• Title/Summary/Keyword: Shunt resistance

Search Result 112, Processing Time 0.044 seconds

Preparation and Properties of ZnSe/Zn3P2 Heterojunction Formed by Surface Selenization of Zn3P2 Film Deposited on ZnTe Layer

  • Park, Kyu Charn;Cha, Eun Seok;Shin, Dong Hyeop;Ahn, Byung Tae;Kwon, HyukSang
    • Current Photovoltaic Research
    • /
    • v.2 no.1
    • /
    • pp.8-13
    • /
    • 2014
  • ZnSe/$Zn_3P_2$ heterojunctions with a substrate configuration were fabricated using a series of cost-effective processes. Thin films of ZnTe and $Zn_3P_2$ were successively grown by close-spaced sublimation onto Mo-coated glass substrates. ZnSe layers thinner than 100nm were formed by annealing the $Zn_3P_2$ films in selenium vapor. Surface selenization generated a high density of micro-cracks which, along with voids, provided shunt paths and severely deteriorated the diode characteristics. Annealing the $Zn_3P_2$ film at $300^{\circ}C$ in a $ZnCl_2$ atmosphere before surface selenization produced a dense microstructure and prevented micro-crack generation. The mechanism of micro-crack generation by the selenization was described and the suppression effect of $ZnCl_2$ treatment on the micro-crack generation was explained. ZnSe/$Zn_3P_2$ heterojunctions with low leakage current ($J_0$ < $1{\mu}A/cm^2$) were obtained using an optimized surface selenization process with $ZnCl_2$ treatment. However, the series resistance was very high due to the presence of an electrical barrier between the ZnTe and $Zn_3P_2$ layers.

CMOS Rectifier for Wireless Power Transmission Using Multiplier Configuration (Multiplier 설정을 통한 무선 전력 전송 용 CMOS 정류 회로)

  • Jeong, Nam Hwi;Bae, Yoon Jae;Cho, Choon Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.56-62
    • /
    • 2013
  • We present a rectifier for wireless power transmission using multiplier configuration in layout for MOSFETs which works at 13.56 MHz, designed to fit in CMOS process where conventionally used diodes are replaced with the cross-coupled MOSFETs. Full bridge rectifier structure without comparators is employed to reduce current consumption and to be working up to higher frequency. Multiplier configuration designed in layout reduces time delay originated from parasitic series resistance and shunt capacitance at each finger due to long connecting layout, leading to fast transition from on-state to off-state cross-coupled circuit structure and vice versa. The power conversion efficiency is significantly increased due to this fast transition time. The rectifier is fabricated in $0.11{\mu}m$ CMOS process, RF to DC power conversion efficiency is measured as 86.4% at the peak, and this good efficiency is maintained up to 600 MHz, which is, to our best knowledge, the highest frequency based on cross-coupled configuration.

Fabrication and Fault Test Results of Bi-2212/Cu-Ni Tubes for Superconducting Fault Current Limiting Elements (Bi-2212/Cu-Ni 튜브로 제작한 초전도 한류소자의 단락사고시험 결과)

  • Oh, S.Y.;Yim, S.W.;Yu, S.D.;Kim, H.R.;Hyun, O.B.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.45-49
    • /
    • 2008
  • For the development of superconducting fault current limiters (SFCLs), fault current limiting elements were fabricated out of Bi-2212 bulk tubes and tested. The SFCL elements consisted of tube shaped Bi-2212 bulks and metal shunts for the stabilizers. Firstly, the Bi-2212 bulk tubes were processed based on a design of monofilar coils in order to acquire large resistance and high voltage rating. 300 mm-long Bi-2212 tubes were designed to have the current path of 410 cm in length with 24 turns and 41 mm in diameter. The processed monofilar coil, as designed, had 300 A $I_c$ at 77 K. The fabricated superconducting monofilar coils were affixed to Cu-Ni alloy as that of stabilizers. The Cu-Ni alloys were processed to have the same shape of the superconducting monofilar coils. The Cu-Ni coil had resistivity of 32 ${\mu}{\Omega}$-cm at 77 K and 37 ${\mu}{\Omega}$-cm at 300 K. The metal shunts were attached to the outside of the Bi-2212 monofilar coil by a soldering technique. After the terminals made of copper were attached to both ends of the superconductor-metal shunt composite, the gap between the turns and the surface of the elements was filled with an epoxy and a dense mesh made of FRP in order to enhance the mechanical strength. The completed SFCL elements went through fault tests, and we confirmed that the voltage rating of 143 $V_{rms}$ (E =0.35 $V_{rms}$/cm) could be accomplished.

