• 제목/요약/키워드: Shut-off Valve

검색결과 53건 처리시간 0.01초

긴급차단용 안전밸브의 성능해석 (Performance Analysis of Emergency Shut-Off Safety Valve)

  • 송희용;박경암;고성호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.413-418
    • /
    • 2001
  • Emergency shut-on valve was developed to shut off natural gas at the front of a gas meter in the house. The shut-off flow rate and differential pressure of this valve was controlled by adjusting the distance between the spool and magnet. Also the spool shape was an important factor in the performance of this valve. The experimental and computational results will be useful for the design having better performance.

  • PDF

LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구 (Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder)

  • 김청균
    • 한국가스학회지
    • /
    • 제19권6호
    • /
    • pp.80-84
    • /
    • 2015
  • 본 연구에서는 기존의 차단기능형 수직식 용기밸브와 새로이 개발된 수평식 용기밸브의 몸체전고와 중량에 대한 설계 데이터를 고찰하였다. 차단기능형 수평식 용기밸브의 전고는 기존의 차단기능형 수직식 용기밸브에 비해 41~42%나 획기적으로 줄어들었다. 또한, 수평식 밸브의 몸체 무게는 기존의 차단기능형 수직식 밸브에 비해 29~40%나 줄어든 결과를 얻었다. 이러한 결과는 단지 기존의 수직식 밸브에서 밸브의 여러 가지 구성요소를 수평식으로 배열을 바꾼 구조변경 설계를 통해 확보한 것이다.

고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석 (Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility)

  • 김명철;우정재;이형섭;백종배
    • 한국안전학회지
    • /
    • 제32권4호
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

2단계 개방 연소기 산화제 개폐밸브 개발 (Development of a Two-Step Main Oxidizer Shut-off Valve)

  • 홍문근
    • 한국항공우주학회지
    • /
    • 제45권8호
    • /
    • pp.704-710
    • /
    • 2017
  • 액체로켓엔진용 연소기 산화제 개폐밸브는 단순 온 오프 개폐작동을 통해 연소기로의 산화제 공급 유무만을 제어하기 때문에, 산화제 공급 유량 조절을 통한 엔진 점화 시동 특성제어 및 최적화에 한계가 있는 반면에 2단계 개방 연소기 산화제 개폐밸브는 밸브의 부분 개방에 의해 산화제 공급 유량을 조절함으로써 엔진 점화 시동 특성을 제어할 수 있는 이점이 있다. 이에 본 논문에서는 액체로켓엔진용 2단계 개방 연소기 산화제 개폐밸브 개발을 위한 기본 설계 내용과 함께 밸브 작동성에 관한 검증시험 결과를 소개하기로 한다.

CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구 (A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

연료차단밸브의 열해석에 관한 수치적 연구 (A Numerical Study on Thermal Analysis of Fuel Shut-off Valve)

  • 백낙곤;이재윤
    • 한국추진공학회지
    • /
    • 제16권5호
    • /
    • pp.108-114
    • /
    • 2012
  • 연료차단밸브의 운용조건하에서 열 및 유체 특성을 수치적으로 연구하였다. 밸브의 크기는 15 mm이 고 최대유량은 600 kph이다. 해석은 STAR-CCM+를 이용하여 수행하였다. 수치해석으로부터 얻은 결과는 시험치와 비교를 하였으며 전체적으로 peak에 도달하는 온도의 기울기는 유사한 경향을 보이며 온도값도 거의 일치를 하였다.

연료차단밸브의 열해석에 관한 수치적 연구 (A Numerical Study on Thermal Analysis of Fuel Shut-off Valve)

  • 백낙곤;이재윤
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.559-564
    • /
    • 2011
  • 연료차단밸브의 운용조건하에서 열 및 유체 특성을 수치적으로 연구하였다. 밸브의 크기는 15mm이고 최대유량은 600kph이다. 해석은 STAR-CCM+를 이용하여 수행하였다. 수치해석으로부터 얻은 결과는 시험치와 비교를 하였으며 전체적으로 peak에 도달하는 온도의 기울기는 유사한 경향을 보이며 온도값도 거의 일치를 하였다.

  • PDF

A Study on the Prevention of Spill of Fuel Oils and Lubricating Oils for Sunken Ships

  • Han, Won-Heui;Ju, Hae-Ji
    • 해양환경안전학회지
    • /
    • 제21권3호
    • /
    • pp.309-314
    • /
    • 2015
  • A sunken ship often involves an oil spill. This paper was carried out to minimize environmental and cost damages stemming from oil spil of sunken shipl. Through the analysis of both the standards of the oil tank system and installation, we have identified potential oil spill sites and proposed a remedy of prevention. The result of study, the air pipes of the oil tank are a vulnerable point for oil spill. Also, the remote control devices of emergency shut-off valve have poor accessibility at abandon ship, making it difficult to shut off the emergency shut-off valve. Thus, we propose the addition of a remote quick closing valve in the air pipe and the building of a central control system.

가스발생기 산화제 개폐밸브용 벨로우즈 구조 평가 (Structural Evaluations of Bellows for a Gasgenerator Lox Shut-off Valve)

  • 유재한;이중엽;이수용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.279-282
    • /
    • 2011
  • 가스 발생기 산화제 개폐 밸브에 사용되는 벨로우즈의 구조 해석 및 시험이 수행되었다. 해석은 상온 및 극저온에서 EJMA (Expansion Joint Manufacturing Association) 표준 및 상용 유한 요소 해석프로그램인 Abaqus v6.9를 이용하여 수행되었다. 스프링 강성, 응력 및 피로 수명 해석 결과들이 비교되었고 유한 요소 해석 결과에서 접촉 및 재질의 소성에 의한 영향을 살펴보았다.

  • PDF

연소기 산화제 개폐밸브 개방 특성 (Opening Characteristics of a Main Oxidizer Shut-off Valve)

  • 홍문근
    • 한국항공우주학회지
    • /
    • 제45권11호
    • /
    • pp.989-997
    • /
    • 2017
  • 액체로켓엔진용 연소기 산화제 개폐밸브로 사용되는 밸브 개방 자체유지가능형 포핏밸브의 밸브 개방 특성을 파악하기 위해 밸브 개방 과정에서의 과도 응답 특성에 대한 연구를 수행하였다. 수치해석을 위해 구동가스 공급시스템을 하나의 오리피스로 모델링하고 밸브 행정 위치 및 구동압력 조건에 따라 밸브 무빙파트의 운동방정식을 유도하였다. 상온 및 연소시험에서의 밸브 작동 시험결과와 계산 결과의 비교를 통해 계산 결과의 신뢰성을 검증하였으며, 본 연구의 실제적인 적용 예로써 높은 구동압력에서의 밸브 개방 속도 조절을 위한 오리피스 적용 사례를 소개하였다.