• 제목/요약/키워드: Short circuit time

검색결과 395건 처리시간 0.026초

계통변화를 고려한 자율 적응형 과전류 계전기 (Autonomous Adaptive Digital Over Current Relay)

  • 윤준석;최면송;이승재;현승호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.444-449
    • /
    • 2003
  • In this paper present Autonomous Adaptive Digital Over Current Relay for distribution networks which acts autonomous setting using the short circuit impedance measured by relay of power systems. Automation of relay setting is one of the basic requirements for distribution automation, although manual relay setting is used at present. The short circuit impedance from a power source in distribution networks essential for the Autonomous Relay Setting changes frequently in distribution networks. In this paper the short circuit impedance is calculated with voltage and current measured in real time operation of digital relay using the Recursive Least Squares. A new method of digital relay setting is introduced using the the short circuit impedance and load current.

CD 스터드 용접의 해석 및 결함 분석 Part 2 : 기공 제어

  • 오현석;유중돈
    • Journal of Welding and Joining
    • /
    • 제24권3호
    • /
    • pp.42-48
    • /
    • 2006
  • Since the voids occur at the CD stud welds, the mechanism of void formation and void reduction method are investigated in this work. It is speculated that the voids are formed because of high short-circuit current above 1000A. When the simple flow model is used to estimate the void trapping condition, the most voids are trapped at the weld mainly due to fast cooling rate of the CD stud weld. Since it is almost impossible to remove the voids completely, a method is proposed to reduce the void by decreasing the short-circuit current at the end of the arcing time. The experimental results show that the void is reduced by decreasing the short-circuit current to 1000A.

A Novel AC Solid-State Circuit Breaker with Reclosing and Rebreaking Capability

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1074-1084
    • /
    • 2015
  • These days, the widespread use of sensitive loads and distributed generators makes the solid-state circuit breaker (SSCB) an essential component in power circuits to achieve a high power quality for AC Grids. In traditional AC SSCB using SCRs, some auxiliary mechanical devices are required to make the reclosing operation possible before fault recovery. However, the proposed AC SSCB can break quickly and then be reclosed without auxiliary mechanical devices even during the short-circuit fault. Moreover, its fault current breaking time is short and its SSCB reclosing operation is fast. This results in a reduction of the economic losses due to fault currents and power outages. Through simulations and experiments on short-circuit faults, the performance characteristics of the proposed AC SSCB are verified. A design guideline is also suggested to apply the proposed AC SSCB to various AC grids.

버스트 모드 광 신호 수신을 위한 자동 이득제어 회로 (An Automatic Gain Control Circuit for Burst-mode Optical Signal reception)

  • 기현철
    • 대한전자공학회논문지SD
    • /
    • 제40권12호
    • /
    • pp.31-38
    • /
    • 2003
  • 본 논문에서는 클리퍼(clipper)의 고속 동작 특성을 활용하여 자동 이득제어 회로의 정착시간(settling time)을 극히 짧게 구현할 수 있는 새로운 구조의 자동 이득제어 회로를 제안하였다. 제안한 자동 이득제어 회로에 대해서 해석적으로. 동작특성을 분석했다. 아울러 상용 파운드리(foundry)를 이용하여 1.2Gbps EPON 시스템용 버스트 모드 전치증폭회로를 설계하여 그 특성을 해석 결과와 비교 검증했다. 설계된 회로의 특성은 해석 결과와 잘 일치했으며 1㎱ 이하의 극히 짧은 정착시간(settling time)이 구현되고 있음을 확인 할 수 있었다

멀티레벨 PWM ac/dc 컨버터의 향상된 단락보호기법 해석 (Analysis of An Improved Short-circuit Protection for Multilevel PWM ac/dc Converter)

  • 강성관;노의철;김인동;조철제;전태원;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.193-196
    • /
    • 2001
  • This paper describes an improved short-circuit protection for a multilevel ac/dc power converter The output do power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. Once the fault has been cleared the dc power is reapplied to the load. The rising time of the do load voltage is as small as several hundred microseconds, and there is no overshoot of the dc voltage because the do output capacitors hold undischarged state. Therefore, the proposed converter can be used for a power supply, which requires a rapid disconnection of the load from the power supply in the case of a short circuit, as well as a rapid connection the load to the power supply after the clearance of the short circuit condition.

