 종류에 따른 임플랜트 및 지지조직의 응력분포 (THE STRESS ANALYSIS OF SUPPORTING TISSUE AND IMPLANT ACCORDING TO CROWN RESTORATIVE MATERIALS AND TYPE OF IMPLANT)

  • 최창환;오종석;방몽숙
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.53-67
    • /
    • 2002
  • This study was aimed to analyze the stress distribution of implant and supporting tissue in single tooth implant restoration using Branemark $system^{(R)}$(Nobel Biocare, Gothenberg, Sweden) and Bicon system(Bicon Dental Implants, Boston, MA). Two dimensional finite element analysis model was made at mandibular first premolar area As a crown materials porcelain, ceromer, ADA type III gold alloy were used. Tests have been performed at 25Kgf vertical load on central fossa of crown portion and at 10Kgf load with $45^{\circ}$ lateral direction on cusp inclination. The displacement and stresses of implant and supporting structures were analyzed to investigate the influence of the crown material and the type of implant systems by finite element analysis. The results were obtained as follows : 1. The type of crown material influenced the stress distribution of superstructure, but did not influence that of the supporting alveolar bone. 2. The stress distribution of ceromer and type III gold alloy and porcelain is similar. 3. Stress under lateral load was about twice higher than that of vertical load in all occlusal restorative materials. 4. In Bicon system, stress concentration is similar in supporting bone area but CerOne system generated about 1.5times eater stress more in superstructure material. 5. In Branemark models, if severe occlusal overload is loaded in superstvucture. gold screw or abutment will be fractured or loosened to buffer the occlusal overload but in Bicon models such buffering effect is not expected, so in Bicon model, load can be concentrated in alveolar bone area.

하중 위치에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분석 (Finite element analysis of stress distribution on supporting bone of cement retained implant by loading location)

  • 김갑진
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.143-149
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the effect of two different oblique mechanical loading to occlusal surfaces of cement retained implant on the stress distributions in surrounding bone, using 3-dimensional finite element method. Methods: A 3-dimensional finite element model of a cement retained implant composed of three unit implants, simplified ceramic crown and supporting bone was developed according to the design of ement retained implant for this study. two kinds of surface distributed oblique loads(100 N) are applied to following occlusal surfaces in the single crowns; 1) oblique load on 2 occlusal points(50N for each buccal cusp, 2 buccal cusps exist), 2) oblique load on 4 occlusal points(25N for each buccal and lingual cusp, 2 buccal and 2 lingual cusps exist) Results: The results of the comparison of the stress distributions on surrounding bone are as follows. In the condition of oblique load on 2 occlusal points, VMS was 741.3 Mpa in the M1(Ø$4.0{\times}13mm$) model and 251.2 Mpa in the M2(Ø$5.0{\times}13mm$) model. It means the stress on the supporting bone is decreased. The results of oblique load on 4 occlusal points are similar to this one. Conclusion: Increasing the diameter of the implant fixture is helpful to distribute the stress on the supporting bone. Also, to obtain the structural stability of the supporting bone, it is effective to distribute the load evenly on the occlusal surface of crown in producing single crown implant.

하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향 (Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant)

  • 백연화;김봉주;김명주;권호범;임영준
    • 구강회복응용과학지
    • /
    • 제34권4호
    • /
    • pp.280-289
    • /
    • 2018
  • 목적: 이 연구의 목적은 임플란트의 길이 및 치관-임플란트 비율(crown-to-implant (C/I) ratio)이 임플란트의 안정성과 임플란트 변연골 소실량(MBL)에 영향을 주는지 알아보기 위함이다. 연구 재료 및 방법: 연구대상자로 하악 구치부에 단일치를 상실한 46명의 환자를 선별하였다. 대조군에는 총 19개의 직경 5.0 mm, 길이 10 mm의 임플란트(CMI IS-III $active^{(R)}$ long implant)를 식립하였고, 실험군에는 직경 5.5 mm, 길이 6.6, 7.3, 8.5 mm의 임플란트 총 27개(CMI IS-III $active^{(R)}$ short implant)를 식립하였다. 각각의 임플란트는 디지털 방식으로 술 전 제작한 수술가이드를 사용하여 식립하였고 임시보철물을 장착하여 즉시부하를 시행하였다. 술 후 3개월에 CAD-CAM 방식으로 제작한 지르코니아 크라운으로 최종 수복하였다. 술 후 48주에 ISQ 값과 변연골 소실량을 측정하여 치관-임플란트 비율과 ISQ 및 변연골 소실량 간의 상관관계를 비교하였다. 결과: 두 그룹 모두 안정도 및 변연골 소실량 면에서 성공적인 결과를 나타내었다. 술 후 48주에 측정한 두 그룹간 ISQ와 변연골 소실량 값은 통계적으로 유의미한 차이가 없었다(P > 0.05). 치관-임플란트 비율과 안정성 및 치관-임플란트 비율과 변연골 소실량 간에 어떤 상관관계도 관찰되지 않았다(P > 0.05). 결론: 두 그룹의 하악 단일 임플란트에서 치관-임플란트 비율은 안정성 및 변연골 소실량에 영향을 주지 않는 것으로 나타났다. 골높이가 부족한 하악에서 단일 임플란트 수복 시, 짧은 임플란트는 상대적으로 높은 치관-임플란트 비율에도 불구하고 제한된 조건 하에서 적절한 대안이 될 수 있다.

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.