• Title/Summary/Keyword: Simple Technique

Search Result 3,399, Processing Time 0.038 seconds

A Simple AMC Technique using ARQ for a MIMO-OFDM System based on IEEE 802.11a WLANs (IEEE 802.11a WLAN 기반 MIMO-OFDM 시스템에서 ARQ를 이용한 간단한 적응변조 기법)

  • 유승연;김경연;이충용;홍대식;박현철
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.7
    • /
    • pp.1-8
    • /
    • 2004
  • A simple AMC (Adaptive Modulation and Coding) technique using ARQ (Automatic Repeat Request) for a MIMO (Multiple Input Multiple Output) system is proposed which does not require the additional feedback. In addition, the proposed AMC technique is different from the conventional technique in the aspect of considering the MCS (Modulation and Coding Scheme) level from the previous packet. The proposed technique can discard fewer amounts of unsuitable packets than the conventional technique. In the proposed system not only same rate control method for transmit antennas but also individual rate control method can be applied. The performance of the proposed technique is verified under a MIMO-OFDM (Orthogonal Frequency Division Multiplexing) system based on WLAN (Wireless Local Area Network), IEEE 802.11a. The results of the computer simulation show that a MIMO system with the proposed technique achieves higher throughput than one with a fixed transmission rate.

Automated Test Data Generation based on Executable Object Codes (실행가능 목적 코드를 기반으로 하는 자동 테스트 데이터 생성)

  • Chung, In-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.189-197
    • /
    • 2012
  • It is usual for test data generation to be performed using either high-level specifications or source codes written in high-level programming languages. In certain circumstances, however, such information is not always available. This paper presents a technique that generates test data based on executable object codes. The proposed technique makes use of a very simple function minimization technique without sophisticated object code analysis and produces test data dynamically. We have conducted a simple experiment to evaluate the effectiveness of the proposed test data generation technique with a triangle classification program to show that branch coverage can be easily achieved.

Drainage with the Seldinger Technique for Cardiac Tamponade (심장압전에 대한 Seldinger 방법을 이용한 심낭배액술 -2례 보고-)

  • Kim, Jong-Won;Park, Seo-Wan;Kim, Byeong-Jun
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1152-1156
    • /
    • 1996
  • Cardiac tamponade Is an acute, life-threatening emergency, requiring immediate decompression by a safe and simple method. The most effective method of drainage has been controversial. We experienced successful outcome for the treatment of cardiac tamponade with drainage using the Seldinger technique. The causes of the cardiac tamponade were hemopericardium after mitral and aortic valve replacement and malignant pericardial effusion due to primary lung cancer. They were treated with emergency rainage by the Seldinger technique without procedure-related complications. We believe that this technique is simple, safe for the treatment of cardiac tamponade.

  • PDF

Modified Mode Matching Technique for Analyzing Simple Expansion Chamber with Arbitrary Inlet/Outlet Location (임의의 입ㆍ출구 위치를 가지는 소음기 해석을 위한 개선된 모드일치법)

  • Kim, Bong-Jun;Jeong, Ui-Bong;Lee, Jeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1314-1322
    • /
    • 2000
  • The acoustic property of reactive type single expansion chamber can be analyzed by traditional plane wave theory. This theory can be applied in low frequency range and has good performance. But this theory can't include higher order modes, therefore another method is essential to analyze acoustic filter in high frequency range. Many researcher suggested the method that can concern higher order modes, and their methods are using mode matching technique. But there is no method that can be applied to the analysis of single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber. In this paper, the method which can analyze single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber using fundamental mode matching technique, was suggested and the predictions by this method was compared with those by the finite element method, and the influence of inlet/outlet location to acoustic performance of single expansion chamber is investigated and explained by higher order mode effects.

An Efficient Solution for Multibody Dynamics Composed of Flexible Beams (유연한 보로 구성된 다물체 동역학의 효율적인 해법)

  • 이기수;금영탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2298-2305
    • /
    • 1992
  • To obtain the convenient solution of the multibody dynamic systems composed of flexible beams, linear finite element technique is adopted and the nodal coordinates are interpolated in the global inertia frame. Mass matrix becomes an extremely simple constant matrix and the force vector also becomes extremely simple because Coriolis acceleration and centrifugal force are not required. And the elastic force is also simply computed from the moving frame attached to the material. To solve the global differential algebraic euation. an ODE technique is adopted after Lagrange multiplier is computed by the accelerated iterative technique, and the time demanding procedures such as Newton-Raphson iterations and decomposition of the big matrix are not required. The accuracy of the present solution is checked by a well-known example problem.

One injection for a great projection: a quick and simple procedure for nipple reconstruction

  • Tanini, Sara;Calabrese, Sara;Lucattelli, Elena;Russo, Giulia Lo
    • Archives of Plastic Surgery
    • /
    • v.48 no.2
    • /
    • pp.179-184
    • /
    • 2021
  • Women attach great importance to the presence of a three-dimensional nipple upon completion of the breast reconstruction process. To meet patients' expectations, nipple-areolar complex reconstruction should achieve symmetry in position, size, shape, texture, and color, as well as minimizing donor-site morbidity. However, it is well known that regardless of the reconstructive technique, loss of nipple projection can be reasonably expected. We developed and evaluated a quick, simple, and innovative technique using injectable Integra Flowable Wound Matrix to increase nipple projection after reconstruction. Twenty breast cancer patients who underwent nipple reconstruction resulting in unsatisfactory projection were enrolled in our retrospective study. Nipple projection was measured at the time of surgery and after 6 and 12 months. A visual analogue scale was used to assess patients' satisfaction. Our technique yielded reliable results in terms of the long-lasting maintenance of nipple projection. This method is high-priced, but cost-effective, since one kit may suffice for three patients. Furthermore, our patients were very appreciative of this technique as a single-step, minimally invasive, painless procedure with no reported necessity of re-intervention.

A simple technique for impression taking of teeth and functionally generated paths

  • Yamamoto, Takatsugu;Sato, Yohei;Watanabe, Hidehiko;Punj, Amit;Abe, Minoru;Momoi, Yasuko;Ohkubo, Chikahiro
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.9.1-9.6
    • /
    • 2018
  • The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF