• 제목/요약/키워드: Significant peak

검색결과 2,040건 처리시간 0.023초

목 안정화와 호흡 재교육 운동이 만성 뇌졸중 환자의 목 깊은 굽힘근육의 두께, 노력성 폐활량과 최대 기침 유량에 미치는 효과 (Effects of the Neck Stabilizing Exercise Combined With the Respiratory Reeducation Exercise on Deep Neck Flexor Thickness, Forced Vital Capacity and Peak Cough Flow in Patients With Stroke)

  • 이명효;황보각
    • 한국전문물리치료학회지
    • /
    • 제22권1호
    • /
    • pp.19-29
    • /
    • 2015
  • Impaired respiratory function is common in patients with stroke. The purpose of this study were to investigate the effectiveness of exercises and to assess forced vital capacity and peak cough flow after completion of neck stabilizing and respiratory reeducation exercises (combining diaphragmatic breathing and pursed-lip breathing exercises). The 45 participants were randomly assigned to an experimental group 1 ($n_1=15$), experimental group 2 ($n_2=15$), and a control group ($n_3=15$). All subjects performed conservative physical therapy for 30 minutes. Experimental group 1 undertook the neck stabilizing exercise and the respiratory reeducation exercise. Experimental group 2 undertook the respiratory reeducation exercise. Additional exercise did not exceed 30 minutes, five times a week for six weeks. The subjects were assessed for deep neck flexor thickness and breathing function (forced vital capacity, forced expiratory volume at one second, forced expiratory volume at one second/forced vital capacity, peak expiratory flow, and manual assisted peak cough flow) at pre-post value. The results of this study were as follows. Experimental group 1 showed a significant increase only in deep neck flexor thickness change rate (p<.05). All groups showed significant increases in forced vital capacity, forced expiratory volume at one second, and peak expiratory flow in pre-post measurement (p<.05). Experimental groups 1 and 2 showed an increase in manual assisted peak cough flow in pre-post measurement (p<.05). There was no significant difference between experimental group 1 and experimental group 2, but experimental group 1 improved more than experimental group 2 in respiratory function as a whole. In conclusion, these findings suggest that the neck stabilizing exercise in combination with the respiratory reeducation exercise can improve forced vital capacity and peak cough flow in patients with stroke.

뒤시엔느 근 이영양증 환자에서 기능 수준과 측정 자세에 따른 최대호기유량, 1초간노력성호기량 및 최대기침유량의 변화 (Changes in Peak Expiratory Flow, Forced Expiratory Volume in 1 Second and Peak Cough Flow Related to Functional Level and Measurement Position in Patients With Duchenne Muscular Dystrophy)

  • 김기송;신헌석
    • 한국전문물리치료학회지
    • /
    • 제16권3호
    • /
    • pp.1-8
    • /
    • 2009
  • It is important to find the effective position for cough and sputum clearance in respiratory physical therapy. The purpose of this study was to compare the changes in peak expiratory flow (PEF), forced expiratory volume in 1 second ($FEV_1$), and peak cough flow (PCF) related to functional level and measurement position in patients with Duchenne muscular dystrophy. Twenty one subjects were classified into three functional levels, and measurements was undertaken in three different measurement positions (upright sitting, $45^{\circ}$ reclining and supine). Vitalograph PEF/FEV DIARY was used to measure PEF and $FEV_1$, and Ferraris Pocket Peak was used to measure PCF. Mixed two-way analysis of variance and Bonferroni post-hoc test were used for statistical analysis. The results of the study were as follows: 1) Significant main effects for measurement position were found. 2) PEF was the highest in upright sitting, followed by $45^{\circ}$ reclining, and supine in order. 3) $FEV_1$ in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 4) PCF in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 5) No significant main effects for functional level were found in PEF, $FEV_1$, and PCF. 6) No significant functional level by measurement position interactions were found in PEF, $FEV_1$, and PCF. Therefore, it is concluded that upright sitting and $45^{\circ}$ degree reclining positions are recommended for effective cough and sputum clearance.