  • PDF

Preliminary study on the quench protection of Bi-22231 Ag tape using superconducting fault current limiter (초전도 한류기를 이용한 Bi-2223/Ag 선재의 퀜치 보호를 위한 기초 연구)

  • Du, Ho-Ik;Yim, Seong-Woo;Hyun, Ok-Bae;Hwang, Si-Dole;Cho, Chul-Yong;Park, Chung-Ryul;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.243-244
    • /
    • 2006
  • As an preliminary study for the quench protection of high temperature superconducting (HTS) cable using superconducting fault current limiter (SFCL), experimental research was carried out. The test circuit was composed of Bi-2223/Ag HTS tape and a SFCL made of YBCO thin films. In the normal state, the applied current of 56 A, which was critical current of HTS tape, could be flown through the circuit without resistive loss. Increasing the currents, the quench development of both materials was investigated from the voltage signal acquired from the resistance of the quenched superconductor. Up to around 10 times of the critical current was applied to the HTS tape and the current limiting characteristics of SFCL were investigated. In addition, for the finding out the optimal operating condition of SFCL such as the numbers of elements, a shunt resistor was applied to the SFCL and quench characteristics were analyzed as well.

  • PDF

Preparation of a Dense Cu(In,Ga)Se2 Film From (In,Se)/(Cu,Ga) Stacked Precursor for CIGS Solar Cells

  • Mun, Seon Hong;Chalapathy, R.B.V.;Ahn, Jin Hyung;Park, Jung Woo;Kim, Ki Hwan;Yun, Jae Ho;Ahn, Byung Tae
    • Current Photovoltaic Research
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • The $Cu(In,Ga)Se_2$ (CIGS) thin film obtained by two-step process (metal deposition and Se annealing) has a rough surface morphology and many voids at the CIGS/Mo interface. To solve the problem a precursor that contains Se was employer by depositing a (In,Se)/(Cu,Ga) stacked layer. We devised a two-step annealing (vacuum pre-annealing and Se annealing) for the precursor because direct annealing of the precursor in Se environment resulted in the small grains with unwanted demarcation between stacked layers. After vacuum pre-annealing up to $500^{\circ}C$ the CIGS film consisted of CIGS phase and secondary phases including $In_4Se_3$, InSe, and $Cu_9(In,Ga)_4$. The secondary phases were completely converted to CIGS phase by a subsequent Se annealing. A void-free CIGS/Mo interface was obtained by the two-step annealing process. Especially, the CIGS film prepared by vacuum annealing $450^{\circ}C$ and subsequent Se annealing $550^{\circ}C$ showed a densely-packed grains with smooth surface, well-aligned bamboo grains on the top of the film, little voids in the film, and also little voids at the CIGS/Mo interface. The smooth surface enhanced the cell performance due to the increase of shunt resistance.

