• 제목/요약/키워드: Signal to Noise Ratio(SNR)

검색결과 1,119건 처리시간 0.028초

MR DANTE 고속 영상에서 SNR의 개선에 관한 연구 (Improvement of SNR in DANTE Fast MR Imaging)

  • 정성택
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.87-96
    • /
    • 1997
  • A pixel profile in the conventional DANTE sequence is so poor that the excited area by DANTE sequence is a small portion of a pixel. This causes poor signal to noise ratio in DANTE image. In this paper, a frequency modulated(FM) DANTE imaging sequence is proposed to improve pixel profile in DANTE image. A DANTE pulse train is shaped by an FM function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on the sweep in FM signal. Computer simulations and experimental result obtained using a 7.0 T NMR imaging system are presented.

  • PDF

정상인과 후두폴립환자에서의 음성학적 측정 (Acoustic Measures from Normal and Vocal Polyp Patients)

  • 최홍식;장미숙;이정준
    • 대한후두음성언어의학회지
    • /
    • 제5권1호
    • /
    • pp.38-43
    • /
    • 1994
  • Though normal vocal cords show regular vibration, pathologic vocal cords show irregularity between peaks. Jitter means fluctuation in the time interval between peaks, and Shimmer means cycle to cycle variation in the amplitude of the peaks. We investigated the vocal vibration of Korean normal persons objectively. The fundamental frequency, Jitter, Shimmer and SNR(signal to noise ratio) of normal persons were compared with that of vocal Polyp Patients with CSpeech Program for the possibility of distinguishing the pathologic vocal vibration from normal. The results were as follows ; Comparing the fundamental frequency of vocal Polyp Patients with normal persons, great change was noted only in female cases. But the Jitter and Shimmer of vocal polyp patients were greater than normal significantly in both male and female cases. SNR was lower than normal in vocal polyp patients. In the conclusion, fundamental frequency, Jitter, Shimmer and SNR might be meaningful parameters distinguisuing pathologic vibration from normal.

  • PDF

Wavelet변환을 이용한 초음파 잡음신호의 제거에 관한 연구 (A Study on Suppression of Ultrasonic Background Noise Signal using wavelet Transform)

  • 박익근
    • 한국생산제조학회지
    • /
    • 제8권1호
    • /
    • pp.135-141
    • /
    • 1999
  • Recently, advance signal analysis which is called "Time-Frequency Analysis" has been developed. Wavelet and Wigner Distribution are used to the method. Wavelet transform(WT) is applied to time-frequency analysis of waveforms obtained by an ultrasonic pulse-echo technique. The Gabor function is adopted as the analyzing wavelet. Wavelet analysis method is an attractive technique for evolution of material characterization evoluation. In this paper, the feasibility of suppression of ultrasonic background noise signal using WT has been presented. These results suggest that ultrasonic background noise ginal can be suppressed and enhanced even for SNR of 20.8 dB. This property of the WT is extremely useful for the detecting flaw echos embedded in background noise.und noise.

  • PDF

이중 마이크를 사용한 보청기의 궤환 및 잡음제거 알고리즘 (A Feedback and Noise Cancellation Algorithm of Hearing Aids Using Dual Microphones)

  • 이행우
    • 한국통신학회논문지
    • /
    • 제36권7C호
    • /
    • pp.413-420
    • /
    • 2011
  • 본 논문에서는 양이 보청기의 음향궤환 및 잡음을 제거하기 위한 새로운 알고리즘을 제안한다. 이 알고리즘은 이중 마이크를 사용하여 잔차신호에서 음성신호를 제거한 후 궤환제거 필터의 계수를 갱신시킴으로써 수렴성능을 향상시킨다. 먼저 궤환제거기가 마이크 선호에서 궤환신호를 제거하고, 이어서 빔포밍 기법을 이용하여 잡음을 제거한다. 양이 보청기의 안정적 수렴을 보장하기 위해 좌측 및 우측 보청기를 분리하여 먼저 좌측 보청기를 수렴시키고 나서 그 다음 우측 보청기를 수렴시키는 과정으로 진행한다. 본 연구에서 제안한 궤환 및 잡음제거기의 성능을 검증하기 위하여 시뮬레이션 프로그램을 작성하고 모의실험을 수행하였다. 실험 결과, 제안한 적응 알고리즘을 사용하면 기존의 알고리즘을 사용하는 경우보다 궤환제거기에서 평균 14.43 dB의 SFR(Signal to Feedback Ratio), 잡음제거기에서 평균 10.19 dB의 SNR(Signal to Noise Ratio) 개선효과를 향상시킬 수 있는 것으로 확인하였다.

Location Error Analysis of an Active RFID-Based RTLS in Multipath and AWGN Environments

  • Myong, Seung-Il;Mo, Sang-Hyun;Yang, Hoe-Sung;Cha, Jong-Sub;Lee, Heyung-Sub;Seo, Dong-Sun
    • ETRI Journal
    • /
    • 제33권4호
    • /
    • pp.528-536
    • /
    • 2011
  • In this paper, we analyze the location accuracy of real-time locating systems (RTLSs) in multipath environments in which the RTLSs comply with the ISO/IEC 24730-2 international standard. To analyze the location error of RTLS in multipath environments, we consider a direct path and indirect path, in which time and phase are delayed, and also white Gaussian noise is added. The location error depends strongly on both the noise level and phase difference under a low signal-to-noise ratio (SNR) regime, but only on the noise level under a high SNR regime. The phase difference effect can be minimized by matching it to the time delay difference at a ratio of 180 degrees per 1 chip time delay (Tc). At a relatively high SNR of 10 dB, a location error of less than 3 m is expected at any phase and time delay value of an indirect signal. At a low SNR regime, the location error range increases to 8.1 m at a 0.5 Tc, and to 7.3 m at a 1.5 Tc. However, if the correlation energy is accumulated for an 8-bit period, the location error can be reduced to 3.9 m and 2.5 m, respectively.

낮은 SNR 다중 표적 환경에서의 iterative Joint Integrated Probabilistic Data Association을 이용한 표적추적 알고리즘 연구 (Study of Target Tracking Algorithm using iterative Joint Integrated Probabilistic Data Association in Low SNR Multi-Target Environments)

  • 김형준;송택렬
    • 한국군사과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.204-212
    • /
    • 2020
  • For general target tracking works by receiving a set of measurements from sensor. However, if the SNR(Signal to Noise Ratio) is low due to small RCS(Radar Cross Section), caused by remote small targets, the target's information can be lost during signal processing. TBD(Track Before Detect) is an algorithm that performs target tracking without threshold for detection. That is, all sensor data is sent to the tracking system, which prevents the loss of the target's information by thresholding the signal intensity. On the other hand, using all sensor data inevitably leads to computational problems that can severely limit the application. In this paper, we propose an iterative Joint Integrated Probabilistic Data Association as a practical target tracking technique suitable for a low SNR multi-target environment with real time operation capability, and verify its performance through simulation studies.

다중 신호원의 도래방향 추정을 위한 개선된 MVE에 관한 연구 (A Study on an Improved MVE for Estimating the Direction of Arrival of Multiple Sources)

  • 정용민;신준호;김용득
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.687-690
    • /
    • 1999
  • Many high-resolution algorithms based on the eigen-decomposition analysis of observed covariance matrix, such as MVE, MUSIC, and EVM, have been proposed. However, the resolution of spectral estimates for these algorithms is severely degraded when Signal-to-Noise Ratio (SNR) is low and arrival angles of signal are close to each other. And EVM and MUSIC is powerful for the characteristic of SNR. But have the limitation that the number of signals presented is known. While MVE is bad the characteristic of SNR. In this study, we propose a modified MVE to enhance the resolution for Direction-Of-Arrival (DOA) estimation of underwater acoustic signal. This is to remove the limitation that existing algorithms should know the information for the number of signals. Because the algorithms founded on the eigen value estimate DOA with only the noise subspace, they have the high-resolution characteristic. And then, with the method reducing the effect of the signal subspace, we are to reduce the degradation because of complementary relationship between the signal subspace and the noise subspace. This paper, with using the simulation data, we have estimated the proposed algorithms, compared it with other high-resolution algorithms. The simulation results show that the modified MVE proposed is accurate and has a better resolution even though SNR is low, under the same condition.

