• Title/Summary/Keyword: Signal variation

Search Result 1,117, Processing Time 0.023 seconds

Channel Distortion Effects on a BPSK DS/SS and a QPSK DS/SS Signal Demodulation (BPSK DS/SS외 QPSK DS.SS 신호 복호에서 채널 왜곡의 영향)

  • Park, Jin-Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.8
    • /
    • pp.867-873
    • /
    • 1988
  • The degradation due to channel distortion in a quadrature modulation system from the ideal constant values over the bandwidth of a direct sequence spread spectrum signal are considered. Through using series expansion for the channel gain and phase response, the degradation in the correlator output at the receiver is found as a function of the parameters involved , including phase error, delay error, linear gin variation, quadratic gain variation, and quadratic phase variation.

  • PDF

Experimental Study of Vehicle Signal Change for Generator Voltage Variation (자동차 발전기 전압변동에 따른 차량 신호 변화에 대한 실험적 연구)

  • Ko, Kwang-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.5
    • /
    • pp.235-240
    • /
    • 2018
  • The generator of an automobile supplies electric voltage and current for various electric components. The supplied voltage can be changed by sudden variation of the electric load. The voltage was controlled by independent power supply in the study. The TPS and APS signal was changes as the voltage of the power supply. The ECU output voltage and OBD signal voltage was changed also as the variance of the power supply.

Spatiotemporal Location Fingerprint Generation Using Extended Signal Propagation Model

  • Kim, Hee-Sung;Li, Binghao;Choi, Wan-Sik;Sung, Sang-Kyung;Lee, Hyung-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.789-796
    • /
    • 2012
  • Fingerprinting is a widely used positioning technology for received signal strength (RSS) based wireless local area network (WLAN) positioning system. Though spatial RSS variation is the key factor of the positioning technology, temporal RSS variation needs to be considered for more accuracy. To deal with the spatial and temporal RSS characteristics within a unified framework, this paper proposes an extended signal propagation mode (ESPM) and a fingerprint generation method. The proposed spatiotemporal fingerprint generation method consists of two algorithms running in parallel; Kalman filtering at several measurement-sampling locations and Kriging to generate location fingerprints at dense reference locations. The two different algorithms are connected by the extended signal propagation model which describes the spatial and temporal measurement characteristics in one frame. An experiment demonstrates that the proposed method provides an improved positioning accuracy.

Development of Motor, Encoder Evaluation System using High Performance DSP (고성능 DSP를 이용한 모터, 엔코더 성능평가 시스템 개발)

  • Jang, Mun-Suck;Shim, Jae-Hong;Lee, Enug-Hyuk;Choi, Sang-Bang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.77-82
    • /
    • 2009
  • In robot operation, a motor with multi-degree of freedom motion control and an encoder for motor control are needed. To perform precise motion, location, and velocity control, the operation of motor and encoder with superior performance is important. In this paper, we studied performance evaluation system that can evaluate the performance of motor and encoder. The performance of motor and encoder can be evaluated in terms of disconnection check, signal variation count, and U, V, W signal check. Disconnection check verifies signal connection between a motor and an encoder, signal variation check verifies A, B signal by counting the number of signal A, B when a motor revolves, and U, V, W signal check verifies operating direction of a motor. The result is shown at graphic LCD integrated in system, and can be checked in PC with PC communication.

  • PDF

Sea level observations at Kerguelen island in the South Indian Ocean by ARGOS satellite data (ARGOS 위성 자료를 이용한 남인도양 케르겔른섬의 해수면 조사)

  • 윤홍주;김영섭;서애숙;정효상;안명환
    • Proceedings of the KSRS Conference
    • /
    • 2000.04a
    • /
    • pp.13-18
    • /
    • 2000
  • We observed sea level variation of the long time at Kerguelen island in the South Indian Ocean with ARGOS data and meteorological data during about 1 year(May 1993~March 1994) through using filter, spectral analysis, coherency and phase, and found characteristics for the two oceanic signal levels(detided oceanic signal level, h$_{detided}$ and seasonal oceanic level, h$_{corr.ib}$). The forms of variations are very well agreed to between ARGOS data and meteorological data for atmospheric pressure in the observed periods. The seasonal difference of sea level between Summer and Winter is about 1.6cm. Both the detided oceanic signal level(h$_{detided}$) variation and the inverted barometer level(h$_{ib}$) variation have a strong correlation for T>1day period bands. Characteristics of h$_{detided}$ variation are decided not by the influence of any meteorological distributions (pressure, winds, etc), but the influence of another factors(temperature, salinity, etc.) for T>2days periods bands. h$_{corr.ib}$ plays an very important role of sea level variation of the long time term(especially T>about 180days period bands).

