• 제목/요약/키워드: Single component

검색결과 1,270건 처리시간 0.03초

단상 유도전동기의 속도제어 시스템 (Speed Control System of Single Phase Induction Motor)

  • 이득기;이경주;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권5호
    • /
    • pp.229-237
    • /
    • 2001
  • Until recent years, most of the researches for motor drives focus on the high performance drive of the three phase induction motor, and that of the single phase induction motor(SPIM) is out of interest. The SPIM is widely used at low power level because it has the simple construction and economic advantage. In general such machine has both main winding and auxiliary winding. Conventionally, these winding are fed by only one single phase source, and the speed of the motor is not controlled. The SPIM with an auxiliary winding can be treated as an asymmetrical two phase machine. In this paper the space vector Equivalent circuit of SPIM is derived. For vector control of the SPIM the stator current must be decoupled into the flux producing component and the torque producing component. To accomplish decoupling control, the conventional method requires complex calculation and large computation time. We proposed the equivalent circuit referred to the rotor side, in this case only the stator resistances in the direct axis and the quadrature axis are different each other and the other parameters are represented to be equal. Thus the decoupling of the stator current is similar to that of the three phase induction motor. In this paper, the novel vector control system of the single phase induction motor is proposed. To verify the feasibility of this scheme, simulation and experimentation are carried out. The results prove the excellent characteristics for the dynamic response, which confirms the validity of the proposed system.

  • PDF

SRF-PLL을 이용한 계통연계형 단상 인버터의 전원 위상각 검출시 옵셋 오차 영향에 관한 연구 (A Study on Effects of Offset Error during Phase Angle Detection in Grid-tied Single-phase Inverters based on SRF-PLL)

  • 권영;성의석;황선환
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.73-82
    • /
    • 2015
  • This paper proposes an ripple reduction algorithm and analyzes the effects of offset and scale errors generated by voltage sensor while measuring grid voltage in grid-tied single-phase inverters. Generally, the grid-connected inverter needs to detect the phase angle information by measuring grid voltage for synchronization, so that the single-phase inverter can be accurately driven based on estimated phase angle information. However, offset and scale errors are inevitably generated owing to the non-linear characteristics of voltage sensor and these errors affect that the phase angle includes 1st harmonic component under using SRF-PLL(Synchronous Reference Frame - Phase Locked Loop) system for detecting grid phase angle. Also, the performance of the overall system is degraded from the distorted phase angle including the specific harmonic component. As a result, in this paper, offset and scale error due to the voltage sensor in single-phase grid connected inverter under SRF-PLL is analyzed in detail and proportional resonant controller is used to reduce the ripples caused by the offset error. Especially, the integrator output of PI(Proportional Integral) controller in SRF-PLL is selected as an input signal of the proportional resonant controller. Simulation and experiment are performed to verify the effectiveness of the proposed algorithm.

커패시터 구동형 단상유도전동기의 손실분리에 대한 연구 (Study on Losses Segregation for Capacitor-Run Single Phase Induction Motor)

  • 김광수;김기찬;이성구;고성철;전연도;이철규;이주
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1546-1551
    • /
    • 2008
  • This paper is concerned with the problems of accurate losses segregation in capacitor-run single phase motor. Segregation of losses in single phase induction motor is more complicated than that in three phase induction motor, because of the backward magnetic field component in the motor. Generally there are two methods for losses segregation of single phase induction motor. The one is relatively complicated method based on parameter estimation of single phase induction motor. By the way, the other one is simplified method based on IEEE Standard 114. All of the methods for the experimental determination of single phase induction motor losses are studied in this paper. Since the IEEE Standard is not possible to be applied for all type of single phase induction motors, we modified that method to apply for losses segregation of capacitor-run single phase induction motor as unifying the method based on parameter estimation.

미세 구조 변화에 따른 ZnS 세라믹의 중적외선 투과 특성 연구 (A Study of Middle Infrared Transparent Properties of ZnS Ceramics by the Change of Micro Structure)

  • 박창순;여서영;권태형;박운익;윤지선;정영훈;홍연우;조정호;백종후
    • 한국전기전자재료학회논문지
    • /
    • 제30권11호
    • /
    • pp.722-727
    • /
    • 2017
  • Transparent ZnS ceramics were synthesized by hydrothermal synthesis ($180^{\circ}C$ for 70 h), and were sintered by a hot press process at $950^{\circ}C$. To confirm the optical properties of the ZnS ceramics after sintering for various sintering holding times, we performed X-ray diffraction analysis, scanning electron microscopy, and Fourier-transform-infrared spectroscopy. The ZnS nanopowders was found to be single-phase (cubic) without any hexagonal phase. However, the hexagonal phase is formed and increases in content with increasing sintering holding time. The density of the ZnS ceramics was above 99.7%, except for the unsintered one. The ZnS ceramics showed high transmittance (~70%) when sintered for more than 2 h.

