1 |
Malevez C, Hermans M, Daelemans P: Marginal bone levels at Branemark system implants used for single tooth restoration: the influence of implant design and anatomical region, Clin Oral Implants Res 1996;7:162-9
DOI
ScienceOn
|
2 |
Maeda Y. Satoh T. & Sogo M. In vitro differences of stress concentrations for internal and external hex implant?abutment connections: a short communication Pact Periodontics Aesthet Dent. 1998 Nov-Dec;10(9):1131-41
DOI
ScienceOn
|
3 |
Adell R, Lekholm U, Rockler B, Branemark PI, Lindhe J, Eriksson B, Sbordone L: Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study, Int J Oral Maxillofac Surg. 1986 Feb;15(1):39-52
DOI
|
4 |
Dykema RW, Goodacre CJ, Phillips RW. Johnston's Modern Practice in Crownand Bridge Prosthodontics. Philadelphia: W.B. Saunders Co.,1986;24-36
|
5 |
Sullivan DY: Wide implants for wide teeth, Dent Econ 1994;84: 82-3
PUBMED
|
6 |
Rangert B, Krogh PH, Langer B, et al: Bending overlad and fixture facture: a retrospective clinical analysis, Int J Oral Maxillofac Implants 1995;10:326-34
|
7 |
Khraisat A, Stegaroiu R, Nomura S, Miyakawa O. Fatigue resistance of two implant/abutment joint designs. J Prosthet Dent. 2002;88:604-10
DOI
ScienceOn
|
8 |
Merz BR, Hunenbart S, Belser UC. Mechanics of the implantabutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants. 2000;15:519-26
|
9 |
Rangert B, Krogh PH, Langer B, et al: Bending overload and implant failure: a retrospective clinical analysis, Int J Oral Maxillofac Implants 1995;7:40-4
|
10 |
Walton JN, Gardner FM, Agar JR: A survey of crown and fixed partial denture failures, length of service and reasons for replacement, J Prosthet Dent 1986;56:416-21
DOI
ScienceOn
|
11 |
Adell R, Lekholm U, Rockler B, Branemark PI.: A 15-year study of osseointegrated implants in the treatment of the edentulous jaw, Int J Oral Surg. 1981 Dec;10(6):387-416
DOI
PUBMED
|
12 |
Naert I, Quirynen M, van Steenberghe D, et al: A six year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism, J Prosthet Dent 1992;67: 236-45
DOI
ScienceOn
|
13 |
Salama H, Salama MA, Garber D, Adar P.: The interproximal height of bone: a guidepost to predictable aesthetic strategies and soft tissue contours in anterior tooth replacement, Pr
|
14 |
Mollersten L, Lockowandt P, Linden LA.: Comparison of strength and failure mode of seven implant systems: an in vitro test, J Prosthet Dent. 1997 Dec;78 (6):582-91
DOI
ScienceOn
|
15 |
Br¨agger U, Aeschlimann S, Burgin W, Hammerle CH, Lang NP. Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clin Oral Implants Res. 2001 Feb;12(1):26-34. Lang NP
DOI
ScienceOn
|
16 |
Schwartz NL, Whitsett LD, Berry TG: Unserviceable crowns and fixed partial dentures: life span and causes for loss of serviceability, J Am Dent Assoc 1970;81:1395-401
DOI
PUBMED
|
17 |
Quirynen M, Naert I, van Steenberghe D: Fixture design and overload influence marginal bone loss and fixture success in the Branemark system, Clin Oral Implants Res 1992;3:104-11
DOI
ScienceOn
|
18 |
Jemt T, Linden B, Lekholm U: Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual check up, Int J Oral Maxillofac Implants 1992;7:40-4
|
19 |
Norton MR: An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design, Clin Oral Implants Res. 1997 Aug;8(4):290-8
DOI
ScienceOn
|