  • PDF

A Study on Obstruction of Radio Waves by Trees on the Road (도로변 가로수로 인한 전자파의 장애에 관한 연구)

  • 오일덕
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.6
    • /
    • pp.1149-1157
    • /
    • 1994
  • In this case of the mobile communication of vehicles with satellite, the signal at attenuation is due to roadside trees. To analyze this signal attenuation, a roadside tree was modeled as different obstacles of rectangular type and then using Fresnel and Kirchhoff diffraction theory, a formula was derived for signal intensity variation caused by the roadside tree model. The signal attenuation of a roadside tree model was obtained by numerical analysis with variation of the elevation angle, the position and distance between a receiver and a transmitter, and these were compared with experimental results. The results of comparison between theoretical and experimental values show, as expected, the good agreement of the signal attenuation trend.

  • PDF

Research on Synthesis of Radiation Noise from Moving Target (이동하는 표적의 방사소음 합성기법 연구)

  • 배재휘
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 2000
  • A target signal simulation method for passive sonar systems is introduced. The method uses multirate signal processing techniques to simulate moving target signals in the multi-path sound propagation environment by introducing Lloyd's mirror and Doppler effect. Time and frequency variation of target signal due to the target maneuvering is also considered to provide realistic ship signatures in the LOFAR gram so that the simulated target is used for sonar operator training. Synthesized target characteristics is analyzed and compared with real target signal in terms of interference pattern and frequency variation in the LOFAR gram.

  • PDF

Analysis on the special quantitative variation of dot model by the position transform

  • Kim, Jeong-lae;Kim, Kyung-seop
    • International Journal of Advanced Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.67-72
    • /
    • 2017
  • Transform variation technique is constituted the vibration status of the flash-gap recognition level (FGRL) on the distribution recognition function. The recognition level condition by the distribution recognition function system is associated with the scattering vibration system. As to search a position of the dot model, we are consisted of the distribution value with character point by the output signal. The concept of recognition level is composed the reference of flash-gap level for variation signal by the distribution vibration function. For displaying a variation of the FGRL of the maximum-average in terms of the vibration function, and distribution position vibration that was the a distribution value of the far variation of the $Dis-rf-FA-{\alpha}_{MAX-AVG}$ with $5.74{\pm}1.12$ units, that was the a distribution value of the convenient variation of the $Dis-rf-CO-{\alpha}_{MAX-AVG}$ with $1.64{\pm}0.16$ units, that was the a distribution value of the flank variation of the $Dis-rf-FL-{\alpha}_{MAX-AVG}$ with $0.74{\pm}0.24$ units, that was the a distribution value of the vicinage variation of the $Dis-rf-VI-{\alpha}_{MAX-AVG}$ with $0.12{\pm}0.01$ units. The scattering vibration will be to evaluate at the ability of the vibration function with character point by the distribution recognition level on the FGRL that is showed the flash-gap function by the recognition level system. Scattering recognition system will be possible to control of a function by the special signal and to use a distribution data of scattering vibration level.

Sea Level Variations at Kerguelen Island in the South Indian Ocean by the Satellite Data(ARGOS) and Meteorological Data(METEO)

  • Yoon, Hong-Joo
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.2
    • /
    • pp.117-133
    • /
    • 2000
  • We studied the sea level variations at Kerguelen island in the South Indian Ocean with ARGOS data and meteorological data during about 1 year(May 1993~April 1994) through using filter, spectral analysis, coherency and phase, and found characteristics for the two oceanic signal levels(detided oceanic signal level, h$_{detided}$ and seasonal oceanic level, h$_{corr.ib}$). The forms of atmospheric pressure variations are good agreed to between ARGOS data and meteorological data in the observed periods. This Kerguelen area shows the inflow of an air temperature(gain of a radiant heat) into the sea water and the stagnation of high atmospheric pressure bands in summer, and the outflow of a sea water temperature(loss of sensible and latent heat) toward the atmosphere and the stagnation of low atmospheric pressure bands in winter. The seasonal difference of sea level between summer and winter is about 1.6cm. Both the detided oceanic signal level(h$_{detided}$) variation and the inverted barometer level(h$_{ib}$) variation have a strong correlation for T>1day period bands. The characteristics of h$_{detided}$ variation are not decided by the influence of any meteorological distributions (atmospheric pressure), but the influence of other factors(bottom water temperature) for T>2days periods bands. h$_{corr.ib}$ plays a very important role of sea level variation in the observed periods (especially T>about 180days period bands).

Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change (커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현)

  • Jeong, Do-Un;Bae, Jin-Woo;Shon, Jung-Man;Yae, Su-Yung;Choi, Byeong-Cheol;Nam, Ki-Gon;Kim, Cheol-Han;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.