• 제목/요약/키워드: Short circuit control

검색결과 264건 처리시간 0.031초

3상 유도전동기 구동을 위한 새로운 제어방식의 인버어터에 관한 연구 (A Study on the New Controlled Method of the Inverter for Three Phase Induction Motor Drive)

  • 서윤철;김영민;박현철;이성룡;유철로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.336-338
    • /
    • 1996
  • Inverter is classified into voltage source and current source by the circuit's configuration. VSI (voltage source inverter) has the excellent generality, economical effects and high power-factors. CSI (current source inverter) is proper to frequent acceleration and deceleration of induction motor, the energy recovering accomplished to ac power line without any other device. But CSI inverter have some troubles such that the numbers of components are increased and the circuits are complicated. To solve these problems, a new inverter is proposed in this paper. This method gives protection of inverters when appears both an instantaneous load-open circuits and an instantaneous load-short circuits, and it has the both merits of both VSI and CSI.

  • PDF

High Efficiency Active Clamp Forward Converter with Synchronous Switch Controlled ZVS Operation

  • Lee Sung-Sae;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제6권2호
    • /
    • pp.131-138
    • /
    • 2006
  • An active clamp ZVS PWM forward converter using a secondary synchronous switch control is proposed in this paper. The proposed converter is suitable for low-voltage and high-current applications. The structure of the proposed converter is the same as a conventional active clamp forward converter. However, since it controls the secondary synchronous switch to build up the primary current during a very short period of time, the ZVS operation is easily achieved without any additional conduction losses of magnetizing current in the transformer and clamp circuit. Furthermore, there are no additional circuits required for the ZVS operation of power switches. Therefore, the proposed converter can achieve high efficiency with low EMI noise, resulting from soft switching without any additional conduction losses, and shows high power dens~ty, a result of high efficiency, and requires no additional components. The operational principle and design example are presented. Experimental results demonstrate that the proposed converter can achieve an excellent ZVS performance throughout all load conditions and demonstrates significant improvement in efficiency for the 100W (5V, 20A) prototype converter.

단상 PV 인버터용 온라인 데드타임 보상기 연구 (A New On-Line Dead-Time Compensator for Single-Phase PV Inverter)

  • 부우충기엔;이상회;차한주
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.409-415
    • /
    • 2012
  • This paper presents a new software-based on-line dead-time compensation technique for a single-phase grid-connected photovoltaic (PV) inverter system. To prevent a short circuit in the inverter arms, a switching delay time must be inserted in the pulse width modulation (PWM) signals. This causes the dead-time effect, which degrades the system performance around zero-crossing point of the output current. To reduce the dead-time effect around the zero-crossing point of grid current, a harmonic mitigation of grid current is used as an additional part of the synchronous frame current control scheme. This additional task mitigates the harmonic components caused by the dead-time from the grid current. Simulation and experimental results are shown to verify the effectiveness of the proposed dead-time compensation method in the single-phase grid-connected inverter system.

Proteotoxic Stress and Cell Lifespan Control

  • Cenci, Simone;Pengo, Niccolo;Sitia, Roberto
    • Molecules and Cells
    • /
    • 제26권4호
    • /
    • pp.323-328
    • /
    • 2008
  • Eukaryotic cells continuously integrate intrinsic and extrinsic signals to adapt to the environment. When exposed to stressful conditions, cells activate compartment-specific adaptive responses. If these are insufficient, apoptosis ensues as an organismal defense line. The mechanisms that sense stress and set the transition from adaptive to maladaptive responses, activating apoptotic programs, are the subject of intense studies, also for their potential impact in cancer and degenerative disorders. In the former case, one would aim at lowering the threshold, in the latter instead to increase it. Protein synthesis, consuming energy for anabolic processes as well as for byproducts disposal, can be a significant source of stress, particularly when difficult-to-fold proteins are produced. Recent work from our and other laboratories on the differentiation of antibody secreting cells, revealed a regulatory circuit that integrates protein synthesis, secretion and degradation (proteostasis), into cell lifespan determination. The apoptotic elimination - after an industrious, yet short lifetime - of terminal immune effectors is crucial to maintain immune homeostasis. Linking proteostasis to cell death, this paradigm might prove useful for biotechnological purposes, and the design of novel anti-cancer therapies.

금속 필러가 첨가된 Pb-B-O계 유리와 Ni-Cr 합금 와이어 간의 전기 화학적 반응과 단락 거동 (Electrochemical Reaction and Short-Circuit Behavior between Lead Borate Glass Doped with Metal Filler and Ni-Cr Alloy Wire)

  • 최진삼;다타치카 나까야마
    • 한국재료학회지
    • /
    • 제31권8호
    • /
    • pp.471-479
    • /
    • 2021
  • The electrochemical reaction between lead borate glass frit doped with Sn metal filler and Ni-Cr wire of a J-type resistor during a term of Joule heating is investigated. The fusing behavior in which the Ni-Cr wire is melted is not observed for the control group but measured for the Sn-doped specimen under 30 V and 500 mA. The Sn-doped lead borate glass frit shows a fusing property compared with other metal-doped specimens. Meanwhile, the redox reaction significantly contributes to the fusing behavior due to the release of free electrons of the metal toward the glass. The electrons derived from the glass, which used Joule heat to reach the melting point of Ni-Cr wire, increase with increasing corrosion rate at interface of metal/glass. Finally, the confidence interval is 95 ± 1.959 %, and the adjusted regression coefficient, R in the optimal linear graph, is 0.93, reflecting 93% of the data and providing great potential for fusible resistor applications.

