• Title/Summary/Keyword: Short-Range

Search Result 2,247, Processing Time 0.032 seconds

Unambiguous Fiber Fabry-Perot Temperature Sensor by an Additional Partial Mirror (보조 반사체를 이용한 광섬유 페브리페로 간섭계형 온도센서의 성능향상)

  • Kim, Gwang-Su;Lee, Hong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.418-423
    • /
    • 2000
  • The fiber Fabry-Perot interferometric(FFPI) sensor is well known in the field of industrial diagnosis due to its outstanding properties such as tiny size, simple and rugged structure, and easy interrogation. As other fiber interferometric sensors, it also suffers from ambiguous output caused by highly periodic feature in its optical transfer function. In most cases, the ambiguity leads to relatively short dynamic operating range and long processing time during power-on reset, which limits its application to some specific fields requiring very high resolution. In this paper a method based on double sensing scheme was proposed to overcome the above difficulty. By employing a fringe selection auxiliary FFPI sensor the original FFPI sensor can identify its true position on the phase domain. The performance test with 10mm FFPI sensor and a thermocouple temperature sensor for reference shows wide dynamic range 0-900$\ell$ keeping a reasonable resolution of 0.1$\ell$ over the entire range.

  • PDF

A Case Study on Analysis Methodology of Costal Defence Weapon System (해안방어 무기체계 효과분석 방법론: 사례연구를 중심으로)

  • Shin, Sang-Wook;Choi, Bong-Wan;Oh, Cheon-Kyun;Jo, Han-Moo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.124-134
    • /
    • 2019
  • As the types of North Korea's provocation are diverse and unexpectable in the costal area, ROK navy needs to develop countermeasures, such as costal defence guided rockets. Recently ROK navy developed the PKX-B which is equipped with the new 130 mm guided rocket. The most popular rockets are LOGIR for short range targets, 130 mm guided rocket for middle range targets and Spike-NLOS for long range targets. As various guided rockets are developed, it is required to develop a guided rocket analysis model and it's analysis methodology. In addition, these guided rockets can be installed on any platforms; ground vehicle, aircraft and warship. The paper proposes systematic methodology to estimate the operational effectiveness of costal defence guided rockets. A case study exploiting the ARENA simulation model is explained to demonstrate the implementation of the proposed methodology.

Design of Circularly Polarization Patch Array Antenna for DSRC (DSRC 통신을 위한 원형 편파 패치 배열 안테나 설계)

  • Kim, Hyun-Chul;Jung, Jin-Woo;Lee, Hyeon-Jin;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.144-150
    • /
    • 2012
  • In this paper, circularly polarization patch array antenna of RSE(Road-side Equipment) base station for DSRC(Dedicated Short Range Communication) of ITS(Intelligent Transport System) is proposed. The antenna of RSE base station for DSRC is designed to operate circularly polarization to receive reflected signal from multiplex path effectively. The proposed antenna consisted of microstrip patch and feed line, the slit is inserted in the proximity of the slot of feed structure to generate circularly polarization. The $2{\times}2$ array structure is designed to satisfying gain that DSRC RSE base station antenna required. Measured impedance bandwidth and axial-ratio bandwidth are satisfied by all DSRC band of 5.795~5.855 GHz. Vertical and horizontal HPBW of the proposed antenna are both about 43 degrees, it showed gain characteristic of about 11.21 dBi.

A Study on the Implementation of Wideband Hybrid Quadrature Polar Transmitter Platform (광대역 하이브리드 직교 폴라 송신 플랫폼 구현에 관한 연구)

  • Chang, Sang-Hyun;Lee, Il-Kyoo;Kim, Hyung-Jung;Kang, Sang-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1A
    • /
    • pp.28-34
    • /
    • 2011
  • In this paper, we proposed the architecture of the Hybrid Quadrature Polar transmitter which has the wideband characteristics available for the SRD(Short Range Device). First, we developed the simulation environment and carried out performance degradation analysis. Second, we considered the slewrate of the VVA(Voltage Variable Attenuator), time delay between magnitude signal and phase signal and the number of bits for DAC(Digital-to-Analog Converter) as the main performance factors. Then we obtained the minimum required values to meet the transmitting performance requirements of 3GPP standards through simulation results. Based on these results, we implemented the Wideband Hybrid Quadrature Polar transmitter platform and varified the performance requirements through practical measurement.