Influence of multi-component ground motions on seismic responses of long-span transmission tower-line system: An experimental study

  • Tian, Li;Ma, Ruisheng;Qiu, Canxing;Xin, Aiqiang;Pan, Haiyang;Guo, Wei
    • Earthquakes and Structures
    • /
    • 제15권6호
    • /
    • pp.583-593
    • /
    • 2018
  • Seismic performance is particularly important for life-line structures, especially for long-span transmission tower line system subjected to multi-component ground motions. However, the influence of multi-component seismic loads and the coupling effect between supporting towers and transmission lines are not taken into consideration in the current seismic design specifications. In this research, shake table tests are conducted to investigate the performance of long-span transmission tower-line system under multi-component seismic excitations. For reproducing the genuine structural responses, the reduced-scale experimental model of the prototype is designed and constructed based on the Buckingham's theorem. And three commonly used seismic records are selected as the input ground motions according to the site soil condition of supporting towers. In order to compare the experimental results, the dynamic responses of transmission tower-line system subjected to single-component and two-component ground motions are also studied using shake table tests. Furthermore, an empirical model is proposed to evaluate the acceleration and member stress responses of transmission tower-line system subjected to multi-component ground motions. The results demonstrate that the ground motions with multi-components can amplify the dynamic response of transmission tower-line system, and transmission lines have a significant influence on the structural response and should not be neglected in seismic analysis. The experimental results can provide a reference for the seismic design and analysis of long-span transmission tower-line system subjected to multi-component ground motions.

단상 계통연계형 태양광 발전시스템의 맥동전압제거 기법 (The Elimination Method of Ripple Voltage for a Single Grid-Connected PV System)

  • 이재근;최종우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.406-407
    • /
    • 2011
  • The dc link voltage in a single-phase PV system has necessarily twice component of fundamental wave. It makes high THD in the grid current, and according to the problem, power quality is lower. This paper proposes the new method for removing ripple voltage. The performance was verified through computer simulation using MATLAB.

  • PDF

Periodic domain formation in $>LiNbO_3$ single crystals during growth

  • Park, Jong-Koen
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1998년도 PROCEEDINGS OF THE 14TH KACG TECHNICAL MEETING AND THE 5TH KOREA-JAPAN EMGS (ELECTRONIC MATERIALS GROWTH SYMPOSIUM)
    • /
    • pp.23-26
    • /
    • 1998
  • The domain formation phenomena of {{{{ { LiLbO}_{ 3} }}}} crystals was investigated and the method for the periodic domain formation in {{{{ { LiLbO}_{ 3} }}}} single crystals during growth was proposed in this study. The strees-induced domain formation mechanism was proposed and explained. The strong piezoelectric effect of{{{{ { LiLbO}_{ 3} }}}} at elevated temperature would be the direct driving force for the inversion of the tensile component of the internal stresses can inverse the original direction of the spontaneous polarization.

  • PDF

하모닉 직교 방식의 초음파 고조파 영상화 기법 (Ultrasound Harmonic Imaging Method based on Harmonic Quadrature Demodulation)

  • 김상민;송재희;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권1호
    • /
    • pp.79-88
    • /
    • 2009
  • A harmonic quadrature demodulation method to extract the second harmonic component from focused ultrasound signals after a single transmit-receive event is proposed. In the proposed method, the focused ultrasound signal is converted into baseband inphase and quadrature components by multiplying with sine and cosine signals both having twice the center frequency of the transmitted signal and filtering the two modulated signals. The quadrature component is then passed through a Hilbert filter to be added to the inphase component, which leaves only the envelope of the second harmonic component. A novel phase estimation technique is employed in the proposed method to avoid the phase mismatch between the focused signal and the two modulating signals. The proposed method is verified through both theoretical analysis and computer simulations. It is shown that compared to the pulse inversion scheme the proposed method provides almost the same results for stationary targets and significantly improved harmonic to fundamental ratio for moving targets.

산화전분 코팅에 의한 골판지 상자의 물성 변화 (Effect of Coating of Liner Components with Oxidized Starch on Properties of Corrugated Box)

  • 안병국;안원영
    • 펄프종이기술
    • /
    • 제31권3호
    • /
    • pp.47-53
    • /
    • 1999
  • The effect of coating of liner components with oxidized starch on the properties of corrugated box was examined . Coating was carried out on liner components of B flute, single-wall corrugated board(SK180/S120/K200) , and corrugated box was made from the treated corrugated board. Box was made in a regular slotted container (RSC) style, and box compression strength was determined in the direction of top-to-bottom compression. The compression strength of box coated on outside liner component showed 15.4% improvement for 1.58g㎡ coating. On the other hand, the strength of box coated on outside liner component showed only 1.45% improvement for 1.41g/㎡ coating and 3.46% improvement for 2.32g/㎡ coating. Coating on inside liner component with oxidized starch at low coating weight more significantly improved box compression strength than coating on outside liner component, and the improvement was marked at the coating weight of 1.5-2.5g/㎡. In estimating top-to-bottom box compression strength, the experimental values were closer to the calculated values from McKee's equation suing edgewise compression strength of the combined board measured by column crush test than those from Kellicutt's equation using compression strength of component paperboards measured by ring crush test.

  • PDF

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법의 실험적 고찰 (Experimental Study of Second Harmonic Ultrasound imaging with a Weighted Chirp Signal)

  • 김동열;이종철;송태경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.151-154
    • /
    • 2001
  • In this Paper, a new harmonic imaging technique is proposed and evaluated experimentally. In the proposed method, a weighted chin signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic (2f0) component of a transmitted chirp signal generated in a square-law system. The proposed method uses the compressed 2f0 component to form an image, for which the crosscorrelation term with f0 component should be suppressed below at least -60dB. After experiment, the 6dB pulse width and peak sidelobe level of the compressed 2f0 component were 0.7us and -60dB, respectively. This result shows that the proposed method can successfully eliminate the f0 component with a single transmit-receive event and therefore is more efficient than the conventional pulse inversion (PI) method in terms of frame rate. We also observed that the 2nd harmonic compont starts to decrease for source pressure higher than 210kPa in water, which implies that SNR of the 2nd harmonic imaging using short pulses cnanot be incresed beyond a certain limit.

  • PDF