• Title/Summary/Keyword: Signal transfer method

Search Result 317, Processing Time 0.034 seconds

Design of controller in control system with two degrees of freedom by the normal method (정규화법에 의한 2자유도 제어계에서 제어기의 설계)

  • Ha, Hong-Gon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.1
    • /
    • pp.56-61
    • /
    • 2011
  • Many control techniques have been proposed in order to improve the control performance of the control system. The degree of freedom on control in the control system is decided by the number of the closed-loop transfer function which can adjust independently. The controller design scheme with two degrees of freedom(TDOF) is extensively used for securing the good control performance to trace a desired value and reject disturbance. In this paper, PID controller is used by controller with TDOF and the design method for control system with TDOF is proposed by the normal method. Using the coefficients of the transfer function of the plant, the transfer function of the control system is normalized by the proposed design method and the parameters of the controller are determined. The control system with the TDOF is constructed by using this method. Through the simulation results, the usefulness of the proposed algorithm is proved.

An Enhancement Method of Document Restoration Capability using Encryption and DnCNN (암호화와 DnCNN을 활용한 문서 복원능력 향상에 관한 연구)

  • Jang, Hyun-Hee;Ha, Sung-Jae;Cho, Gi-Hwan
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.2
    • /
    • pp.79-84
    • /
    • 2022
  • This paper presents an enhancement method of document restoration capability which is robust for security, loss, and contamination, It is based on two methods, that is, encryption and DnCNN(DeNoise Convolution Neural Network). In order to implement this encryption method, a mathematical model is applied as a spatial frequency transfer function used in optics of 2D image information. Then a method is proposed with optical interference patterns as encryption using spatial frequency transfer functions and using mathematical variables of spatial frequency transfer functions as ciphers. In addition, by applying the DnCNN method which is bsed on deep learning technique, the restoration capability is enhanced by removing noise. With an experimental evaluation, with 65% information loss, by applying Pre-Training DnCNN Deep Learning, the peak signal-to-noise ratio (PSNR) shows 11% or more superior in compared to that of the spatial frequency transfer function only. In addition, it is confirmed that the characteristic of CC(Correlation Coefficient) is enhanced by 16% or more.

Active noise control with on-line adaptive algorithm in a duct system (덕트에서 온라인 적응 알고리듬을 이용한 능동소음제어)

  • Kim, Heung-Seob;Hong, Jin-Seok;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.8
    • /
    • pp.1332-1338
    • /
    • 1997
  • In the case of the transfer function for the secondary path is dependent on time, the on-line method which can model it is continuously must be applied to the active noise control technique. And the adaptive random noise technique among the on-line methods is effective in the narrow-band control. In this method, the signal to noise ratio between random noise for modeling and primary noise is low. Therefore, the estimations of transfer function will be prone to inaccuracies and the convergence time will be too long. Such imperfections will have an influence upon the performance of an active noise controller. In this study, t enhance the signal to noise ratio, the on-line method that is combined the conventional adaptive random noise technique and the adaptive line enhancer, is proposed. By using proposed on-line method, a rigorous system identification and control of primary noise have been implemented.

Control-to-output Transfer Function of the Open-loop Step-up Converter in CCM Operation

  • Wang, Faqiang;Ma, Xikui
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1562-1568
    • /
    • 2014
  • Based on the average method and the geometrical technique to calculate the average value, the average model of the open-loop step-up converter in CCM operation is established. The DC equilibrium point and corresponding small signal model is derived. The control-to-output transfer function is presented and analyzed. The theoretical analysis and PSIM simulations shows that the control-to-output transfer function includes not only the DC input voltage and the DC duty cycle, but also the two inductors, the two energy-transferring capacitors, the switching frequency and the load. Finally, the hardware circuit is designed, and the circuit experimental results are given to confirm the effectiveness of theoretical derivations and analysis.

Weld Quality Assessment Method for Short-Circuit Mode in GMAW

  • Kim, J.M.;Yoo, C.D.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.2
    • /
    • pp.1-6
    • /
    • 2001
  • A weld quality assessment method is proposed in this work, which can be applied to the short-circuit mode in GMAW. Information about the welding signal trajectory, distribution of the signal duration at each sub-regions and short-circuit frequency is used to evaluate the weld quality. The weighted penalty, which is determined experimentally, is imposed for each abnormal signal. Performance of the proposed method is compared with the Simpson's method under the conditions of shielding gas reduction, workpiece surface contamination and joint gap in the butt and fillet welds. Although the proposed method predicts the weld quality with reasonable accuracy, further modification and extension to other metal transfer modes are needed as a further study.