Time-domain Geoacoustic Inversion of Short-range Acoustic Data with Fluctuating Arrivals (시변동이 있는 근거리 음향신호의 시간영역 지음향학적 역산)

  • Park, Cheolsoo;Seong, Woojae;Gerstoft, Peter;Hodgkiss, William S.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.308-316
    • /
    • 2013
  • A set of experiments (Shallow Water 2006, SW06) was carried out in shallow water near the New Jersey shelf break in summer 2006. Significant fluctuations in direct and surface reflected arrivals were observed from the chirp data (1100~2900 Hz) measured on a vertical line array. This paper presents a geoacoustic inverssion technique for short-range acoustic data with fluctuating arrivals and inversion results of experimental data. In order to reduce effects of random sea surface on the inversion, the acoustic energy back-propagated from the array to the source through direct and bottom-reflected paths is defined as the objective function. A multi-step inversion scheme is applied to the data using VFSR (Very Fast Simulated Reannealing) optimization technique. The inversion results show a source depth oscillation period equal to the measured ocean surface wave period. The inverted bottom sound speed is 1645 m/s and is similar to that estimated by other work at the same site.

Extraction of Effective Carrier Velocity and Observation of Velocity Overshoot in Sub-40 nm MOSFETs

  • Kim, Jun-Soo;Lee, Jae-Hong;Yun, Yeo-Nam;Park, Byung-Gook;Lee, Jong-Duk;Shin, Hyung-Cheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.115-120
    • /
    • 2008
  • Carrier velocity in the MOSFET channel is the main driving force for improved transistor performance with scaling. We report measurements of the drift velocity of electrons and holes in silicon inversion layers. A technique for extracting effective carrier velocity which is a more accurate extraction method based on the actual inversion charge measurement is used. This method gives more accurate result over the whole range of $V_{ds}$, because it does not assume a linear approximation to obtain the inversion charge and it does not limit the range of applicable $V_{ds}$. For a very short channel length device, the electron velocity overshoot is observed at room temperature in 37 nm MOSFETs while no hole velocity overshoot is observed down to 36 nm. The electron velocity of short channel device was found to be strongly dependent on the longitudinal field.

Ka-band Power Amplifiers for Short-range Wireless Communication in $0.18-{\mu}m$ CMOS Process ($0.18-{\mu}m$ CMOS공정을 이용한 Ka 대역 근거리 무선통신용 전력증폭기 설계)

  • He, Sang-Moo;Lee, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.4
    • /
    • pp.131-136
    • /
    • 2008
  • Two Ka-band 3-stage power amplifiers were designed and fabricated using $0.18-{\mu}m$ CMOS technology. For low loss matching networks for the amplifiers, two substrate-shielded transmission line structures, having good modeling accuracy up to 40 GHz were used. The measured insertion loss of substrate-shielded microstrip-line (MSL) was 0.5 dB/mm at 27 GHz. A 3-stage CMOS amplifier using substrate-shielded MSL achieved a 14.7-dB small-signal gain and a 14.5-dBm output power at 27 GHz in a compact chip area of 0.83$mm^2$. The measured insertion loss of substrate-shielded coplanar waveguide (CPW) was 1.0 dB/mm at 27 GHz. A 3-stage amplifier using substrate-shielded CPW achieved a 12-dB small-signal gai and a 12.5-dBm output power at 26.5 GHz. This results shows a potential of CMOS technology for low cost short-range wireless communication components and system.

A Study on the Indication for Thoracotomy and Operation Results of Spontaneous Pneumothorax (자연기흉의 개흉술 적응과 수술성적에 관한 연구)