  • PDF

Comparison of vertical ground reaction forces between female elderly and young adults during sit-to-stand and gait using the Nintendo Wii Balance Board

  • Lim, Ji Young;Yi, Yoonsil;Jung, Sang Woo;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권4호
    • /
    • pp.179-185
    • /
    • 2018
  • Objective: The purpose of this study was to analyze and compare vertical ground reaction forces during sit to stand (STS) and gait between female elderly and young individuals using the Wii Balance Board (WBB). Design: Cross-sectional study. Methods: Fifty-one female elderly people (age: $75.18{\pm}4.60years$), and 13 young people (age: $29.85{\pm}3.69years$) performed the five times STS test and gait respectively on the WBB. We analyzed time (s), vertical peak (%), integral summation (Int_SUM, %), and counter variables (%) in STS and 1st peak (body weight, BW%), 2nd peak (BW%), peak minimum (BW%), time (second), center of pressure (COP) path length (mm), and Int_SUM (BW%) in gait. The independent t-test was used to assess for differences in STS, gait ability, and general characteristics between the female elderly group and young adults group. With the first and last trials excluded, the mean value was obtained from the middle three of the five trials. Results: During STS, Int_SUM and time of young adults were significantly less than of the female elderly subjects. There were no significant differences in peak and counter variables. In gait, all variables (1st peak, 2nd peak, min, time, COP_path, and Int_SUM) showed significant differences between groups (p<0.05). This study demonstrated that the validity of vertical ground reaction forces occurring during STS and gait was significant in female elderly and young adults. Conclusions: Based on the measurement of vertical ground reaction forces in STS and gait using the WBB, it is possible to clinically improve the quality of geriatric physical therapy. Further studies are necessary to examine concurrent validity of elderly patients who have undergone total hip or knee replacement.

External photoglottography, intra-oral air pressure, airflow and acoustic data on the Korean fricatives /s', s/

  • Kim, Hyunsoon;Maeda, Shinji;Honda, Kiyoshi;Crevier-Buchman, Lise
    • 말소리와 음성과학
    • /
    • 제14권3호
    • /
    • pp.11-25
    • /
    • 2022
  • From simultaneous recordings of the external photoglottography, intra-oral air pressure (Pio), airflow and acoustic data from four native Seoul Korean speakers (2 male and 2 female), we have found that the two fricatives are not significantly different in glottal opening peak and airflow peak height either word-initially or word-medially and that the duration of aspiration is significantly reduced in word-medial /s/, compared to those in word-initial /s/, not in /s'/. We have also found that the duration of a high Pio plateau is significantly longer in /s/ than in /s'/ both word-initially and word-medially and that airflow resistance (R=Pio/U) at the onset and offset of a Pio plateau and at the time of airflow peak height is significantly higher in /s'/ than in /s/ across the contexts. However, the differences in Pio peak and F0 are not significant. In addition, the transition time to reach airflow peak height from the offset of a Pio plateau is found to be significantly longer in /s/ than /s'/ in both word-initial and word-medial positions. No significant differences in glottal opening peak and airflow peak height confirm that /s/ is specified as [-spread glottis] like /s'/. As for the other significant differences, we propose that /s/ is [-tense], and /s'/ [+tense].

정상성인의 견관절 우성 근력과 비우성 근력 비교 연구 - Cybex II + Isokinetic Dynamometer를 이용한 평가를 기준으로 - (The Comparion of study Isokinetic Evalution between shoulder muscles Dominant and Non-dominant in the Normal adults)

  • 문성기
    • The Journal of Korean Physical Therapy
    • /
    • 제11권1호
    • /
    • pp.111-119
    • /
    • 1999
  • The object of study who healthufl thirty persons have been enforced Isokinetic exercise of non-dominant muscular strength. The next same that each dominant muscular strength and non-dominant strength, peak torque and total work have been comparative analysis 1, Shoulder muscles comparion increase peak torque at low speed from pretraining Isokinetic exercise of non-dominant strength side to ten week of post-training.. Flexor and extensor come out high and statistically significant 6, 8, 10 week than pretraining. Adductor and abductor come out high and statistically significant 4, 6, 8. 10 week then pre-training, Internal rotator and external rotator come out statistically significant 2, 4, 6, 8, 10 week then pre-ttraining. 2. Shoulder muscles comparion increase peak torque at high speed from pre-training Isokinetic execise of non-dominant strenght side to ten week of post-training. Flexor and extensor come out high and statistically significant 4, 6, 8, 10 week then pie-training. Adductor and abductor come out high and statistically significant 2, 4, 6, 8, 10 week than pre-training. Futernal rotator and external rotator come out statistically significant 4. 6, 8, 10 week than pre-training.

