Influence of multi-component ground motions on seismic responses of long-span transmission tower-line system: An experimental study |
Tian, Li
(School of Civil Engineering, Shandong University)
Ma, Ruisheng (School of Civil Engineering, Shandong University) Qiu, Canxing (School of Civil Engineering, Shandong University) Xin, Aiqiang (School of Civil Engineering, Shandong University) Pan, Haiyang (School of Civil Engineering, Shandong University) Guo, Wei (School of Civil Engineering, Central South University) |
1 | Bai, F.L., Hao, H., Bi, K.M. and Li, H.N. (2011), "Seismic response analysis of transmission tower-line system on a heterogeneous site to multi-component spatial ground motions", Adv. Struct. Eng., 286(3), 565-585. |
2 | GB 18306-2015 (2015), Seismic Ground Motion Parameters Zonation Map of China, Standardization Administration of China Press, Beijing, China. |
3 | GB 50260-2013 (2013), Code for Seismic Design of Electrical Installations, China Architecture & Building Press, Beijing, China. |
4 | Ghobarah, A. and Aziz, T.S. (1996), "El-Attar M. response of transmission lines to multiple support excitation", Eng. Struct., 18(12), 936-946. DOI |
5 | Hall, J.F., Holmes, W.T. and Somers, P. (1996), "Northridge earthquake of January 17, 1994", Earthquake Engineering Research Institute, California, USA. |
6 | Lei, Y.H. and Chien, Y.L. (2009), "Seismic analysis of transmission towers under various line configurations", Struct. Eng. Mech., 31(3), 241-264 DOI |
7 | Li, H.N., Shi, W.L. and Jia, L.G. (2004), "Limitations of effects of lines on in-plane vibration of transmission towers and simplified seismic calculation method", J. Vib. Control., 23(2), 1-7. |
8 | Li, H.N., Shi, W.L., Wang, G.X. and Jia, L.G. (2005), "Simplified models and experimental verification for coupled transmission tower-line system to seismic excitations", J. Sound. Vib., 286(3), 565-585. |
9 | Lu, X.L., Chen, Y. and Mao, Y.J. (2012), "Shaking table model test and numerical analysis of a super tall building with high-level transfer storey", Struct. Des. Tall Spec. Build., 21(10), 699-723. DOI |
10 | NCREE (1999), Investigation Report of Chi-Chi Earthquake, National Center for Research on Earthquake Engineering, Taiwan. |
11 | Park, H.S., Choi, B.H., Kim, J.J. and Lee, T.H. (2016), "Seismic performance evaluation of high voltage transmission towers in South Korea", KSCE J. Civil Eng., 20(6), 2499-2505. DOI |
12 | Sedov, L. (1959), Similarity and Dimensional Methods in Mechanics, CRC Press. |
13 | Shinozuka, M. (1995), "The Hanshin-Awaji earthquake of January 17, 1995 Performance of life lines", Report NCEER-95-0015, NCEER. |
14 | Tian, L., Gai, X. and Qu, B. (2017b), "Shake table tests of steel towers supporting extremely long-span electricity transmission lines under spatially correlated ground motions", Eng. Struct., 132, 791-807. DOI |
15 | Tian, L., Gai, X., Qu, B., Li, H.N. and Zhang, P. (2016), "Influence of spatial variation of ground motions on dynamic responses of supporting towers of overhead electricity transmission systems: an experimental study", Eng. Struct., 128, 67-81. DOI |
16 | Tian, L., Li, H.N. and Liu, G.H. (2012), "Seismic response of power transmission tower-line system under multi-component multi-support excitations", J. Earthq. Tsunami, 6(4), 1250025-1-21. DOI |
17 | Tian, L., Ma, R.S., Li, H.N. and Zhang, P. (2014), "Seismic Response of straight line type and broken line type transmission lines subjected to non-uniform seismic excitations", Adv. Steel. Constr., 10(1), 85-98. |
18 | Tian, L., Niu, Y.H., Ma, R.S., Li, X.J., Yi, S.Y., Xin, A.Q. and Guo, W. (2017c), "Design study on shaking table test model of a long span transmission tower-line system coupling system", World Earthq. Eng., 33(3), 42-50. |
19 | Tian, L., Pan, H.Y., Ma, R.S. and Qiu C.X. (2017a), "Collapse simulations of a long span transmission tower-line system subjected to near-fault ground motions", Earthq. Struct., 13(2), 211-220. DOI |
20 | Wang, W.M., Li, H.N. and Tian, L. (2013), "Progressive collapse analysis of transmission tower-line system under earthquake", Adv. Steel. Constr., 9(2), 161-174. |
21 | Zhang, M.Z. (1997), "Study on similitude laws for shaking table tests", Earthq. Eng. Eng. Vib., 17(2), 52-58. |
22 | Zhou, Y. and Lu, X.L. (2012), Method and Technology for Shaking Table Model Test of Building Structures, Science Press, Beijing, China. |