• Title/Summary/Keyword: Single bubble

Search Result 144, Processing Time 0.027 seconds

A Study on Gas-Liquid Reaction Intensification by Using Rotating Flow (회전유동을 이용한 기체-액체 반응 촉진 기술 연구)

  • Jun Sang Park
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.45-54
    • /
    • 2023
  • In the present study, we propose new type of a spinning disk reactor(SDR) with high performance and very convenient structure to make a large scale equipment from lab-scale than the conventional one. A split-disk experimental equipment, based on new type of spinning disk reactor, has been developed to generate an energy to break a bulk of injected gas into smaller gas bubble. Several cases of an experimental observation make it to confirm that a bulk of injecting gas could be continuously break into smaller bubbles. It shows the feasibility to make a scale-up of SDR by using the characteristic of Taylor-Proudman column in rotating flow. A theoretical study on single phase liquid flow is given to predict a liquid induced shear stress, which make the present study to be self-containment.

Study on the growth of 4H-SiC single crystal with high purity SiC fine powder (고순도 SiC 미분말을 적용한 4H-SiC 단결정 성장에 관한 연구)

  • Shin, Dong-Geun;Kim, Byung-Sook;Son, Hae-Rok;Kim, Moo-Seong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.383-388
    • /
    • 2019
  • High purity SiC fine powder with metal impurity contents of less than 1 ppm was synthesized by improved carbothermal reduction process, and the synthesized powder was used for SiC single crystal growth in RF heating PVT device at temperature above 2,100℃. In-situ x-ray image analyzer was used to observe the sublimation of the powder and single crystal growth behavior during the growth process. SiC powder was used as a source of single crystal growth, exhausted from the outside of the graphite crucible at the growth temperature and left graphite residues. During the growth, the flow of raw materials was concentrated in the middle and influenced the growth behavior of SiC single crystals. This is due to the difference in temperature distribution inside the crucible due to the fine powder. After the single crystal growth was completed, the single crystal ingot was cut into a 1 mm thick single crystal substrate and finely polished using a diamond abrasive slurry. A dark yellow 4H-SiC was observed overall of single crystal substrate, and the polycrystals generated in the outer part may be caused by the incorporation of impurities such as the bubble layer mixed in the process of attaching the seed crystal to the seed holder.

Experimental Study on Heat Flux Partitioning in Subcooled Nucleate Boiling on Vertical Wall (수직 벽면에서 과냉 핵비등 시 열유속 분배에 관한 실험적 연구)

  • Song, Junkyu;Park, Junseok;Jung, Satbyoul;Kim, Hyungdae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.465-474
    • /
    • 2014
  • To validate the accuracy of the boiling heat flux partitioning model, an experiment was performed to investigate how the wall heat flux is divided into the three heat transfer modes of evaporation, quenching, and single-phase convection during subcooled nucleate boiling on a vertical wall. For the experimental partitioning of the wall heat flux, the wall heat flux and liquid-vapor distributions were simultaneously obtained using synchronized infrared thermometry and the total reflection technique. Boiling experiments of water with subcooling of $10^{\circ}C$ were conducted under atmospheric pressure, and the results obtained at the wall superheat of $12^{\circ}C$ and average heat flux of $283kW/m^2$were analyzed. There was a large difference in the heat flux partitioning results between the experiment and correlation, and the bubble departure diameter and bubble influence factor, which account for a portion of the surrounding superheated liquid layer detached by the departure of a bubble, were found to be important fundamental boiling parameters.

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Experimental study on vertically upward steam-water two-phase flow patterns in narrow rectangular channel

  • Zhou, Jiancheng;Ye, Tianzhou;Zhang, Dalin;Song, Gongle;Sun, Rulei;Deng, Jian;Tian, Wenxi;Su, G.H.;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.61-68
    • /
    • 2021
  • Experiments of vertically upward steam-water two-phase flow have been carried out in single-side heated narrow rectangular channel with a gap of 3 mm. Flow patterns were identified and classified through visualization directly. Slug flow was only observed at 0.2 MPa but replaced by block-bubble flow at 1.0 MPa. Flow pattern maps at the pressure of 0.2 MPa and 1.0 MPa were plotted and the difference was analyzed. The experimental data has been compared with other flow pattern maps and transition criteria. The results show reasonable agreement with Hosler's, while a wide discrepancy is observed when compared with air-water two-phase experimental data. Current criteria developed based on air-water experiments poorly predict bubble-slug flow transition due to the different formation and growth of bubbles. This work is significant for researches on heat transfer, bubble dynamics and flow instability.

