• 제목/요약/키워드: SimPowerSystems

검색결과 273건 처리시간 0.034초

Diagnostic and Active Filtering of Harmonics Generated by Compact Fluorescent Lamps

  • Moulahoum, Samir;Houassine, Hamza;Kabache, Nadir
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.162-168
    • /
    • 2014
  • Use of nonlinear loads, such as power converters, fluorescent lamps and adjustable speed motor drives, is expected to grow rapidly. All of these loads inject harmonic currents. This paper presents the active filtering of the harmonic distortion generated by the compact fluorescent lamps (CFL). The Instantaneous active and reactive power theory (the p-q Theory) is used to design the control of parallel active filter. The control scheme has been verified using Matlab/Simulink with SimPower Systems through a set of simulation tests under different load conditions. Also, the tuning of the active power filter is performed to improve the quality of the electrical power supply.

한국형 EMS용 온라인 전력계통해석 프로그램 개발 (THE DEVELOPMENT OF POWER SYSTEM ANALYSIS ONLINE PROGRAMS FOR THE KOREAN EMS)

  • 이욱화;조윤성;윤상윤;이진;허성일;김선구;이효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.9-10
    • /
    • 2008
  • 전력IT 국책과제로 진행되는 한국형 EMS용 계통해석 프로그램 개발의 1단계 성과로는 온라인 토폴로지 프로세서, 상태추정, 휴전계획 등이며 스터디로 급전원 조류계산 등이다. 2년간에 걸친 개발 과정을 거치고 지난 08년1월${\sim}$08년4월까지 목천 한국전력거래소 후비센타에서 온라인 계통 데이터을 이용하여 다양한 실증시험, 특히 한국전력거래소의 급전원 입회시험까지 완료된 상태이다. 1단계로 개발된 프로그램 중 토폴로지, 상태추정, 휴전계획 등 프로그램 및 실증시험 결과를 중심으로 기술하고 있다.

  • PDF

UPFC Performance Control in Distribution Networks for DG Sources in the Islanding

  • Fandawi, Ahmed;Nazarpour, Daryoosh
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.303-309
    • /
    • 2017
  • The flexible AC transmission system (FACTS) provides a new advanced technology solution to improve the flexibility, controllability, and stability of a power system. The unified power flow controller (UPFC) is outstanding for regulating power flow in the FACTS; it can control the real power, reactive power, and node voltage of distribution networks. This paper investigates the performance of the UPFC for power flow control with a series of step changes in rapid succession in a power system steady state and the response of the UPFC to distribution network faults and islanding mode. Simulation was carried out using the MATLAB's simulink sim power systems toolbox. The results, which were carried out on a 5-bus test system and a 4-bus multi-machine electric power system, show clearly the effectiveness and viability of UPFC in rapid response and independent control of the real and reactive power flows and oscillation damping [6].

배전급 초전도 한류기 개발을 위한 Bi-2212 초전도 한류소자의 사고전류 제한 특성 (Fault current limitation characteristics of the Bi-2212 bulk coil for distribution-class superconducting fault current limiters)

  • 심정욱;김혜림;임성우;현옥배;이해근;박권배;김호민;이방욱;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.639-640
    • /
    • 2006
  • We investigated fault current limitation characteristics of the resistive superconducting fault current limiter(SFCL) which consisted of a Bi-2212 bulk coil and a shunt coil. The Bi-2212 bulk coil and the shunt coil were connected in parallel. The Bi-2212 bulk coil was placed inside the shunt coil to induce field-assisted quench. The fault test was conducted at an input voltage of 200 $V_{rms}$ and fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$. The fault conditions were asymmetric and symmetric, and the fault period was 5 cycles. The test results show that the SFCL successfully limited the fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$ to below $5.5{\sim}6.9kA_{peak}$ within $0.64{\sim}2.17$ msec after the fault occurred. Limitation was faster under symmetric fault test condition due to the larger change rate of current. We concluded that the speed of fault current limitation was determined by the speed of current rise rather than the amplitude of a short circuit current. These results show that the Bi-2212 bulk coil is suitable for distribution-class SFCLs.

  • PDF

BSCCO 초전도 한류기의 동시퀜치 및 내력 시험 (Equal Quench and Endurance Test of the BSCCO Superconducting Fault Current Limiter)

  • 심정욱;박권배;이방욱;오일성;임성우;김혜림;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.933-934
    • /
    • 2007
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) based on BSCCO-2212 bulk coils. Each bulk coils of the SFCL was designed to have the rated voltage of 220 $V_{rms}$ and the critical current($I_C$) of 320$\sim$340 A at 77K. Ten components in series, make the SFCL having the rated voltage of 2.2 $kV_{rms}$ for equal quench test. The fault test was conducted at an input voltage of 2.2 $kV_{rms}$ and fault current of 25 $kA_{rms}$. In addition, we examined the endurance characteristics for all bulk coils through repeat fault test. Test results shows that the SFCL successfully limited the fault current of 25$kA_{rms}$ to below $7{\sim}8kA_{p}$ within minimum 1.1msec after fault occurred. All bulk coils quenched together upon faults and shared the rated voltage evenly. The endurance test results show an equivalent among repeat fault test. During the quench process, average temperature of all bulk coils did not exceed 250 K, and the SFCL was totally safe during the whole operation.

