• 제목/요약/키워드: Simulation of PV module

검색결과 94건 처리시간 0.024초

유한 요소 해석 프로그램을 이용한 모듈 내 온도 분포 예측 (Prediction of temperature distribution in PV module using finite element method)

  • 박영은;정태희;고석환;주영철;김준태;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.65-72
    • /
    • 2016
  • PV module is installed in various outdoor conditions such as solar irradiation, ambient temperature, wind speed and etc. Increase in solar cell temperature within PV module aggravates the behaviour and durability of PV module. It is difficult to measure temperature among respective PV module components during PV module operating, because the temperature within PV module depends on thermal characteristics of PV module components materials as well as operating conditions such as irradiation, outdoor temperature, wind etc. In this paper, simulation by using finite element method is conducted to predict the temperature of each components within PV module installed to outdoor circumstance. PV module structure based on conventional crystalline Si module is designed and the measured values of thickness and thermal parameters of component materials are used. The validation of simulation model is confirmed by comparing the calculated results with the measured temperatures data of PV module. The simulation model is also applied to estimate the thermal radiation of PV module by front glass and back sheet.

Matlab을 이용한 PV모듈의 I-V시뮬레이션 관한 연구 (Study on I-V simulation for PV module with matlab)

  • 홍종경;정태희;강기환;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.1-6
    • /
    • 2009
  • This paper estimates numerically cells the electrical characteristics of the PV module with environmental changes such as shunt resistance, series resistance, temperature, irradiance. Series resistance $R_s$ including diode characteristic resistance $r_d$ is derived from the p-n junction diode model. I-V characteristics of this model with series resistance $R_s$ are simulated on Matlab. Finally, theoretical I-V characteristics are compared with those of solar simulator. Those results agreed well within the manufacturer's maximum error range 3%

설치환경 및 조건에 따른 양면수광형 태양광발전시스템의 기초 특성 연구 (A Preliminary Research of the Bifacial PV System Under Installation Conditions)

  • 장주희;권오현;이상혁;신민수;이경수
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.51-63
    • /
    • 2018
  • Nowadays the bifacial PV system market and its applications are increasing rapidly. The performance of the bifacial PV system take advantage of its rear surface irradiance. Also, the ground albedo, PV module tilt and azimuth, PV module installation height, shading effect and module temperature are factors of bifacial PV system performance. This paper investigates how the performance of bifacial PV system is influenced by above factors. First, we analyzed the energy yield depending on PV module installation by simulation. Secondly, we compare energy performance evaluation of monofacial and bifacial module on different weather condition by experiment. Thirdly, we tested the albedo effect and checked operating characteristics using Dupont Tyvek material for the bifacial PV module. Fourthly, we check the shading effect of bifacial PV module on bypass diode operating. Finally, we applied the bifacial PV module in the nearby subway station for the noise reduction barrier using a qualified simulation program. In summary, we confirm that the energy performance superiority of the bifacial PV module has a lot of application use including road. Also, we have confirmed the bifacial module and inverter design should be considered by rear surface irradiance.

일사량 분석을 통한 PV모듈 발전량과 시뮬레이션을 이용한 실내 조명에너지 절감량 비교 (A Study on the Comparison of the PV Module Generation from Daylight Irradiation and Indoor Lighting Savings with Lighting Simulation)

  • 박윤민;홍성관;최안섭
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.17-24
    • /
    • 2010
  • Recently, BIPV system which is good enough for maintenance and functions with the shading system is being used. However BIPV system with the shading system is different from existing PV module because of using flexible PV module. Prior to the application of the BIPV system, the clearness index was calculated by Erbs et al.(1982) and analyzed for the amount of electric power generation of sky irradiance with measured data. To predict electric lighting energy savings in daylit space, electric lighting power savings with amount of PV module electric power generation was compared by using Relux 2010 software in this study.

해석모델을 이용한 태양광모듈의 성능결과 비교분석 (Comparison Results of Photovoltaic Module Performance using Simulation Model)

  • 소정훈;유병규;황혜미;유권종
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.56-61
    • /
    • 2008
  • The modeling of PV (Photovoltaic) module is useful to perform detailed analysis of PV system performance for changing meteorological conditions, verify actual rated power of PV system sizing and determine the optimal design of PV system and components. This paper indicates a modeling approach of PV module performance in terms of meteorological conditions and identifies validity of this modeling method by comparing measured with simulated value of various PV modules using simulation model.

기계 하중에 따른 PV모듈 변형 분석 (An analysis of the deformation of PV module under different mechanical loads)

  • 최주호;정태희;송희은;김일수;장효식;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.58-66
    • /
    • 2013
  • Recently, PV module that the most important part of the photovoltaic system is more widened to lower manufacturing costs for module. However, the broad PV module results to the serious mechanical damage corning from installation circumstances such as snow, wind etc of snow and finally lead to the dramatic degradation of the electrical behavior of PV module. In this paper, 3 kinds of PV modules that consist of the different thickness and area of front glass and the diverse cross sectional structures of the frame are prepared for this experiment. The drooped length and electrical outputs of the PV modules are measured by means of applying 600Pa mechanical load to the PV modules from 1200Pa to 5400Pa base on the mechanical load test procedure of K SC IEG 61215 standard. The simulation data are obtained by the simulation tool as ANSYS and those are validate by comparing with the those experimental results figure out relations between the deformation and the constituent part of PV module.

PV module을 이용한 옹벽용 반사판 특성에 관한 연구 (A Study on the characteristic a reflector of retaining wall by PV module)

  • 김대근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.41-44
    • /
    • 2000
  • This paper represent about design of the controller for battery of a reflector of retaining wall for power supply using PV Module. Simulation is represents V-I and power characteristic by Mathematica & Design Cneter 6.3 & Qnet 2.1 Finally we composed of road surface-signpost system. This system is successfully operating with high clearness lights.

  • PDF

방열핀을 부착한 태양전지 모듈의 열적특성 연구 (A Study on the Thermal Characteristics of Photovoltaic Modules with Fin)

  • 김종필;임호;전충환;장영준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.114-117
    • /
    • 2009
  • The performance of PV module applying the photovoltaic effects of the semiconductor is affected by temperature. Until now, most of PV module show that the power and efficiency falls at a rate of ${\sim}0.5%/^{\circ}C$ and ${\sim}0.05%/^{\circ}C$ respectively as increase of ambient temperature. In this study, the effect of fins attached to the backside of PV module was investigated through a thermal analysis program and simulation model. The result shows that the inner temperature of PV module with fin falls about $10^{\circ}C$ compare to that of ordinary PV module.

  • PDF

태양광 PV 스트링에서의 모듈 부정합 손실의 분석 및 개선 기법 타당성 연구 (Analysis of Module Mismatch Loss in Solar PV String and Feasibility Study for Improvement Method)

  • 안희욱
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.58-63
    • /
    • 2009
  • In this paper, the power loss due to PV module mismatch in PV string is analyzed and a mismatch compensation method is proposed to improve the efficiency of PV system. The analysis of mismatch loss using PV model simulation reveals that the mismatch module may decrease the total efficiency because the MPPT function of power conditioner make the PV system operate at the local maximum point. The mismatch loss can be severe if the maximum power point current of mismatch module is less than that of string. The proposed compensation method which is simply implemented with a buck type converter shows the possibility to remove the mismatch loss. The effectiveness of the analysis and compensation method is verified by a prototype experiment.

태양전지의 출력 불균일에 대한 최대전력 알고리즘 연구 (The Study on MPPT Algorithm of PV Module by mismatched Solar Cell)

  • 심재휘;최주엽;최익;이상철;이동하
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.143-148
    • /
    • 2011
  • This paper is about the study on MPPT algorithm of PV module where mismatched solar cells exist. PSIM simulation tool was used to verify new MPPT algorithm and PV module modeling was made. It was verified for the proposed algorithm to track the right MPP of PV boost converter under mismatched condition, which shows a shading effect in PV module. An experiment will be done soon using PV simulator for verification of the proposed algorithm.

  • PDF