  • PDF

Program Cache Busy Time Control Method for Reducing Peak Current Consumption of NAND Flash Memory in SSD Applications

  • Park, Se-Chun;Kim, You-Sung;Cho, Ho-Youb;Choi, Sung-Dae;Yoon, Mi-Sun;Kim, Tae-Yun;Park, Kun-Woo;Park, Jongsun;Kim, Soo-Won
    • ETRI Journal
    • /
    • 제36권5호
    • /
    • pp.876-879
    • /
    • 2014
  • In current NAND flash design, one of the most challenging issues is reducing peak current consumption (peak ICC), as it leads to peak power drop, which can cause malfunctions in NAND flash memory. This paper presents an efficient approach for reducing the peak ICC of the cache program in NAND flash memory - namely, a program Cache Busy Time (tPCBSY) control method. The proposed tPCBSY control method is based on the interesting observation that the array program current (ICC2) is mainly decided by the bit-line bias condition. In the proposed approach, when peak ICC2 becomes larger than a threshold value, which is determined by a cache loop number, cache data cannot be loaded to the cache buffer (CB). On the other hand, when peak ICC2 is smaller than the threshold level, cache data can be loaded to the CB. As a result, the peak ICC of the cache program is reduced by 32% at the least significant bit page and by 15% at the most significant bit page. In addition, the program throughput reaches 20 MB/s in multiplane cache program operation, without restrictions caused by a drop in peak power due to cache program operations in a solid-state drive.

급속 압축장치(RCM)의 압축 조건에 따른 최대 압력 변화에 관한 실험적 연구 (Experimental Study on Peak-Pressure Variation Due to Compression by Using RCM)

  • 김혜민;김학영;백승욱
    • 대한기계학회논문집B
    • /
    • 제35권2호
    • /
    • pp.197-204
    • /
    • 2011
  • RCM(Rapid Compression Machine)은 엔진 내부의 복잡한 연소현상을 연구하는 데 적합한 장치이다. 엔진의 연구를 위해서는 내부의 최대압력을 측정하는 것이 중요하다. 그 이유는 최대압력이 내부연료의 연소특성에 큰 영향을 끼치기 때문이며, 연소실 내부의 최대온도가 최대 압력에 의해 추정되기 때문이다. 그러나 최대압력은 실린더 벽면과의 열전달로 인해 정량적으로 계산하기 어려우며 보통 실험적인 방법을 통해 측정하고 있다. 본 연구를 통해 RCM의 구동시간에 따른 연소실의 최대압력과의 관계를 실험적으로 확인하고, 실험결과를 바탕으로 최대압력과 구동시간에 관한 일반적인 공식을 도출한다.

Characteristics of long-period swells measured in the near shore regions of eastern Arabian Sea

  • Glejin, Johnson;Kumar, V. Sanil;Amrutha, M.M.;Singh, Jai
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권4호
    • /
    • pp.312-319
    • /
    • 2016
  • Measured wave data covering two years simultaneously at 3 locations along the eastern Arabian Sea reveals the presence of long-period (peak wave period > 18 s) low-amplitude waves (significant wave height < 1 m) and the characteristics of these waves are described in this article. In a year, 1.4-3.6% of the time, the low-amplitude long-period swells were observed, and these waves were mainly during the nonmonsoon period. The wave spectra during these long-period swells were multi-peaked with peak wave period around 18.2 s, the secondary peak period around 13.3 s and the wind-sea peak period at 5 s. The ratio of the spectral energy of the wind-sea peak and the primary peak (swell) was slightly higher at the northern location (0.2) than that at the southern location (0.15) due to the higher wind speed present at the northern location.

도시화 유역에서의 홍수 유출 특성 (Flood Runoff Characteristics in Urbanized Basin)

  • 한국희;이길춘
    • 물과 미래
    • /
    • 제29권3호
    • /
    • pp.153-161
    • /
    • 1996
  • 최근에 도시화 된 산본천 유역을 대상으로 한 유출 해석이다. 실측한 각종 자료를 유출해석 모형인 ILLUDAS를 이용하여 도시화에 따른 첨두유량과 총유출량의 연구를 분석하였다. 도시하천에서 첨두유량의 증가는 도시화에 따른 하정비가 가장 큰 영향이 있는 것으로 판단된다. 첨두유량은 강우 지속시간이나 재현기간에 따라 조도계수 n=0,04일 경우에 최대 10%까지, n=0.015일 경우는 7~16%이었으며, 또한 자연하도(n=0.04)에서 계획하도(n=0.015)로 변화하면 첨두유량은 51~158%까지 큰 폭의 증가를 보였다. 일반적으로 호우시 홍수첨두유량은 증가하지만 도시유역의 경우는 배수계통의 정비로 유속이 증가하면서 하천 수위는 오히려 감소하는 것으로 나타났다.

  • PDF

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.