  • PDF

저압차단기의 차단보호협조 특성연구 (A study of coordination under short-circuit conditions between circuit-breakers)

  • 오준식;나칠봉;함길호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.476-478
    • /
    • 2001
  • Coordination under short-circuit conditions is a systematic application of protective devices in the electrical power system, which, in response to a fault, will remove only a minimum amount of equipment from service. The objective is not only to minimize the equipment damage and process outage costs, but also to protect personnel from the effects of these failures. The coordination study of an electric power system consists of an organizes time-current study of all devices in series from the utilization device to the source. This study is a comparison of the time it takes the individual devices to operate when certain levels of normal or abnormal current pass through the protective devices. The objective of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices that will ensure that the minimum unfaulted load is interrupted when the protective devices isolate a fault or overload anywhere in the system. At the same time, the devices and settings selected should provide satisfactory protection against overloads on the equipment and interrupt short-circuit as rapidly as possible.

  • PDF

$CO_2$용접시 Spatter발생에 미치는 Ti의 영향 (Effect of Ti on Spatter Generation of $CO_2$Welding)

  • 안영호;이종봉;방국수;엄동석
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.106-112
    • /
    • 1996
  • The effects of Ti addition in welding wire on the spatter generation and the droplet transfer phenomena were investigated. With increasing Ti content the spattering rate was decreased but the ratio of large size spatter (D $\geq$ 1. 0mm) was increased in both short circuit and globular transfer mode of $CO_2$welding. In short circuit transfer region, the arcing time was increased and the droplet transfer frequency was decreased with increasing Ti content In globular transfer region, the transition current and voltage to globular transfer was lowered and the welding condition region for stable globular transfer was widened with increasing Ti content.

  • PDF

MAG용접의 스패터 발생 및 용적이행현상에 미치는 S의 영향 (Effect of S on Spatter Generation and Droplet Transfer Phenomena of MAG Welding)

  • 안영호;이종봉;최원규
    • Journal of Welding and Joining
    • /
    • 제19권5호
    • /
    • pp.486-491
    • /
    • 2001
  • The effect of S content in welding wires on spattering characteristics and droplet transfer phenomena was studied. In MAG welding using 80%Ar-$20%CO_2$ shielding gas, spattering characteristics and droplet transfer phenomena were varied with S content of wire. Sulfur addition in wire reduced surface tension of droplet and weld pool, and made arc more stable in MAG welding. With increasing S content, the spattering ratio and the ratio of large size spatter ($d{\geq}1.0mm$) were reduced in short circuit transfer mode. In spray transfer mode, spattering ratio, however was increased when sulfur was added more than 0.020wt.% because surface tension of droplets and weld pool was reduced too much even though arc stability was improved.

  • PDF

GMAW 용적이행 현상에 미치는 Ca의 영향 (Effect of Ca on Droplet Transfer Phenomena in GMA Welding)

  • 안영호;방국수;이종봉;장내웅
    • Journal of Welding and Joining
    • /
    • 제12권4호
    • /
    • pp.76-84
    • /
    • 1994
  • Droplet transfer modes due to welding conditions and the effect of Ca in welding wire on droplet transfer were investigated. Droplet transfer mode in CO$_{2}$ welding was classified into 2 modes, that is, short circuit and globular transfer, with increasing welding current and voltage. With increasing Ca content in wire, repulsive pressure due to vaporization of Ca was considerably increased. In short circuit transfer region, arcing time was increased and droplet transfer cycle was decreased, with increasing Ca content. In globular transfer region, welding condition for globular transfer was lower current region, with increasing Ca content.

  • PDF

겹치기이음에서 용접선 시각 추적 시스템에 관한 연구 (A study on vision seam tracking system at lap joints)

  • 신정식;김재웅;나석주;최칠룡
    • Journal of Welding and Joining
    • /
    • 제9권2호
    • /
    • pp.20-28
    • /
    • 1991
  • The main subject of this study is the construction of an automatic welding system that has the capability to trace the weld seam in GMA welding of lap joints. The system was composed of a vision sensor, moving torch, and personal computer(IBM-PC). In the developed vision sensor, an image was captured by the frame grabber at the time of short circuit during welding. The threshold method was adopted for determining the structured light and the central difference method for detecting the weld joint. And the seam tracing of the torch was performed by using the data regeneration algorithm. In this system using the image at the time of short circuit, weld seam tracking was performed without any relations to arc light and spatters.

  • PDF