Growth and photoluminescence properties of Er : Mg : LiNbO$_3$single crystal fibers by $\mu$-PD method ($\mu$-PD법에 의한 Er : Mg : LiNbO$_3$fiber 결정 성장 및 형광특성)

  • 양우석;윤대호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.6
    • /
    • pp.389-393
    • /
    • 2000
  • High-quality $Er^{3+}$ doped Mg : $LiNbO_3$single crystal fibers were grown by a micro-pulling down ($\mu$-PD) method. Single crystal fibers were pulled down through the nozzle, at a pulling down rate of 0.5 mm/min and using a Pt crucible with a nozzle 1 mm in diameter in air atmosphere. Defects such as bubbles, cracks and inclusions were not detected in any of the grown crystals. The optical transmission of Er : Mg : $LiNbO_3$crystal was measured and the energy levels of $Er_2O_3$ ion could be calculated. The photoluminescence spectrum of crystal fibers showed an energy band emission with the strongest line corresponding to the $^4I_{3/2}{\to}^4I_{15/2}$transition. The concentration dependence of the entire wavelength region emission intensity upon excitation intensity measured emission intensity for the 3 mol% MgO doped fibers was larger than that for the 1, 5 mol% MgO doped fibers.

  • PDF

A Study on the Improvement of Condensation and Boiling Heat Transfer on Horizntal Tube by Fin Effect(l)-Shellside Boiling- (수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (1)-튜브외부 비등-)

  • 한규일;조동현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1264-1274
    • /
    • 1994
  • Heat transfer performance of integral-fin tube which is used in recipro turbo refrigerator or high compact heat exchangers is studied. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 internal grooves are tested. A plain tube having the same(inner and outer) diameter as the fin tubes is also tested for comparison. Pool boiling heat transfer of R-11 is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at saturation state of 1 bar on the outside tube surface and heat is supplied by not water which circulates inside of the tube. From the result of eight fin tubes and one plain tube tested, a tube having 1299 fpm-30 grooves shows the best performance. A maximum overall heat transfer coefficient of this tube is about 4000 $W/m^{2}K$ at 2.8m/s of water velocity. The maximum heat transfer enhancement (i.e., the ratio of overall heat transfer coefficients of finned to plain tubes)is about 2.1.

Lock-on states of a circular cylinder in the oscillatory flow (진동 유동장에서 원형 실린더의 lock-on 해석)

  • Kim Wontae;Sung Jaeyong;Yoo Jung Yul
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.245-248
    • /
    • 2002
  • Vortex lock-on or resonance in the flow behind a circular cylinder is visualized by a time-resolved PIV when a single frequency oscillation is superimposed on the mean incident velocity. Measurements are made of the $K{\'{a}}rm{\'{a}}n$ vortices in the wake-transition regime at the Reynolds number 360. Basically, natural shedding state is observed to compare with lock-on state. Wake motion by the change of the shedding frequency of lock-on state is investigated. When lock-on occurs, the vortex shedding frequency is found to be half the oscillation frequency as expected from previous experiments. The physical flow phenomena of natural shedding and lock-on states are analyzed with physical parameters of recirculation and vortex formation region. Consequently, it is found that the change of wake bubble plays an important role in the flow at the lock-on state. Vortex formation region is also actively changed like recirculation region as the lock-on occurs. Therefore, it is deduced that the recirculation region is closely related with the vortex formation region.

  • PDF

Removal of Non-biodegradable Organic Contaminants in Wastewater from crude oil reserve base Using Pulse UV System (Pulse UV 장치를 이용한 원유비축시설 발생폐수의 난분해성 유기오염물질 제거)

  • Sohn, Jin-Sik;Park, Soon-Ho;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.861-867
    • /
    • 2011
  • Wastewater from crude oil reserve base usually contains large amount of non-biodegradable contaminants. The conventional wastewater treatment progress can hardly meet the regulation of wastewater effluent quality. This study investigated the removal of non-biodegradable organic contaminants in wastewater from crude oil reserve base using a pulse UV treatment. The modified process incorporating pulse UV process was set up to treat the wastewater from crude oil reserve base. The treatment process is composed with coagulation and flocculation, micro-bubble flotation, sand filter, pulse UV system, and GAC filter. The results show CODMn was effectively removed by the process with pulse UV system and it can meet the wastewater effluent regulation. The single effect of pulse UV process in CODMn removal was not significant(9~15% based on sand filtered effluent), however with the subsequent activated carbon filter the removal ratio CODMn was increased up to 28% compared to the process without pulse UV syetem.

A 1.2 V 7-bit 1 GS/s CMOS Flash ADC with Cascaded Voting and Offset Calibration

  • Jang, Young-Chan;Bae, Jun-Hyun;Lee, Ho-Young;You, Yong-Sang;Kim, Jae-Whui;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.4
    • /
    • pp.318-325
    • /
    • 2008
  • A 1.2 V 7-bit 1 GS/s CMOS flash ADC with an interpolation factor of 4 is implemented by using a $0.13\;{\mu}m$ CMOS process. A digital calibration of DC reference voltage is proposed for the $1^{st}$ preamp array to compensate for the input offset voltage of differrential amplifiers without disturbing the high-speed signal path. A 3-stage cascaded voting process is used in the digital encoder block to eliminate the conescutive bubbles up to seven completely, if the $2^{nd}$ preamp output is assumed to have a single bubble at most. ENOB and the power consumption were measured to be 5.88 bits and 212 mW with a 195 MHz $400\;mV_{p-p}$ sine wave input.