  • PDF

신호대잡음비의 임계값 설정에 따른 UHF 윈드프로파일러 바람벡터의 정확도 평가 (Accuracy Evaluation of UHF Wind Profiler Radar Wind Vectors by Setting a Threshold of Signal-to-Noise Ratios)

  • 김광호;김박사;김민성;강동환;권병혁
    • 한국환경과학회지
    • /
    • 제25권9호
    • /
    • pp.1241-1251
    • /
    • 2016
  • A minimum threshold for the signal to noise ratio ($SNR_{min}$) has to be set in the data processing system of wind profiler radar (WPR). The data collection rate and the accuracy of the WPR wind vector depend on the $SNR_{min}$. The WPR at Uljin is operated with an $SNR_{min}$ of 1 dB which is a relatively large threshold. We found that the accuracy and the continuity of the WPR wind vector with height were directly related to the variability of the SNR and vertical gradient of the squared refractive index. We investigated a quantitative method for determining a new $SNR_{min}$ for the WPR at Uljin and it was evaluated with radiosonde data. The accuracy and continuity of the wind vector from an SNR of less than 1 dB, began to decrease at an altitude of 3.5 km. Most of the SNR values were less than -3.5 dB in altitudes higher than 3.5 km. We retrieved high-accuracy wind vectors at altitudes over 3 km where measurements were deficient with an $SNR_{min}$ of 1 dB.

웨이브 디지털 필터의 스케일링에 관한 연구 (A Study on the Scaling in Wave Digital Filter)

  • 권희훈;김명기
    • 한국통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.27-35
    • /
    • 1987
  • 유한어장으로 인하여 디지털 필터에는 반올림한 오차의 잡음과 가산기의 오버플로 문제가 있다. 오버플로가 발생하지 않으면서 내부신호의 레벨을 가능한 최대가 되도록 바꾸기 위하여 행하는 것이 스케일링의 목적이다. 스케일링의 필요조건은 변압기를 사용하여 실현한다. 본 논문에서 오버플로를 피하면서 출력의 SNR을 극대화하는 절차를 제안하였다. 그 결과 스케일링한 경우에 오버플로가 발생하지 않으면서 SNR이 개선되었다.

  • PDF

전산화단층촬영에서 관전압과 관전류, 통계적 반복재구성법에 따른 화질과 피폭선량 (Quality of Image and Exposure Dose According to kVp, mA and Iterative Reconstruction in Computed Tomography)

  • 차상영;박재윤;이용기;김정훈;최재호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.385-392
    • /
    • 2017
  • 본 연구는 전산화단층촬영에서 관전압과 관전류에 따른 화질과 피폭선량을 연구하고 None IR과 IR (Iterative Reconstruction)의 단계에 따른 영상의 SNR(Signal to Noise Ratio)을 비교하여 영상 화질의 개선정도에 대하여 확인해보고자 하였다. Image J를 이용하여 화질을 측정한 결과 관전압의 증가에 따라 HU (Hounsfield units)와 BN(Background Noise)은 감소하였으며, 이와 반대로 SI (Signal Intensity)와 SNR, $CTDI_{vol}$ (CT dose in dex volume)은 관전압이 높아질수록 증가하였으며, BHU(Background Hounsfield Units)의 변화는 없었다. 관전류의 증가로 인해서 BN이 감소하였고, 반대로 SNR과 CTDI은 증가하였다. 또한 IR의 단계가 높아질수록 HU와 SI, BN이 낮아지고, SNR이 약 10~60% 향상됨을 알 수 있었다. 이를 토대로 임상에서 IR 적용 시 단계적 접근 방식으로 관전압과 관전류를 미세 조정하여 점차적으로 방사선량을 줄여 나가야 할 것이다.