In Vivo Characterization of Phosphotransferase-Encoding Genes istP and forP as Interchangeable Launchers of the C3',4'-Dideoxygenation Biosynthetic Pathway of 1,4-Diaminocyclitol Antibiotics

  • Nguyen, Lan Huong;Lee, Na Joon;Hwang, Hyun Ha;Son, Hye Bin;Kim, Hye Ji;Seo, Eun Gyo;Nguyen, Huu Hoang;Park, Je Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.3
    • /
    • pp.367-372
    • /
    • 2019
  • Deactivation of aminoglycosides by their modifying enzymes, including a number of aminoglycoside O-phosphotransferases, is the most ubiquitous resistance mechanism in aminoglycoside-resistant pathogens. Nonetheless, in a couple of biosynthetic pathways for gentamicins, fortimicins, and istamycins, phosphorylation of aminoglycosides seems to be a unique and initial step for the creation of a natural defensive structural feature such as a 3',4'-dideoxy scaffold. Our aim was to elucidate the biochemical details on the beginning of these C3',4'-dideoxygenation biosynthetic steps for aminoglycosides. The biosynthesis of istamycins must surely involve these 3',4'-didehydroxylation steps, but much less has been reported in terms of characterization of istamycin biosynthetic genes, especially about the phosphotransferase-encoding gene. In the disruption and complementation experiments pointing to a putative gene, istP, in the genome of wild-type Streptomyces tenjimariensis, the function of the istP gene was proved here to be a phosphotransferase. Next, an in-frame deletion of a known phosphotransferase-encoding gene forP from the genome of wild-type Micromonospora olivasterospora resulted in the appearance of a hitherto unidentified fortimicin shunt product, namely 3-O-methyl-FOR-KK1, whereas complementation of forP restored the natural fortimicin metabolite profiles. The bilateral complementation of an istP gene (or forP) in the ${\Delta}forP$ mutant (or ${\Delta}istP$ mutant strain) successfully restored the biosynthesis of 3',4'-dideoxy fortimicins and istamycins, thus clearly indicating that they are interchangeable launchers of the biosynthesis of 3',4'-dideoxy types of 1,4-diaminocyclitol antibiotics.

Primary Surgical Closure of Large Ventricular Septal Defects in Small Infants (조기 영아기 심실 중격 결손의 개심술)

  • 최종범;양현웅
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.486-492
    • /
    • 1997
  • We r viewed a policy of primary surgical closure of large ventricular septal defects in small infants. Sixty-three infants met criteria for inclusion in the study, and were divided into two groups based on age: group 1 infants aged less than 5 months(n = 31), and group 2 infants aged 5 months or more(n = 32). Both groups had similar variation in ventricular septal defect location(paramembranous versus muscular), and showed no significant difference in left to right shunt and in ratio of systemic and pulmonary vascualr resistance. Three early deaths(9.7%) occurred in group 1, but no death(0%) in group 2. The causes of death were preoperative cardiac arrest and cerebral injury followed by postoperative respiratory insufficiency in two patients, and preoperative tracheomalacia followed by laryngeal edema and respiratory arrest in one Two patients in group 1 showed postoperative low cardiac output syndrome(6.5% in group 1 versus 0% in group 2). There was no late death during the follow-up per od in both groups. No surviving patients had postoperative patch leakage, or required a second operation. These results indicate that primary surgical closure of large ventricular septal defects, if logical perioperative care is accompanied, can be saefly performed in small infants aged less than 5 months with low postoperative mortality or morbidity rates.

  • PDF

Long-Term Experiences of the Provox Voice Prosthesis at Snuh (서울대학교병원에서의 Provox 장기간 사용경험)