  • Lee, Jae-Won;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.39-47
    • /
    • 1987
  • The records of 268 patients, who were diagnosed as spontaneous pneumothorax during the period 1975 to 1984, treated at the department of thoracic and cardiovascular surgery, Hanyang University Hospital, were reviewed retrospectively to evaluate the effect of surgical intervention on each indications. Of these,.61 patients [22.8%] were taken operation to treat the pneumothorax after closed thoracostomy. We have classified the 61 patients to evaluate the therapeutic effect on each indications. And the therapeutic effect is based on the chest tube indwelling days. The results were as follows: 1. The chest tube indwelling days of the group who were taken closed thoracostomy only was average 14.13*9.17 days [range 5-66 days], and that of the group who were finally taken the thoracotomy after closed thoracostomy was 21.85*12.30 days [range 5-55 days]. 2. The indications of thoractomy were thoracoscopic findings, recurrence and continuous air leakage. 3. The chest tube indwelling day of the group who was taken thoracotomy by thoracoscopic findings was average 11.67*6.51 day, that was relatively short compared to those of the other groups. 4. The continuous air leakage group after closed thoracostomy was subdivided into three subgroups, continuous air leakage in 1st attack, thoracoscopic findings in 1st attack, and recurrence. 5. Of these, the chest tube indwelling day of the subgroup, who was taken operation by thoracoscopic findings, was 21.33e8.26, that was relatively short compared with those of the other subgroups. We use the thoracoscope as excellent diagnostic tool to detect the operation indication in the spontaneous pneumothorax patients. And we gain the benefits to shorten the chest tube indwelling days and admission days, and also to protect the recurrence.

  • PDF

Short-range Monitoring of Marine AtoN Charge and Discharge Controller (해상용 항로표지 충·방전조절기의 근거리 모니터링)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.933-939
    • /
    • 2015
  • If the Visual Aids(light wave signs) is not supplied the general power it is using solar power system. These power supply systems, the role of the charge/discharge control is very important. Introduction of IT(AIS etc.) for the effective management of the AtoN(Aids to Navigation) is a Visual Aids has been added to the device using the power to charge/discharge control, the need increases. The current charge/discharge controller is attached to the inside of the AtoN and checks on and verification of the maritime environment, depending on the difficulty. In order to resolve these issues in this paper, the Bluetooth module is mounted on the inside of the charge/discharge controller and proposed a possible system monitoring at close range. Advantage of the system implemented is a simple configuration and low installation cost. In addition, it can be applied to a variety of AtoN. Also, it has been able to check the real-time status information of the charge/discharge controller at a short distance in to reduce inspection costs, and reduce risk factors that might occur during check.

Validity and Reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in Knee Osteoarthritis Patients (골관절염영향측정척도(AIMS-SF)의 타당도 및 신뢰도 - 일부 슬관절 골관절염 환자를 대상으로 -)

  • Yi, Seung-Ju;Nam, Tae-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.5
    • /
    • pp.29-41
    • /
    • 2007
  • Purpose: The aim of this study was to examine the validity and reliability on Psychometric Arthritis Impact Measurement Scale-Short Form (AIMS-SF) in patients with knee osteoarthritis(OA). Methods: The sample consisted of 62 patients who had received physical therapy at the physical therapy units of the Andong Medical Center, Sungso Hospital, Ahn Orthopedic Surgery Clinic, and St. Luke Clinic in Andong city in June 2006. Questionnaire on the AIMS-SF was recruited by 5 physical therapists. The internal structure and reliability of the scales were evaluated by means of item-internal consistency(Cronbach's alpha coefficient: ${\alpha}$), item-discriminant validity, Pearson's relation coefficient. To explore construct validity we conducted a principal component factor analysis with varimax rotation analysis. The criterion for factor extraction was an eigenvalue >1.0. Results: 62 OA patients's an average $age{\pm}standard$ deviation was $53.8{\pm}14.4$ years (range: $40{\sim}81$ yr). The internal consistency reliability of 11 items, as estimated by Cronbach's ${\alpha}$ coefficient, was high ranging $0.60{\sim}0.78$ (except for 0.40 for mobility level and -0.48 for mood). The internal consistency reliability of item-each scale was also high $0.82{\sim}0.93$ (except for 0.48 for mood). Of 11 items, the item-discriminant validity on 6 items was high (${\alpha}$ coefficient range: $0.11{\sim}0.25$), however, others (0.57 for tension level, 0.48 for arthritis pain, 0.41 for walking and bending, and 0.40 for work) were a little low. The construct validity by factor analysis was a little low. Conclusion: In conclusion, the results reported here confirm the validity and reliability of the AIMS-SF in patients with OA of the knee. The Collection of information on health status using this instrument was acceptable to patients. A further prospective multi-center study will be necessary to prove the construct validity.

  • PDF