• Title/Summary/Keyword: Simultaneous instrumentation

Search Result 20, Processing Time 0.032 seconds

Pyogenic Spondylitis with Diffuse Spinal Epidural Abscess - A Case Report - (미만성 척수 경막외 농양을 동반한 화농성 척추염 - 증 례 보 고 -)

  • Kim, Hun;Kim, Sung Min;Chung, Dai Jin;Shim, Young Bo;Park, Yong Kee;Choi, Sun Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1074-1079
    • /
    • 2000
  • We report a case of pyogenic spondylitis on L2 and L3 with diffuse epidural abscess up to T4 to L3 and large psoas abscess. A forty-nine-year old male was presented with progressive back pain, left flank pain and ab-dominal distention, weakness of the both legs and voiding and defecation difficulty during last 2 months. Initially multiple coronal hemilaminectomies from T4 to T12 were done for the treatment of diffuse thoracic epidural ab-scess. Then second operation via left retroperitoneal approach was performed for lumbar spondylitis and psoas abscess on third day after initial operation. After removal and curettage of pyogenic psoas and epidural abscess and spondylitis (L2-L3), iliac bone grafting with Keneda instrumentation from L1 to L4 was done simultaneously. Postoperative course has been unevenful without recurrent infection. The literature on diffuse epidural and large psoas abscess with pyogenic spondylitis are reviewed and instrumentation for stabilization of pyogenic spondylitis is also discussed.

  • PDF

A Simultaneous Design of TSK - Linguistic Fuzzy Models with Uncertain Fuzzy Output

  • Kwak, Keun-Chang;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.427-432
    • /
    • 2005
  • This paper is concerned with a simultaneous design of TSK (Takagi-Sugeno-Kang)-linguistic fuzzy models with uncertain model output and the computationally efficient representation. For this purpose, we use the fundamental idea of linguistic models introduced by Pedrycz and develop their comprehensive design framework. The design process consists of several main phases such as (a) the automatic generation of the linguistic contexts by probabilistic distribution using CDF (conditional density function) and PDF (probability density function) (b) performing context-based fuzzy clustering preserving homogeneity based on the concept of fuzzy granulation (c) augment of bias term to compensate bias error (d) combination of TSK and linguistic context in the consequent part. Finally, we contrast the performance of the enhanced models with other fuzzy models for automobile MPG predication data and coagulant dosing process in a water purification plant.

  • PDF

Simultaneous Measurements of Gaseous Nitrous Acid and Particulate Nitrite Using Diffusion Scrubber/Steam Chamber/Luminol Chemiluminescence

  • Chang, Won-Il;Choi, Jung-Ho;Hong, Sang-Bum;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.8
    • /
    • pp.1525-1532
    • /
    • 2008
  • An instrument was developed for the simultaneous determination of gas- and aerosol-phase nitrous acid (HONO). Gaseous HONO (HONO(g)) was sampled by a diffusion scrubber and particulate nitrite ($NO_2\;^-$(p)) was collected by a particle growth chamber. The collected samples were analyzed in time-sharing manner, based on the peroxynitrite-induced luminol chemiluminescence. The automated system was found to be sensitive with 13 pptv of detection limit, fast with 4 min. of sampling frequency, and simple and affordable to construct and operate. The system was optimized by adjusting the experimental parameters. The system was applied to the field measurement of gas- and particle-phase HONO during the springtime of 2004 in Gwangju, South Korea. HONO(g) concentrations varied diurnally from 200 pptv around 3 P.M. to 800 pptv at 5 A.M. The variation of $NO_2\;^-$(p) was not significant with the maximum of 240 pptv at 11 P.M. and the minimum of 170 pptv at 4 P.M., not displaying distinct characteristics.

A Simple and Simultaneous Analysis of Volatile Halogenated Hydrocarbons in Indoor Air Using Personal Sampler

  • Jung, Won-Tae;Sohn, Dong-Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.E
    • /
    • pp.373-381
    • /
    • 1993
  • To understand the human exposure levels of volatile halogenated hydrocar-bons in ambient air, a new rapid and convenient analytical method for determination of the compounds in gaseous phase was evaluated and established. The method is based upon passsive diffusion to personal sampler containing adsorbent and solvent extraction followed by purge trap/ on-column cryof-ocusing method. A new method needs no special instrumentation for gas collection because it is based upon the passive diffusion principle. The typical chromatogram obtained in this study proved that rapid and simultaneous determination of target analytes was possible with good resolution. The developed method was successfully applied to determine the volatile halogenated hydrocarbons in indoor air and the values obtained by this new method were compared with those by direct suction method. The concentration of carbon tetrachloride, 1,1,2-trichloroethylene, chloroform showed the values below 400$\mug/m^3$ except the maximum of 1,513$\mug/m^3$ of chloroform. 1,1,1-Trichloroethane showed approximately 1,000 to 5,000$\mug/m^3$ range of diurnal fluctuation in indoor air.