  • Jung, Young-Ho;Park, Jun-Beom;Won, Tae-Bin;Lee, Seung-Shin;Mo, Ji-Hun;Park, Seok-Won;Sung, Myung-Whun;Kim, Kwang-Hyun
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.130-137
    • /
    • 1999
  • Background and Objectives : Provox, a recently developed tracheoesophageal prosthesis, had been widely used for voice rehabilitation after total laryngectomy for its low resistance and easiness of speech ability. But, long-term use of Provox resulted in many complications and resulted in cessation of Provox as a primary method of vocal rehabilitation. The aim of this study is to report Provox-related problems and the long-term results of Provox voice prosthesis. Materials and Methods : Medical records from patients who had undergone total laryngectomy with Provox insertion at seoul National University Hospital between January 1993 and December 1998 were reviewed retrospectively. Results : 36 patients had used 79 Provox voice prostheses during the observed period. The most common complication causing prosthesis change or removal was leakage and/or aspiration, followed by granulation formation, crusting and/or obstruction, and non-function. Median in situ lifetime of Provox was 274 days and 1-year-in situ rate was 31.0% Among 36 patients, 17 patients had undergone tracheoesophageal shunt closure at the last follow-up visit. 10 patients had complications but got along without further treatments, and 1 patient changed to Blom-Singer voice prosthesis. Only 8 patients experienced no complication, and 5 out of whom had several times of Provox change. Conclusion : long-term use of Provox resulted in discontinuation of its use due to complications in many cases. A better voice prosthesis with lower complication rate and longer in situ lifetime is needed.

  • PDF

Effect of Inhaled Nitric Oxide on Hemodynamics, Gas Exchange and Pulmonary Inflammation in Newborn Piglets with Escherichia coli Induced Septic Lungs (패혈성 폐가 유도된 신생자돈에서 외인성 Nitric Oxide 흡입의 혈역학, 가스교환 및 폐 염증에 대한 효과)

  • Chang, Yun Sil;Ko, Sun Young;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.8
    • /
    • pp.777-783
    • /
    • 2003
  • Purpose : The aim of this study was to evaluate the effect of inhaled nitric oxide(iNO) on gas exchange, hemodynamics and pulmonary inflammation in newborn piglets with E. coli induced septic lung. Methods : Twenty three instrumented and ventilated piglets were randomized into three groups : CON(n=6), PCON(n=9), and PNO(n=8). In the piglets of the PCON and PNO groups, E. coli septic lung was induced by endotracheal instillation of E. coli. Ten ppm iNO was given continuously in the PNO group after endotracheal instillation of E. coli. All animals were mechanically ventilated for six hour with a peak inspiratory pressure of 30 $cmH_2O$, frequency of 25 breaths/min, $FiO_2$ 1.0 and a positive end-expiratory pressure of 4 $cmH_2O$. All measurements were made at one hour intervals during the experiment. At the end of the experiment, lung tissue was harvested for the analysis of myeloperoxidase activity, indicative of lung inflammation. Results : All piglets with pulmonary instillation of E. coli developed E. coli sepsis. Piglets in the PCON group developed progresseve pulmonry hypertension, hypoxemia and hypercarbia compared to the CON group due to increased pulmonary vascular resistance, intrapulmonary shunt fraction and physiologic dead space fraction. iNO did not reverse pulmonary hypertension in the PNO group. However iNO significantly improved oxygenation, which was attributed to marked improvement of venous admixture and partial attenuation of increase in dead space fraction. Increased myeloperoxidase activity in PCON compared to CON was significantly attenuated in PNO. Conclusion : iNO improves oxygenation and lung inflammation in newborn piglets with E. coli induced septic lung.

A Study on the Neumann-Kelvin Problem of the Wave Resistance (조파저항에서의 Neumann-Kelvin 문제에 대한 연구)

  • 김인철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.2
    • /
    • pp.131-136
    • /
    • 1985
  • The calculation of the resulting fluid motion is an important problem of ship hydrodynamics. For a partially immersed body the condition of constant pressure at the free surface can be linearized. The resulting linear boundary-value problem for the velocity potential is the Neumann-Kelvin problem. The two-dimensional Neumann-Kelvin problem is studied for the half-immersed circular cylinder by Ursell. Maruo introduced a slender body approach to simplify the Neumann-Kelvin problem in such a way that the integral equation which determines the singularity distribution over the hull surface can be solved by a marching procedure of step by step integration starting at bow. In the present pater for the two-dimensional Neumann-Kelvin problem, it has been suggested that any solution of the problem must have singularities in the corners between the body surface and free surface. There can be infinitely many solutions depending on the singularities in the coroners.

  • PDF