• Title/Summary/Keyword: Signal-to-Noise-Ratio(SNR)

Search Result 1,135, Processing Time 0.03 seconds

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF

Sputtering방식을 이용한 Indium Thin oxide박막의 넓이에 따른 X-ray 검출기 특성 연구

  • Kim, Dae-Guk;Sin, Jeong-Uk;O, Gyeong-Min;Kim, Seong-Heon;Lee, Yeong-Gyu;Jo, Seong-Ho;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.321-322
    • /
    • 2012
  • 의료용 방사선 장비는 초기의 아날로그 방식의 필름 및 카세트에서 진보되어 현재는 디지털 방식의 DR (Digital Radiography)이 널리 사용되며 그에 관한 연구개발이 활발히 진행되고 있다. DR은 크게 간접방식과 직접방식의 두 분류로 나눌 수 있는데, 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 X선을 가시광선으로 전환하고, 이를 Photodiode와 같은 광소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말하며, 직접 방식은 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 고전압을 인가한 형태를 취하고 있는 가운데, X선이 조사되면 일차적으로 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이들은 광도전체 양단의 인가되어 있는 전기장에 의해 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 Active matrix array을 통해 방사선을 검출하는 방식이다. 본 연구에서는 직접방식 X-ray 검출기에서 활용되는 a-Se을 ITO (Indium Thin oxide) glass 상단에 Thermal evaporation증착을 이용하여 두께 $50{\mu}m$, 33 넓이로 증착 시킨 다음, a-Se상단에 Sputtering증착을 이용하여 ITO를 11 cm, 22 cm, $2.7{\times}2.7cm$ 넓이로 증착시켜 상하부의 ITO를 Electrode로 이용하여 직접방식의 X-ray검출기 샘플을 제작하였다. 제작 과정 중 a-Se의 Thermal evaporation증착 시, 저진공 $310^{-3}_{Torr}$, 고진공 $2.210^{-5}_{Torr}$에서 보트의 가열 온도를 두 번의 스텝으로 나누어 증착 시켰다. 첫 번째 스텝 $250^{\circ}C$, 두 번째 스텝은 $260^{\circ}C$의 조건으로 증착하여 보트 내의 a-Se을 남기지 않고 전량을 소모할 수 있었으며, 스텝간의 온도차를 $10^{\circ}C$로 제어하여 균일한 박막을 형성 할 수 있었다. Sputtering증착 시, 저진공 $2.510^{-3}$, 고진공 $310^{-5}$에서 Ar, $O_2$를 사용하여 100 Sec간 플라즈마를 생성시켜 ITO를 증착하였다. 제작된 방사선 각각의 검출기 샘플 양단의 ITO에 500V의 전압을 인가하고, 진단 방사선 범위의 70 kVp, 100 mA, 0.03 sec 조건으로 X-ray를 조사시켜 ITO넓이에 따른 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 측정결과 민감도(Sensitivity)는 X-ray샘플의 두께에 따른 $1V/{\mu}m$ 기준 시, 증착된 ITO의 넓이가 11 cm부터 22 cm, $2.7{\times}2.7cm$까지 각각 $7.610nC/cm^2$, $8.169nC/cm^2$, $6.769nC/cm^2$로 22 cm 넓이의 샘플이 가장 높은 민감도를 나타내었으나, 암전류(Dark current)는 $1.68nA/cm^2$, $3.132nA/cm^2$, $5.117nA/cm^2$로 11 cm 넓이의 샘플이 가장 낮은 값을 나타내었다. 이러한 데이터를 SNR (Signal to Noise Ratio)로 합산 하였을 시 104.359 ($1{\times}1$), 60.376($2{\times}2$), 30.621 ($2.7{\times}2.7$)로 11 cm 샘플이 신호 대 별 가장 우수한 효율을 나타냄을 알 수 있었다. 따라서 ITO박막의 면적이 클수록 민감도는 우수하나 그에 따른 암전류의 증가로 효율이 떨어짐을 검증 할 수 있었으며, 이는 ITO면적이 넓어짐에 따른 저항의 증가로 암전류에 영향을 끼침을 할 수 있었다. 본 연구를 통해 a-Se의 ITO 박막 면적에 따른 전기적 특성을 검증할 수 있었다.

  • PDF