• Title/Summary/Keyword: Simulex

Search Result 33, Processing Time 0.023 seconds

Safety Assessment of the Evacuation at School Building by Escape Training and Simulation (학교건물에서 피난훈련과 시뮬레이션을 통한 피난안전성 평가)

  • Jeong, Mu-Heon;Lee, Beong-Gon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • In this study, the evacuation training were performed in a high school building in Cheong-Ju and compared with the simulation program (Simulex). Also numerical analysis of room fire in school building was conducted by fire model (FDS, CFAST) and evaluated the available safe egress time for the safety assessment. As a result, the 8% of total egress persons were failed to escape at evacuation training and 40% of total egress persons were failed to escape at Simutex simulation. Simutex program was not reflected the real escape conditions, such as evacuation route, refuge place, etc.

A Study on the Egress Model Analysis using EXODUS, SIMULEX (EXODUS, SIMULEX를 활용한 피난모델 분석에 관한 연구)

  • Seo, Dong-Goo;Hwang, Eun-Kyung;Hwang, Geum-Suk;Jo, Jeong-Hoon;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.33-36
    • /
    • 2008
  • Recently with the increasing economics, many hish-rise and complicated building with new architecture features are constructed in Korea. These higher and bigger building have many difficulties of fire safety concerns, especially evacuation plan. In this paper, aims to present logical basis for forecasting egress behavior of occupants and systematized Egress-Prediction Model by analysing expectable decisive factors among influential factors each step until completing egress from perception of fire cues.

  • PDF

A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities (대규모 위락시설의 피난안전성능 평가에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.165-173
    • /
    • 2009
  • As the Performance Based Fire Protection Design is legislated, studies on a fire and evacuation are actively in progress. The Performance Based Fire Protection Design should be developed toward enlarging the Life safety. In addition, the Performance Based Fire Protection Design shall not merely review the aspects of fire fighting but it shall also include regulations pertaining to evacuation stipulated in laws and regulations for buildings. This study performed an evacuation time prediction based on OO Night Club, one of the multiplex use facilities located in Gwang-ju Metropolitan City in order to suggest as a referential data for the Performance Based Fire Protection Design implementation. To do this, I investigated domestic and foreign regulations and research papers related to evacuation and went to visit the actual site and collected materials. The collected data was then used as ones to input in Simulex, an evacuation program to measure evacuation time. The collected data was then used as data to input in Simulex, an evacuation program to measure evacuation time. Through this particular research and results, the study was able to suggest a few concerning areas.

A Study on the Evacuation Performance Review for the Office Buildings (업무용 빌딩의 피난 성능 검토에 관한 연구)

  • 오혁진;백승태;김우석;이수경
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-6
    • /
    • 2003
  • In this study, it reviewed about evacuation performance of a specified Office Building. assessment tools is FAST 3.1.7 (Estimation of Flash Over, Estimation of Layer Height Down Flow Time), SIMULEX 32-bit (Estimation of Evacuation Time), JASMINE 3.25d. (Smoke Flow Assessment of a specified time) Result from Fire Scenario # 1, Flash Over is not generated in Compartment. Evacuation Time is estimated 25.2 sec by SIMULEX 32-bit. layer height until this time (25.2 sec) was estimated 2.4 m by FAST 3.1.7. After ignition until this time (25.2 sec), smoke was not release to the a corridor. In consequence, We concluded that people in building are completing the safe evacuation without the damage of smoke. Result from Fire Scenario # 1, Flash Over generated 6 min 33.2 sec in Compartment. Evacuation Time is estimated 1 min 25.5 sec by SIMULEX 32-bit. layer height down flow time is 1 min 40.8 sec by FAST 3.1.7 and 5 min 23 sec by theoretical calculation. Also, total building evacuation time was estimated 2 min 26.6 sec. After ignition until this time (2 min 26.6 sec), smoke released to the a corridor but it amount was few little. Therefore, generated smoke in compartment not effected to the people in buildings.

A Study on Comparison of Improved Floor Field Model and Other Evacuation Models (개선된 Floor Field Model과 다른 피난시뮬레이션 모델의 비교 연구)

  • Nam, Hyunwoo;Kwak, Suyeong;Jun, Chulmin
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.3
    • /
    • pp.41-51
    • /
    • 2016
  • In this study, we propose an improved Floor Field Model(FFM) that considers the physical characteristics of pedestrians, i.e., body size, shape, and posture. Also we analyse limits of FFM and features of improved model compared with existing evacuation simulation models. FFM is a typical microscopic pedestrian model using CA, but it does not reflect the physical characteristics of pedestrians. Because of this, FFM is difficult to modeling phenomena such as collision, friction between pedestrians. As a result, FFM calculates a very short evacuation time when compared with the other models. We performed a computational experiment to compare improved model with other models such as FFM, Simulex, Pathfinder in an actual campus building. We carried out a comparison of evacuation aspect according to the change in number of evacuees. Also we compared evacuation aspect by exit. Finally, we confirmed that improved model reflects physical phenomena which were not reflected in FFM. Especially, experimental results were very similar to the Simulex.

A Study on the Construction of Korean Evacuation Load Model (한국형 재실자 피난부하모델 구축에 관한 연구)

  • Lee, Jeong-Soo;Kwon, Heung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5221-5229
    • /
    • 2013
  • This study focused on the construction of Korean Evacuation load Model for reflecting Korean Evacuation behaviors. For the purposes, several evacuation experiments are executed according to the ages, and the level and types of disabilities. We accumulated the data on the evacuation velocity and behavior patterns according the ages, and the level and types of disabilities. From these results, we proposed the Korean Evacuation Load Model and compared with several popular evacuation simulation model such SIMULEX. As results of these studies, we found the possibility of construction of Korean Evacuation Simulation System based on the Korean Evacuation Model including the evacuation velocity and human behaviors.

A Study on the Evaluation of Evacuation Safety Function of an Elderly Care Hospital (일개 노인요양병원의 피난안전성능 평가에 관한 연구)

  • Kim, Jong-Bum;Kim, Ja-Ok;Back, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.9-19
    • /
    • 2010
  • Recently, Korea is constantly increasing its elderly care hospitals, and requires establishment of general evacuation plan considering old people's behavioral characteristics and physical states in emergency situations such as fire, and etc. In addition, because most of the facility users are patients under serious dementia and stroke, they feel difficulty evacuating by themselves, with differing evacuation time according to each walking status (bed, wheel chair, and various supplementary instruments), which is why it makes it difficult to have them all evacuate. This paper, in order to suggest data reference for designing on the basis of functionality, used various collected data utilizing Simulex to measure evacuation time through the model of elderly care hospital, a medical facility. During the study, several problems were found.

Comparison of Egress Modeling for the Connected Space from Subway Car to Platform (지하철 차량과 승강장의 연계공간에 대한 피난모델링 적용비교)

  • Kim, Jong-Hoon;Seo, Dong-Hoon;Eo, Deuk-Gang;Kim, Woon-Hyung;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.870-873
    • /
    • 2011
  • The circumstance as platform and tunnel is very important in evacuation from passenger train car on fire. The comparison of egress modeling by SIMULEX, PATHFINDER, STEPS was conducted in order to analyze for the influence of platform to egress from subway car. Model subway car is seoul metro subway car. Model platform was designed by code 'Complementary design guide for connecting and convenience facilities, and urban subway station'.

  • PDF