  • PDF

몽골의 심부 지열에너지 자원과 지열발전에 관한 연구 (A Study on Deep Geothermal Energy and Potential of Geothermal Power Generation in Mongolia)

  • 한정상;윤운상;김영식;한찬;박유철;목종구
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-11
    • /
    • 2012
  • Mongolia has three(3) geothermal zones and eight(8) hydrogeothermal systems/regions that are, fold-fault platform/uplift zone, concave-largest subsidence zone, and mixed intermediate-transitional zone. Average temperature, heat flow, and geothermal gradient of hot springs in Arhangai located to fold-fault platform/uplift zone are $55.8^{\circ}C$, 60~110 mW/m2 and $35{\sim}50^{\circ}C/km$ respectively and those of Khentii situated in same zone are $80.5^{\circ}C$, 40~50 mW/m2, and $35{\sim}50^{\circ}C/km$ separately. Temperature of hydrothermal water at depth of 3,000 m is expected to be about $173{\sim}213^{\circ}C$ based on average geothermal gradient of $35{\sim}50^{\circ}C/km$. Among eight systems, Arhangai and Khentii located in A type hydrothermal system, Khovsgol in B type, Mongol Altai plateau in C type, and Over Arhangai in D type are the most feasible areas to develop geothermal power generation by Enhanced Geothermal System (EGS). Potential electric power generation by EGS is estimated about 2,760 kW at Tsenher, 1,752 kW at Tsagaan Sum, 2,928 kW at Khujir, 2,190 kW at Baga Shargaljuut, and 7,125 kW at Shargaljuut.

풍력발전단지의 효율적 운영을 위한 퍼지로직 기반 주파수 제어기 설계 (A Design for a Fuzzy Logic based Frequency Controller for Efficient wind Farm Operation)

  • 김세윤;김성호
    • 제어로봇시스템학회논문지
    • /
    • 제20권2호
    • /
    • pp.186-192
    • /
    • 2014
  • Recently wind energy penetration into power systems has increased. Wind power, as a renewable energy source, plays a different role in the power system compared to conventional power generation units. As long as only single and small wind power units are installed in the power system, wind power does not influence power system operation and can easily be integrated. However, when wind power penetration reaches a significantly high level and conventional power production units are substituted, the impact of wind power on the power system becomes noticeable and must be handled. The connection of large wind turbines and wind farms to the grid has a large impact on grid stability. The electrical power system becomes more vulnerable to and dependent on wind energy production, and therefore there is an increased concern about the large wind turbines impact on grid stability. In this work, a new type of fuzzy logic controller for the frequency control of wind farms is proposed and its performance is verified using SimWindFarm toolbox which was developed as part of the Aeolus FP7 project.

광대역 전력선 통신을 이용한 스마트 홈 네트워크 구성에 관한 연구 (Smart Home Network System Using the Broadband Power Line Communication(BPLC))

  • 양현창;심귀보
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2005년도 추계학술대회 학술발표 논문집 제15권 제2호
    • /
    • pp.87-90
    • /
    • 2005
  • The Intelligent Home provides convenient and comfortable living environment by performing automatic control, heating and air-conditioning, ventilation, home appliances control, home robot control, energy management, visitor management security management, internet, heath state monitoring, etc. through wired/ wireless network and device in the household. Along with the presentation of the features of economical broadband power line communication in the network configuration for new and old houses, its improvement method is proposed.

  • PDF

Development of Planetary Reduction Motor with Mechanical Power Monitoring and Network Capability

  • Jang In-Hun;Sim Kwee-Bo
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권3호
    • /
    • pp.359-364
    • /
    • 2006
  • This article describes the useful way to measure the torque and RPM of the geared motor. For this we have made the planetary geared reduction motor including 2 Hall sensors in it and the monitoring system. The monitoring system displays the sensing values (torque, rpm) and the calculated value (power) and it also has the network capability using the Bluetooth protocol. We will show that our solution is much more inexpensive and simple method to measure torque and rpm than before.

Modeling and Simulation using Simulink and SimPowerSystem of optimized HTS FCL location in a Smart Grid having a Wind Turbine connected with the grid

  • Khan, Umer-Amir;Lee, Sang-Hwa;Seong, Jae-Kyu;Lee, Bang-Wook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-20
    • /
    • 2010
  • A considerable amount of research material discussing designs and properties of High Temperature Superconducting Fault Current Limiter (HTS FCL) is available. However, a shortage of research concerning positioning of HTS FCL in power grid is felt. In this paper a feasibility study of HTS FCL positioning in Smart Grid through simulation analysis is carried out. A complete power network (including generation, transmission and distribution) is modeled in Simulink / SimPowerSystems. A generalized HTS FCL is also designed by integrating Simulink and SimPowerSystem blocks. The distribution network of the model has a wind turbine attached to it forming a micro grid. Three phase fault have been simulated along with placing FCL models at key points of the distribution grid. It is observed that distribution grid, having distributed generation sources attached to it, must not have a single FCL located at the substation level. Optimized HTS FCL location regarding the best fault current contribution from wind turbine has been determined through simulation analysis.