• Title/Summary/Keyword: Simultaneous measurement

Search Result 482, Processing Time 0.027 seconds

Proposition of copper-foil magnetic sensor for the two-axis remote measurement of bending vibration of a non-metallic cylinder (비금속 배관에서의 원격 2 축 굽힘 진동 측정을 위한 동박 패치형 자기 센서의 제안)

  • Kim, Jin-Ki;Han, Soon-Woo;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.322-325
    • /
    • 2007
  • This paper suggests a non-contact sensor for measuring bending vibration of a non-metallic cylinder in two orthogonal directions simultaneously. Recent research shows that a solenoid can pick up bending vibrations of a nonmetallic cylinder based on the reversed Lorentz force mechanism if an electrical conductive patch is attached to the cylinder. In this work, pairs of specially designed patches are used to make two independent paths for the current induced by bending vibrations, which enables the measurement of bending vibrations along two orthogonal directions simultaneously. The working performance of the developed sensor was verified by using two accelerometers.

  • PDF

Measurement of the Velocity field of Rotor-Stator in a Centrifugal Turbine Pump by Using PIV (PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측)

  • Im, Yu-Cheong;Seo, Min-Sik;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.11-18
    • /
    • 1998
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stator region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Fine optical setup deeply concerned with PIV performance is arranged for accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

Proposition of Copper - Foil Magnetic Sensor for the Two-axis Remote Measurement of Bending Vibration of a Non-metallic Cylinder (비금속 배관에서의 원격 2축 굽힘 진동 측정을 위한 동박 패치형 자기 센서의 제안)

  • Kim, Jin-Ki;Han, Soon-Woo;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.381-385
    • /
    • 2008
  • This paper suggests a non-contact sensor for measuring bending vibration of a non-metallic cylinder in two orthogonal directions simultaneously. Recent research shows that a solenoid can pick up bending vibrations of a nonmetallic cylinder based on the reversed Lorentz force mechanism if an electrically conductive patch is attached to the cylinder. In this work, pairs of specially designed patches are used to make two independent paths for the current induced by bending vibrations, which enables the measurement of bending vibrations along two orthogonal directions simultaneously. The working performance of the developed sensor was verified by using two accelerometers.

A Study on Flow and Efficiency Characteristics in Guide Vane of Diffuser Pump Using PIV Measurement (PIV 계측을 이용한 디퓨져펌프의 정익에서의 성능과 유동특성에 관한 연구)

  • Kim, J. H.;Choi, M. S.;Kim, J. G.;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.29-35
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

Flow Characteristics of Guide Vane of Diffuser Pump by PIV Measurement (PIV계측에 의한 디퓨져펌프 안내깃에서의 유동특성)

  • Kim, J.H.;Choi, J.W.;Kim, M.Y.;Lee, H.;Lee, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.391-396
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within a diffuser pump. Various different kinds of clearance were selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors was implemented with direct calculation of correlation coefficients. Fine optical setup important in PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Various flow patterns are represented quantitatively at the stator passages.

  • PDF

A PIV Measurement on Flow Characteristics inner Diffuser Pump Using High Resolution CCD Camera (고해상도 CCD 카메라를 이용한 디퓨져펌프 내부 유동특성에 대한 PIV 계측)

  • 김성윤;김범석;김정환;김유택;이영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.161-166
    • /
    • 2002
  • The resent experimental study is focused on the application of multi-point simultaneous measurement by PIV Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational veto ity and changing clearance between Guide Vane and Impeller were selected as experimental condition. Optimized ross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coeffi cients. Fine optical setup concerned with PW performance is arranged for the accurate PW measurement of high peed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

Real-time Measurement and Compensation of Motion Errors Using Extended Twyman-Green Interferometry (확장 트와이만-그린 간섭계를 이용한 운동 오차의 실시간 측정 및 보상)

  • 오정석;배은덕;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.288-291
    • /
    • 2003
  • This paper presents an extended Twyman-Green interferometry that enables simultaneous and real-time measurement of 5-DOF motion errors of the translational moving stage. This method uses a null balancing technique in which two plane mirrors are used as target mirrors to generate an interferometric fringe utilizing the optical principles of Twyman-Green interferometry. Fringe is detected by 2D photodiode array for high-speed measurement. Errors are then independently suppressed by activation of piezoelectric actuators through real-time feedback control while the machine axis is moving. Experimental results demonstrate that a machine axis can be controlled with motion errors about 10 nm in linear displacement, 0.15 arcsec in angular displacement

  • PDF

An Combustion Diagnosis Using Optical Measurement in D. I Diesel Engine with Dual Fuel Stratified Injection System (이종연료 층상분사를 적용한 디젤엔진에서 광 계측을 이용한 연소해석)

  • An, H.C.;Kang, B.M.;Yeom, J.K.;Chung, S.S.;Ha, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.31-37
    • /
    • 2002
  • In previous study, diesel-methanol stratified injection system is manufactured and applied to a D.I. diesel engine in order to realize combustion improvement using methanol, which is oxygenated fuel with large latent heat. We know that NOx and soot is reduced by stratified injection of diesel fuel-methanol. Therefore, in the present study, combustion diagnosis using optical measurement is tried to make clear effect of methanol on simultaneous reduction of NOx and soot. Two-color method is used to measure flame temperature and KL value, which is approximately proportional to the soot consentration along the optical path. Laser induced scattering method was used to measure distribution of soot at two dimensional area. Also, it is compared exhaust characteristics of NOx and soot with results of optical measurement.

  • PDF

Measurement of the Velocity Field of Rotor-Stator in a Centrifugal Turbine Pump Using PIV (PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측)

  • Im, Yu-Cheong;Seo, Min-Sik;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.35-42
    • /
    • 1999
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stater region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

Development of a multi-sensing technique for temperature and strain field of high-temperature using thermographic phosphors (온도감응형 인광물질을 이용한 온도장 및 열변형 동시 계측 기법 개발)

  • Im, Yujin;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • Solid oxide fuel cell (SOFC) operates at high temperatures in range of 600-800℃. Since layers of SOFC are composed of different substances, different thermal expansion in SOFC can result in defects under high temperature conditions. For understanding relation between temperature field and the thermal deformation in SOFC, temperature and strain field were simultaneously estimated using thermographic phosphors by optical measurement. Temperature fields were obtained by the life-time method, and the temperature differences of one specimen was checked with thermocouple. The thermal deformation was estimated by digital image correlation (DIC) method with extracted phosphorescence images. To investigate the deformation accuracy of DIC measurement, thermographic phosphors were coated with and without grid pattern on aluminum surface. Simultaneous measurement of temperature fields and thermal deformation were carried out for YSZ. This study will be helpful to multi-sensing of temperature field and thermal deformation on SOFC cells.