Recent Advances in a-IGZO Thin Film Transistor Devices: A Short Review

  • Jingwen Chen;Fucheng Wang;Yifan Hu;Jaewoong Cho;Yeojin Jeong;Duy Phong Pham;Junsin Yi
    • 한국전기전자재료학회논문지
    • /
    • 제36권5호
    • /
    • pp.463-473
    • /
    • 2023
  • In recent years, the transparent amorphous oxide thin film transistor represented by indium-gallium-zinc-oxide (IGZO) has become the first choice of the next generation of integrated circuit control components. This article contributes an overview of IGZO thin-film transistors (TFTs), including their fundamental principles and recent advancements. The paper outlines various TFT structures and places emphasis on the fabrication process of the active layer. The result showed that the size of the active layer including the length-to-width ratio and the width could have a significant effect on the mobility. And the process of TFT could influence the crystal structure of IGZO thin film. Furthermore, the article presents an overview of recent applications of IGZO TFTs, such as their use in display drivers and TFT memories. At last, the future development of IGZO TFT is forecasted in this paper.

LightGBM을 이용한 수력 펌프 유량 추정의 실험적 연구 (An Experimental Study on the Estimation Flow-rate of Venturi Pump Using LightGBM)

  • 정진범;이지환;강명철
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권4호
    • /
    • pp.123-132
    • /
    • 2023
  • In disaster situations, to facilitate rapid drainage, electric underwater pumps are installed manually. This poses a high risk of electric shock accidents due to a short circuit, and a lot of time is required for hose connection and installation of electrical devices. To solve these problems, a Venturi pump using the venturi effect without external power is used. However, Venturi pumps that operate without external power make it difficult to install flow sensors such as electric devices; consequently, it is difficult to check the real-time flow rate. This paper proposes a flow estimation logic to replace the function of the flow sensor for the venturi pump . To develop the flow estimation logic, the flow characteristics of the venturi pump, according to the operating conditions, were checked. After that, the relationship with the flow rate of the venturi pump was defined using a pressure sensor corresponding to a low-cost sensor. Finally, an analysis of the estimation error was performed using the developed flow estimation logic.

Core Circuit Technologies for PN-Diode-Cell PRAM

  • Kang, Hee-Bok;Hong, Suk-Kyoung;Hong, Sung-Joo;Sung, Man-Young;Choi, Bok-Gil;Chung, Jin-Yong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권2호
    • /
    • pp.128-133
    • /
    • 2008
  • Phase-change random access memory (PRAM) chip cell phase of amorphous state is rapidly changed to crystal state above 160 Celsius degree within several seconds during Infrared (IR) reflow. Thus, on-board programming method is considered for PRAM chip programming. We demonstrated the functional 512Mb PRAM with 90nm technology using several novel core circuits, such as metal-2 line based global row decoding scheme, PN-diode cells based BL discharge (BLDIS) scheme, and PMOS switch based column decoding scheme. The reverse-state standby current of each PRAM cell is near 10 pA range. The total leak current of 512Mb PRAM chip in standby mode on discharging state can be more than 5 mA. Thus in the proposed BLDIS control, all bitlines (BLs) are in floating state in standby mode, then in active mode, the activated BLs are discharged to low level in the early timing of the active period by the short pulse BLDIS control timing operation. In the conventional sense amplifier, the simultaneous switching activation timing operation invokes the large coupling noise between the VSAREF node and the inner amplification nodes of the sense amplifiers. The coupling noise at VSAREF degrades the sensing voltage margin of the conventional sense amplifier. The merit of the proposed sense amplifier is almost removing the coupling noise at VSAREF from sharing with other sense amplifiers.

하이브리드 통신을 이용한 항로표지의 원격관리 제어시스템에 관한 연구 (A Study on the Tele-controller System of Navigational Aids Using Hybrid Communication)

  • 전중성;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.842-848
    • /
    • 2011
  • 다중통신을 지원하는 하이브리드 통신 제어보드는 저전력의 8-bit 마이크로콘트롤러인 ATxmega128A1으로 설계하였으며, 마이크로콘트롤러는 다중통신을 위한 모뎀과 GPS 모듈 등을 시리얼 인터페이스 하기 위한 8개의 UART 포트가 갖추어져 있으며, 내부에 2K 바이트의 프로그램 매개변수와 프로그램이 동작하는데 필요한 데이터를 저장할 수 있는 EEPROM과 128K 바이트의 플래시 메모리 및 프로그램이 실행되는 8K 바이트의 SRAM으로 구성되어 있다. 항로표지의 원격 관리를 CDMA, TRS, RF 등 하이브리드 통신을 이용하면 개별 통신 방식별로 음영지역이 존재하는 경우에도, 최적의 통신방식을 선택하여 통신을 수행하게 됨으로써, 통신 음영지역의 해소가 가능하다. 또한 통신장치마다 동일한 데이터 프레임을 사용함으로써 데이터의 호환성을 높였다. 실험은 30일 동안 각 부표에서 매 5분마다 데이터를 취득하였으며, 데이터 수신율은 85 % 이상을 보였다.

초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출 (Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography)

  • 조재완;서용칠;정승호;김승호;정현규
    • 한국세라믹학회지
    • /
    • 제43권4호
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.