  • PDF

Specimen Preparation for Scanning Electron Microscope Using a Converted Sample Stage

  • Kim, Hyelan;Kim, Hyo-Sik;Yu, Seungmin;Bae, Tae-Sung
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.214-217
    • /
    • 2015
  • This study introduces metal coating as an effective sample preparation method to remove charge-up caused by the shadow effect during field emission scanning electron microscope (FE-SEM) analysis of dynamic structured samples. During a FE-SEM analysis, charge-up occurs when the primary electrons (input electrons) that scan the specimens are not equal to the output electrons (secondary electrons, backscattered electrons, auger electrons, etc.) generated from the specimens. To remove charge-up, a metal layer of Pt, Au or Pd is applied on the surface of the sample. However, in some cases, charge-up still occurs due to the shadow effect. This study developed a coating method that effectively removes charge-up. By creating a converted sample stage capable of simultaneous tilt and rotation, the shadow effect was successfully removed, and image data without charge-up were obtained.

AN OBSERVATION PROGRAM FOR THE SOAO 2K CCD CAMERA (소백산천문대 2K CCD 카메라용 관측 프로그램 개발)

  • KIM SEUNG-LEE;KYEONG JAE-MANN;KWON SUN-GIL;YOUN JAE-HYOUK
    • Publications of The Korean Astronomical Society
    • /
    • v.16 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • We developed an observation program for a 2K CCD camera, which was newly attached at the SOAO (Sobaeksan Optical Astronomy Observatory) 61cm telescope. The program was designed to control the telescope as well as the CCD camera and to monitor the CCD image quality, with very easy under the window-based graphical user interface (GUI). Furthermore, applying the automated differential photometric algorithm, we can obtain the instrumental magnitudes of several variable and comparison stars in real-time. Simultaneous photometry enables us to get precise differential magnitudes of variable stars even if the weather condition is not photometric. This new observation system has been using for many astronomical observations from September, 2001.

  • PDF

Localization of Mobile Robot using Local Map and Kalman Filtering (지역 지도와 칼만 필터를 이용한 이동 로봇의 위치 추정)

  • Lim, Byung-Hyun;Kim, Yeong-Min;Hwang, Jong-Sun;Ko, Nak-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1227-1230
    • /
    • 2003
  • In this paper, we propose a pose estimation method using local map acquired from 2d laser range finder information. The proposed method uses extended kalman filter. The state equation is a navigation system equation of Nomad Super Scout II. The measurement equation is a map-based measurement equation using a SICK PLS 101-112 sensor. We describe a map consisting of geometric features such as plane, edge and corner. For pose estimation we scan external environments by laser rage finer. And then these data are fed to kalman filter to estimate robot pose and position. The proposed method enables very fast simultaneous map building and pose estimation.

  • PDF

Development of an Equilibrium Sensation Measuring System for Human Being (사람의 평형감각 측정시스템 개발)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.62-69
    • /
    • 2009
  • This paper describes the development of the new type equilibrium sensation measuring system for human with handicap in the equilibrium sensation. The medium and small hospital could not use the developed equilibrium sensation measuring system, because it is very high prices. Therefore, the new type system should be developed to measure the numerical value of the equilibrium sensation in human with handicap. In this paper, First, two 3-axis force/moment sensors which can measure force Fz, moments Mx and My simultaneous were designed and manufactured, second, the high speed measuring device which can acquire the output from two 3-axis force/moment sensors, third, the new type equilibrium sensation measuring system was developed, then the characteristic test of the developed equilibrium sensation measuring system carried out, it is confirmed that the system could measure the swing body of human with handicap.

Thermal Analysis of Ceramic Materials (세라믹스 재료의 열분석)

  • Cha, Jaemin;Liu, Liyu;Ryu, Bongki
    • Ceramist
    • /
    • v.22 no.4
    • /
    • pp.393-401
    • /
    • 2019
  • Thermal analysis means the analysis of a change in a property of a sample, which is related to an imposed temperature alteration. Measurements are usually made with increasing temperature, but isothermal measurements or measurements made with decreasing temperatures are also possible. In fact, any measuring technique can be made into a thermal analysis technique by adding thermal control. Simultaneous use of multiple techniques increases the power of thermal analysis, and modern instrumentation has permitted extensive growth of application. The basic theories of thermal analysis are well developed and some of them are explained in this paper.

Scientific and Engineering Applications of Full-field Swept-source Optical Coherence Tomography

  • Mehta, Dalip Singh;Anna, Tulsi;Shakher, Chandra
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.341-348
    • /
    • 2009
  • We report the development of full-field swept-source optical coherence tomography (SS-OCT) in the wavelength range of 815-870 nm using a unique combination of super-luminescent diode (SLD) as broad-band light source and acousto-optic tunable filter (AOTF) as a frequency-scanning device. Some new applications of full-field SS-OCT in forensic sciences and engineering materials have been demonstrated. Results of simultaneous topography and tomography of latent fingerprints, silicon microelectronic circuits and composite materials are presented. The main advantages of the present system are completely non-mechanical scanning, wide-field, compact and low-cost.