  • PDF

Transfer Path Analysis of vibration and noise for medical air compressor using PAK system (PAK system 을 이용한 의료용 컴프레서의 진동.소음 전달경로 해석)

  • Kang, Kwi-Hyun;Kang, Jin-Chul;Park, Chun-Kwon;Lee, Jeong-Hwan;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.1000-1004
    • /
    • 2008
  • As performance of medical air compressor improve, the problem of noise increased. Noise is very important to medical air compressor because most of this installed inside of building. The main goal of this paper is show TPA (Transfer Path Analysis) result for contribution analysis using PAK system. Generally, the conventional TPA method consists of two steps. First, transfer functions between output sound and sources are measured by excitation experiment. Second, transferred sound in each transfer path is generated by multiplying the transfer function and the sound source signal. Then, if the output sound synthesized from all transferred sounds doesn't give good agreement with the measured output sound (i.e., the accuracies of the transfer functions are low), setting a suitable countermeasure guideline becomes difficult. For obtaining highly accurate transfer functions, eliminating correlations among transfer functions and noise included in the measured data are necessary. In the new method with PAK system, the vibration acceleration and sound signals around the sound sources and the output sound were measured simultaneously to obtain the transfer functions when compressor was operating. By applying PAK system, a highly accurate and efficient transfer path analysis method was developed that does not require an excitation experiment.

  • PDF

Dimming Control Signal Transmisson of Electronic Ballast on the Power Line and Characteristics Measurement (전력선을 이용한 전자식 안정기 조광 신호 전송과 특성 측정)

  • 이상곤;정은택;강복연;양병렬;유홍균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.4
    • /
    • pp.691-700
    • /
    • 1994
  • A power line in not so good in characteristics for communication, because it is a media to transfer the commercial electrical power, and its load noise and high frequency noise are so much. Thus, a simple method to transfer a remote control signal on the power line is studied. The already-existing method is that two signals with upper part eliminated is transmitted every N step. But the method is investigated which the transmitter sends a period signal eliminated in arbitrary phase. Thus the transmission power loss due to elimination of signal can be reduced to the minimum. To implement it, a timer calculating the time from zero-crossing point to the phase is required. The micro-controller, 87C51, precisely calculates the phase using one of two built-in timers. As a result, a remote control signal tramsmitter and receiver using a partially eliminated signal, which is better than the conventional technique using half-eliminated signal in a efficiency of power transmission, is realized, and its characteristics are analyzed.

  • PDF

A Time-Domain Approach for the Second-Order Diffraction Problem Around Circular Cylinders in Random Waves

  • YONGHWAN KIM
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.12-18
    • /
    • 2001
  • This study concentrates on the second-order diffraction problem around circular cylinders in multi-frequency waves. The method of solution is a time-domain Rankine panel method which adopts a higher-order approximation for the velocity potential and wave elevation. In the present study, the multiple second-order quadratic transfer functions are extracted from the second-order time signal generated in random waves, and the comparison with other bench-mark test results shows a good agreement. This approach is directly applicable to prediction of nonlinear forces on offshore structures in random ocean.

  • PDF

A Parameter Estimation of Time Signal and Analysis of Low Frequency Oscillation in Power Systems (시간영역에서 파라미터 추정과 전력계통의 저주파진동 해석)

  • Shim Kwan-Shik;Nam Hae-Kon;Kim Yong-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.3
    • /
    • pp.122-132
    • /
    • 2005
  • This paper presents a novel approach based on Prony method to analysis of small signal stability in power system. Prony method is a valuable tool in identifying transfer function and estimating the modal parameter of power system oscillation from measured or computed discrete time signal. This paper define the relative residue of time signal and propose the condition to select low frequency oscillation in each generator. This paper describes the application results of proposed algorithm with respect to KEPCO systems. Simulation results show that the proposed algorithm can be used as another tools of power systems analysis.

A Method for Fault detecting on Power Transmission Network by use of M-sequence Correlation

  • Nishiyama, Eiji;Kuwanami, Kenshi;Owaki, Kosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2570-2575
    • /
    • 2003
  • Monitoring a power transmission line is significant for power electric companies. In this paper, we propose a new method for detecting an fault point of power transmission line by use of M-sequence correlation technique. In this method, detecting signal is used as one or plural M-sequences ( same characteristic polynomial, including normal and reverse mark, synchronized ). In receiving point, we make same sequence with the input one and take crosscorrelation function between M-sequence and the received signal. We can see transfer fanctions of plural paths between inputs and a output taps separated from different of delay times on the crosscorrelation function, and from these transfer fanctions, so we compare them when fault occurred with in usual.

  • PDF