• Title/Summary/Keyword: Shunt resistance

Search Result 112, Processing Time 0.033 seconds

The Analysis of Electrical Characteristics of PV Module according to Mechanical Load Test (태양전지모듈의 기계적 하중시험에 따른 전기적 특성 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.247-251
    • /
    • 2008
  • In this paper. we analyze electrical characteristics of photovoltaic module according to mechanical load test. Using the equipment for giving load on the surface of module, dark current-voltage is measured. By varying load from 0kg to 206kg, slight different I-V curve is detected. From this, reduced shunt resistance is roughly calculated and micro crack is assumed to be happened. system Through this experiment, periodic external force on PV module might give an negative effect. The detailed analysis is described in the following paper.

  • PDF

A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems (765kV 비연가 송전계통 과도 특성에 관한 고찰)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

A Novel 800mV Beta-Multiplier Reference Current Source Circuit for Low-Power Low-Voltage Mixed-Mode Systems (저전압 저전력 혼성신호 시스템 설계를 위한 800mV 기준전류원 회로의 설계)

  • Kwon, Oh-Jun;Woo, Son-Bo;Kim, Kyeong-Rok;Kwack, Kae-Dal
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.585-586
    • /
    • 2008
  • In this paper, a novel beta-multiplier reference current source circuit for the 800mV power-supply voltage is presented. In order to cope with the narrow input common-mode range of the OpAmp in the reference circuit, shunt resistive voltage divider branches were deployed. High gain OpAmp was designed to compensate intrinsic low output resistance of the MOS transistors. The proposed reference circuit was designed in a standard 0.18um CMOS process with nominal Vth of 420mV and -450mV for nMOS and pMOS transistor respectively. The total power consumption including OpAmp is less than 50uW.

  • PDF

Generated heat decrease of thin film superconducting fault current limiter using diodes (Diode를 이용한 박막형 한류기의 열발생 저감방안)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.11-14
    • /
    • 2000
  • We fabricated a resistive superconducting fault current limiter (SFCL) of meander type based on a YBCO film. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. When diodes were inserted in the parallel circuit to restrict the temperature increase in the SFCL element by reducing power supply cycles, the voltage could be increased to $\sqrt{2}$ times with the same quench resistance at a half and full cycles.

  • PDF

Investigation on the Loop Current in the CICC Superconducting Magnet (관내연선도체 초전도 자석에서 루프 전류의 형성에 관한 연구)

  • 김석호;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.1
    • /
    • pp.33-37
    • /
    • 1999
  • The fast current and field ramp-up experiment was done with the superconducting magnet that is made of three non-insulated strand CICC (Cable-In- Conduit Conductor). The shunt the unbalanced current magnet enabled the unbalanced current measurement which is believed to be associated with the loop current. To explain the generation of the loop current during the current ramp up. the steady-state three strand loop current model was proposed. This model gives an explanation for the relation between the loop current and the twist geometry of the strands. According to this model. The twisr geometry and the surface contact resistance of the strand has significant influence on the generation of the loop current especially in the large superconducting magnet.

  • PDF

Operation properties of high $T_c$ superconductive current limiting fuse (고온 초전도 한류퓨즈의 동작특성)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Park, Kwon-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.67-68
    • /
    • 2001
  • We present the basic properties of a superconductive current limiting fuse (SCLF) based on YBCO/Au films. The SCLF consists of meander type YBCO stripes covered with an Au layer for current shunt. The fault current was first limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enables the SCLF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption.

  • PDF

The effect of Radiation Therapy on the Use of Proven Prosthesis in Laryngectomees (방사선 치료 환자에서의 Provox 사용)

  • 김광현;성명훈;이창호;전상준;고태용
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.2
    • /
    • pp.177-181
    • /
    • 1998
  • Provox is now widely used for voice rehabilitation for total laryngectomized patient because of its low airway resistance and easiness for phonation. This study was designed to reveal the influence of radiation therapy on Proven complications. Forty-four patients who underwent total laryngectomy were grouped into group A (no radiation), group B(radiation and then Provox insertion), group C(Proven insertion and then radiation). Provox complications were leakage, granulation tissue formation, malfunction and infection. The average survival time of Provox was longer in group C (9.2 me) than group A(8.6 m) or group B (7.3 me), but no statistical significance was found. The first time of Provox change was 10.2, 8.6 and 9.7 months respectively. The incidence of complication was not significantly different among groups. The cases of Provox remeval due to shunt failure were 5, 4 and 2 respectively. Even though a significant statistically difference was not found partialy due to the small numbers of patients, a special caution should be exercised in inserting Provox to prevent a serious complication for the patients who had a history of previous radiation.

  • PDF

Commutation Characteristic Analysis of DC Motor for Circuit Parameters (회로정수를 이용한 직류전동기의 정류 특성 해석)

  • Kim, Young-Sun;Lee, Joon-Ho;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.641-643
    • /
    • 2000
  • Because of high torque and easiness of speed control, Direct Current(DC) motors are used long time. But, its applications are limited in circumstance and performance, since they contained brush and commutator. The commutation characteristic gives effect to life and performance of DC motor. Naturally, the commutation characteristic analysis is strongly required. In this paper, With the result of finite element analysis. The inductance is calculated each rotor position and applied to the voltage equations coupled with commutation equation. The time derivative term in the differential equation is solved in time difference method. This algorithm was applied to 2-pole shunt DC motor. We considered commutation characteristic by changing contact resistance between brush and commutator segment.

  • PDF

Generated heat decrease of resistive superconducting fault current limiter using diodes (Diode를 이용한 저항형 초전도 한류기의 열발생 저감방안)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.925-927
    • /
    • 2000
  • We fabricated a resistive superconducting fault current limiter of meander type based on a YBCO film. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. When diodes were inserted in the parallel circuit to restrict the temperature increase in the SFCL element by reducing power supply cycles, the voltage could be increased to $\sqrt{2}$ times with the same quench resistance at a half and full cycles.

  • PDF

The Characteristics of a Hydrogenated Amorphous Silicon Semitransparent Solar Cell When Applying n/i Buffer Layers

  • Lee, Da Jung;Yun, Sun Jin;Lee, Seong Hyun;Lim, Jung Wook
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.730-733
    • /
    • 2013
  • In this work, buffer layers with various conditions are inserted at an n/i interface in hydrogenated amorphous silicon semitransparent solar cells. It is observed that the performance of a solar cell strongly depends on the arrangement and thickness of the buffer layer. When arranging buffer layers with various bandgaps in ascending order from the intrinsic layer to the n layer, a relatively high open circuit voltage and short circuit current are observed. In addition, the fill factors are improved, owing to an enhanced shunt resistance under every instance of the introduced n/i buffer layers. Among the various conditions during the arrangement of the buffer layers, a reverse V shape of the energy bandgap is found to be the most effective for high efficiency, which also exhibits intermediate transmittance among all samples. This is an inspiring result, enabling an independent control of the conversion efficiency and transmittance.